Highly sensitive and rapid determination of tacrolimus in peripheral blood mononuclear cells by liquid chromatography–tandem mass spectrometry

After solid organ transplantation, tacrolimus is given to prevent rejection. Therapeutic drug monitoring is used to reach target concentrations of tacrolimus in whole blood. Because the site of action of tacrolimus is the lymphocyte, and tacrolimus binds ~80% to erythrocytes, the intracellular tacro...

Descripción completa

Detalles Bibliográficos
Autores principales: Bahmany, Soma, de Wit, Lucia E.A., Hesselink, Dennis A., van Gelder, Teun, Shuker, Nauras M., Baan, Carla, van der Nagel, Bart C.H., Koch, Birgit C.P., de Winter, Brenda C.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6587946/
https://www.ncbi.nlm.nih.gov/pubmed/30362145
http://dx.doi.org/10.1002/bmc.4416
Descripción
Sumario:After solid organ transplantation, tacrolimus is given to prevent rejection. Therapeutic drug monitoring is used to reach target concentrations of tacrolimus in whole blood. Because the site of action of tacrolimus is the lymphocyte, and tacrolimus binds ~80% to erythrocytes, the intracellular tacrolimus concentration in lymphocytes is possibly more relevant. For this purpose, we aimed to develop, improve and validate a UPLC–MS/MS method to measure tacrolimus concentrations in isolated peripheral blood mononuclear cells (PBMCs). PBMCs were isolated using a Ficoll separation technique, followed by a washing step using red blood cell lysis. A cell suspension of 50 μL containing 1 million PBMCs was used in combination with MagSiMUS‐TDM(PREP). To each sample we added 30 μL lysis buffer, 20 μL reconstitution buffer containing (13)C(2)H(4)‐tacrolimus as internal standard, 40 μL MagSiMUS‐TDM(PREP) Type I Particle Mix and 175 μL Organic Precipitation Reagent VI for methanol‐based protein precipitation. A 10 μL aliquot of the supernatant was injected into the UPLC–MS/MS system. The method was validated, resulting in high sensitivity and specificity. The method was linear (r (2) = 0.997) over the range 5.0–1250 pg/1 × 10(6) PBMCs. The inaccuracy was <5% and the imprecision was <15%. The washing steps following Ficoll isolation could be performed at either room temperature or on ice, with no effect of the temperature on the results. A method for the analysis of tacrolimus concentrations in PBMCs was developed and successfully validated. Further research will be performed to investigate the correlation between concentrations in PBMCs and clinical outcome.