Cargando…

Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls

BACKGROUND: Auditory steady-state response (ASSR) paradigms have consistently demonstrated gamma band abnormalities in schizophrenia at a 40-Hz driving frequency with both electroencephalography (EEG) and magnetoencephalography (MEG). Various time-frequency measures have been used to assess the 40-H...

Descripción completa

Detalles Bibliográficos
Autores principales: Roach, Brian J., D'Souza, Deepak Cyril, Ford, Judith M., Mathalon, Daniel H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6587022/
https://www.ncbi.nlm.nih.gov/pubmed/31228795
http://dx.doi.org/10.1016/j.nicl.2019.101878
_version_ 1783428991100649472
author Roach, Brian J.
D'Souza, Deepak Cyril
Ford, Judith M.
Mathalon, Daniel H.
author_facet Roach, Brian J.
D'Souza, Deepak Cyril
Ford, Judith M.
Mathalon, Daniel H.
author_sort Roach, Brian J.
collection PubMed
description BACKGROUND: Auditory steady-state response (ASSR) paradigms have consistently demonstrated gamma band abnormalities in schizophrenia at a 40-Hz driving frequency with both electroencephalography (EEG) and magnetoencephalography (MEG). Various time-frequency measures have been used to assess the 40-Hz ASSR, including evoked power, single trial total power, phase-locking factor (PLF), and phase-locking angle (PLA). While both EEG and MEG studies have shown power and PLF ASSR measures to exhibit excellent test-retest reliability in healthy adults, the reliability of these measures in patients with schizophrenia has not been determined. METHODS: ASSRs were obtained by recording EEG data during presentation of repeated 20-Hz, 30-Hz and 40-Hz auditory click trains from nine schizophrenia patients (SZ) and nine healthy controls (HC) tested on two occasions. Similar ASSR data were collected from a separate group of 30 HC on two to three test occasions. A subset of these HC subjects had EEG recordings during two tasks, passively listening and actively attending to click train stimuli. Evoked power, total power, PLF, and PLA were calculated following Morlet wavelet time-frequency decomposition of EEG data and test-retest generalizability (G) coefficients were calculated for each ASSR condition, time-frequency measure, and subject group. RESULTS: G-coefficients ranged from good to excellent (> 0.6) for most 40-Hz time-frequency measures and participant groups, whereas 20-Hz G-coefficients were much more variable. Importantly, test-retest reliability was excellent for the various 40-Hz ASSR measures in SZ, similar to reliabilities in HC. Active attention to click train stimuli modestly reduced G-coefficients in HC relative to the passive listening condition. DISCUSSION: The excellent test-retest reliability of 40-Hz ASSR measures replicates previous EEG and MEG studies. PLA, a relatively new time-frequency measure, was shown for the first time to have excellent reliability, comparable to power and PLF measures. Excellent reliability of 40 Hz ASSR measures in SZ supports their use in clinical trials and longitudinal observational studies.
format Online
Article
Text
id pubmed-6587022
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65870222019-06-27 Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls Roach, Brian J. D'Souza, Deepak Cyril Ford, Judith M. Mathalon, Daniel H. Neuroimage Clin Regular Article BACKGROUND: Auditory steady-state response (ASSR) paradigms have consistently demonstrated gamma band abnormalities in schizophrenia at a 40-Hz driving frequency with both electroencephalography (EEG) and magnetoencephalography (MEG). Various time-frequency measures have been used to assess the 40-Hz ASSR, including evoked power, single trial total power, phase-locking factor (PLF), and phase-locking angle (PLA). While both EEG and MEG studies have shown power and PLF ASSR measures to exhibit excellent test-retest reliability in healthy adults, the reliability of these measures in patients with schizophrenia has not been determined. METHODS: ASSRs were obtained by recording EEG data during presentation of repeated 20-Hz, 30-Hz and 40-Hz auditory click trains from nine schizophrenia patients (SZ) and nine healthy controls (HC) tested on two occasions. Similar ASSR data were collected from a separate group of 30 HC on two to three test occasions. A subset of these HC subjects had EEG recordings during two tasks, passively listening and actively attending to click train stimuli. Evoked power, total power, PLF, and PLA were calculated following Morlet wavelet time-frequency decomposition of EEG data and test-retest generalizability (G) coefficients were calculated for each ASSR condition, time-frequency measure, and subject group. RESULTS: G-coefficients ranged from good to excellent (> 0.6) for most 40-Hz time-frequency measures and participant groups, whereas 20-Hz G-coefficients were much more variable. Importantly, test-retest reliability was excellent for the various 40-Hz ASSR measures in SZ, similar to reliabilities in HC. Active attention to click train stimuli modestly reduced G-coefficients in HC relative to the passive listening condition. DISCUSSION: The excellent test-retest reliability of 40-Hz ASSR measures replicates previous EEG and MEG studies. PLA, a relatively new time-frequency measure, was shown for the first time to have excellent reliability, comparable to power and PLF measures. Excellent reliability of 40 Hz ASSR measures in SZ supports their use in clinical trials and longitudinal observational studies. Elsevier 2019-06-05 /pmc/articles/PMC6587022/ /pubmed/31228795 http://dx.doi.org/10.1016/j.nicl.2019.101878 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Regular Article
Roach, Brian J.
D'Souza, Deepak Cyril
Ford, Judith M.
Mathalon, Daniel H.
Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
title Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
title_full Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
title_fullStr Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
title_full_unstemmed Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
title_short Test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
title_sort test-retest reliability of time-frequency measures of auditory steady-state responses in patients with schizophrenia and healthy controls
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6587022/
https://www.ncbi.nlm.nih.gov/pubmed/31228795
http://dx.doi.org/10.1016/j.nicl.2019.101878
work_keys_str_mv AT roachbrianj testretestreliabilityoftimefrequencymeasuresofauditorysteadystateresponsesinpatientswithschizophreniaandhealthycontrols
AT dsouzadeepakcyril testretestreliabilityoftimefrequencymeasuresofauditorysteadystateresponsesinpatientswithschizophreniaandhealthycontrols
AT fordjudithm testretestreliabilityoftimefrequencymeasuresofauditorysteadystateresponsesinpatientswithschizophreniaandhealthycontrols
AT mathalondanielh testretestreliabilityoftimefrequencymeasuresofauditorysteadystateresponsesinpatientswithschizophreniaandhealthycontrols