Cargando…
Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors
The work describes the development of a flexible, hydrogel embedded pH-sensor that can be integrated in inexpensive wearable and non-invasive devices at epidermal level for electrochemical quantification of H(+) ions in sweat. Such a device can be useful for swift, real time diagnosis and for monito...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6586619/ https://www.ncbi.nlm.nih.gov/pubmed/31222160 http://dx.doi.org/10.1038/s41598-019-45399-2 |
_version_ | 1783428910509195264 |
---|---|
author | Diculescu, Victor C. Beregoi, Mihaela Evanghelidis, Alexandru Negrea, Raluca F. Apostol, Nicoleta G. Enculescu, Ionut |
author_facet | Diculescu, Victor C. Beregoi, Mihaela Evanghelidis, Alexandru Negrea, Raluca F. Apostol, Nicoleta G. Enculescu, Ionut |
author_sort | Diculescu, Victor C. |
collection | PubMed |
description | The work describes the development of a flexible, hydrogel embedded pH-sensor that can be integrated in inexpensive wearable and non-invasive devices at epidermal level for electrochemical quantification of H(+) ions in sweat. Such a device can be useful for swift, real time diagnosis and for monitoring specific conditions. The sensors’ working electrodes are flexible poly(methyl methacrylate) electrospun fibers coated with a thin gold layer and electrochemically functionalized with nanostructured palladium/palladium oxide. The response to H(+) ions is investigated by cyclic voltammetry and electrochemical impedance spectroscopy while open circuit potential measurements show a sensitivity of aprox. −59 mV per pH unit. The modification of the sensing interface upon basic and acid treatment is characterized by scanning and transmission electron microscopy and the chemical composition by X-ray photoelectron spectroscopy. In order to demonstrate the functionality of the pH-sensor at epidermal level, as a wearable device, the palladium/palladium oxide working electrode and silver/silver chloride reference electrode are embedded within a pad of polyacrylamide hydrogel and measurements in artificial sweat over a broad pH range were performed. Sensitivity up to −28 mV/pH unit, response time below 30 s, temperature dependence of approx. 1 mV/°C as well as the minimum volume to which the sensor responses of 250 nanoliters were obtained for this device. The proposed configuration represents a viable alternative making use of low-cost and fast fabrication processes and materials. |
format | Online Article Text |
id | pubmed-6586619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-65866192019-06-26 Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors Diculescu, Victor C. Beregoi, Mihaela Evanghelidis, Alexandru Negrea, Raluca F. Apostol, Nicoleta G. Enculescu, Ionut Sci Rep Article The work describes the development of a flexible, hydrogel embedded pH-sensor that can be integrated in inexpensive wearable and non-invasive devices at epidermal level for electrochemical quantification of H(+) ions in sweat. Such a device can be useful for swift, real time diagnosis and for monitoring specific conditions. The sensors’ working electrodes are flexible poly(methyl methacrylate) electrospun fibers coated with a thin gold layer and electrochemically functionalized with nanostructured palladium/palladium oxide. The response to H(+) ions is investigated by cyclic voltammetry and electrochemical impedance spectroscopy while open circuit potential measurements show a sensitivity of aprox. −59 mV per pH unit. The modification of the sensing interface upon basic and acid treatment is characterized by scanning and transmission electron microscopy and the chemical composition by X-ray photoelectron spectroscopy. In order to demonstrate the functionality of the pH-sensor at epidermal level, as a wearable device, the palladium/palladium oxide working electrode and silver/silver chloride reference electrode are embedded within a pad of polyacrylamide hydrogel and measurements in artificial sweat over a broad pH range were performed. Sensitivity up to −28 mV/pH unit, response time below 30 s, temperature dependence of approx. 1 mV/°C as well as the minimum volume to which the sensor responses of 250 nanoliters were obtained for this device. The proposed configuration represents a viable alternative making use of low-cost and fast fabrication processes and materials. Nature Publishing Group UK 2019-06-20 /pmc/articles/PMC6586619/ /pubmed/31222160 http://dx.doi.org/10.1038/s41598-019-45399-2 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Diculescu, Victor C. Beregoi, Mihaela Evanghelidis, Alexandru Negrea, Raluca F. Apostol, Nicoleta G. Enculescu, Ionut Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors |
title | Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors |
title_full | Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors |
title_fullStr | Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors |
title_full_unstemmed | Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors |
title_short | Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors |
title_sort | palladium/palladium oxide coated electrospun fibers for wearable sweat ph-sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6586619/ https://www.ncbi.nlm.nih.gov/pubmed/31222160 http://dx.doi.org/10.1038/s41598-019-45399-2 |
work_keys_str_mv | AT diculescuvictorc palladiumpalladiumoxidecoatedelectrospunfibersforwearablesweatphsensors AT beregoimihaela palladiumpalladiumoxidecoatedelectrospunfibersforwearablesweatphsensors AT evanghelidisalexandru palladiumpalladiumoxidecoatedelectrospunfibersforwearablesweatphsensors AT negrearalucaf palladiumpalladiumoxidecoatedelectrospunfibersforwearablesweatphsensors AT apostolnicoletag palladiumpalladiumoxidecoatedelectrospunfibersforwearablesweatphsensors AT enculescuionut palladiumpalladiumoxidecoatedelectrospunfibersforwearablesweatphsensors |