Cargando…

Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy

PURPOSE: To characterize intraocular pressure (IOP) dynamics by identifying the sources of transient IOP fluctuations and quantifying the frequency, magnitude, associated cumulative IOP-related mechanical energy, and temporal distribution. METHODS: IOP was monitored at 500 Hz for periods of 16 to 45...

Descripción completa

Detalles Bibliográficos
Autores principales: Turner, Daniel C., Edmiston, Anna M., Zohner, Ye Emma, Byrne, Kevin J., Seigfreid, William P., Girkin, Christopher A., Morris, Jeffrey S., Downs, J. Crawford
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6586078/
https://www.ncbi.nlm.nih.gov/pubmed/31212310
http://dx.doi.org/10.1167/iovs.19-26600
_version_ 1783428835058909184
author Turner, Daniel C.
Edmiston, Anna M.
Zohner, Ye Emma
Byrne, Kevin J.
Seigfreid, William P.
Girkin, Christopher A.
Morris, Jeffrey S.
Downs, J. Crawford
author_facet Turner, Daniel C.
Edmiston, Anna M.
Zohner, Ye Emma
Byrne, Kevin J.
Seigfreid, William P.
Girkin, Christopher A.
Morris, Jeffrey S.
Downs, J. Crawford
author_sort Turner, Daniel C.
collection PubMed
description PURPOSE: To characterize intraocular pressure (IOP) dynamics by identifying the sources of transient IOP fluctuations and quantifying the frequency, magnitude, associated cumulative IOP-related mechanical energy, and temporal distribution. METHODS: IOP was monitored at 500 Hz for periods of 16 to 451 days in nine normal eyes of six conscious, unrestrained nonhuman primates using a validated, fully implanted wireless telemetry system. IOP transducers were calibrated every two weeks via anterior chamber cannulation manometry. Analysis of time-synchronized, high-definition video was used to identify the sources of transient IOP fluctuations. RESULTS: The distribution of IOP in individual eyes is broad, and changes at multiple timescales, from second-to-second to day-to-day. Transient IOP fluctuations arise from blinks, saccades, and ocular pulse amplitude and were as high as 14 mm Hg (>100%) above momentary baseline. Transient IOP fluctuations occur ∼10,000 times per waking hour, with ∼2000 to 5000 fluctuations per hour greater than 5 mm Hg (∼40%) above baseline. Transient IOP fluctuations account for up to 17% (mean of 12%) of the total cumulative IOP-related mechanical energy that the eye must withstand during waking hours. CONCLUSIONS: Transient IOP fluctuations occur frequently and comprise a large and significant portion of the total IOP loading in the eye and should, therefore, be considered in future studies of cell mechanotransduction, ocular biomechanics, and/or clinical outcomes where transient IOP fluctuations may be important. If IOP dynamics are similar in humans, clinical snapshot IOP measurements are insufficient to capture true IOP.
format Online
Article
Text
id pubmed-6586078
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-65860782019-06-26 Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy Turner, Daniel C. Edmiston, Anna M. Zohner, Ye Emma Byrne, Kevin J. Seigfreid, William P. Girkin, Christopher A. Morris, Jeffrey S. Downs, J. Crawford Invest Ophthalmol Vis Sci Glaucoma PURPOSE: To characterize intraocular pressure (IOP) dynamics by identifying the sources of transient IOP fluctuations and quantifying the frequency, magnitude, associated cumulative IOP-related mechanical energy, and temporal distribution. METHODS: IOP was monitored at 500 Hz for periods of 16 to 451 days in nine normal eyes of six conscious, unrestrained nonhuman primates using a validated, fully implanted wireless telemetry system. IOP transducers were calibrated every two weeks via anterior chamber cannulation manometry. Analysis of time-synchronized, high-definition video was used to identify the sources of transient IOP fluctuations. RESULTS: The distribution of IOP in individual eyes is broad, and changes at multiple timescales, from second-to-second to day-to-day. Transient IOP fluctuations arise from blinks, saccades, and ocular pulse amplitude and were as high as 14 mm Hg (>100%) above momentary baseline. Transient IOP fluctuations occur ∼10,000 times per waking hour, with ∼2000 to 5000 fluctuations per hour greater than 5 mm Hg (∼40%) above baseline. Transient IOP fluctuations account for up to 17% (mean of 12%) of the total cumulative IOP-related mechanical energy that the eye must withstand during waking hours. CONCLUSIONS: Transient IOP fluctuations occur frequently and comprise a large and significant portion of the total IOP loading in the eye and should, therefore, be considered in future studies of cell mechanotransduction, ocular biomechanics, and/or clinical outcomes where transient IOP fluctuations may be important. If IOP dynamics are similar in humans, clinical snapshot IOP measurements are insufficient to capture true IOP. The Association for Research in Vision and Ophthalmology 2019-06 /pmc/articles/PMC6586078/ /pubmed/31212310 http://dx.doi.org/10.1167/iovs.19-26600 Text en Copyright 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Glaucoma
Turner, Daniel C.
Edmiston, Anna M.
Zohner, Ye Emma
Byrne, Kevin J.
Seigfreid, William P.
Girkin, Christopher A.
Morris, Jeffrey S.
Downs, J. Crawford
Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy
title Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy
title_full Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy
title_fullStr Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy
title_full_unstemmed Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy
title_short Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy
title_sort transient intraocular pressure fluctuations: source, magnitude, frequency, and associated mechanical energy
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6586078/
https://www.ncbi.nlm.nih.gov/pubmed/31212310
http://dx.doi.org/10.1167/iovs.19-26600
work_keys_str_mv AT turnerdanielc transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT edmistonannam transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT zohneryeemma transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT byrnekevinj transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT seigfreidwilliamp transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT girkinchristophera transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT morrisjeffreys transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy
AT downsjcrawford transientintraocularpressurefluctuationssourcemagnitudefrequencyandassociatedmechanicalenergy