Cargando…

Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert

Ultrahigh-resolution, low-dose rescans in a region of interest following a general screening computed tomography (CT) scan is motivated by the need to reduce invasive tissue biopsy procedures in cancer screening. We describe a new method to meet the conflicting demands of ultrahigh resolution, high-...

Descripción completa

Detalles Bibliográficos
Autores principales: Larsen, Thomas C., Bennett, Eric E., Mazilu, Dumitru, Chen, Marcus Y., Wen, Han
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Grapho Publications, LLC 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6588199/
https://www.ncbi.nlm.nih.gov/pubmed/31245544
http://dx.doi.org/10.18383/j.tom.2019.00002
_version_ 1783429206122692608
author Larsen, Thomas C.
Bennett, Eric E.
Mazilu, Dumitru
Chen, Marcus Y.
Wen, Han
author_facet Larsen, Thomas C.
Bennett, Eric E.
Mazilu, Dumitru
Chen, Marcus Y.
Wen, Han
author_sort Larsen, Thomas C.
collection PubMed
description Ultrahigh-resolution, low-dose rescans in a region of interest following a general screening computed tomography (CT) scan is motivated by the need to reduce invasive tissue biopsy procedures in cancer screening. We describe a new method to meet the conflicting demands of ultrahigh resolution, high-speed and ultralow-dose, and the first proof-of-concept experiment. With improving detector resolution, the limiting factor for the system resolution of whole-body CT scanners shifts to the penumbra of the source focal spot. The penumbra unsharpness is minimized by inserting flat-panel detector(s) that are in direct contact with the body. In the hybrid system, the detector insert and the CT detector acquire data simultaneously, whereby the standard CT images give the position and orientation of the detector insert(s) as needed for tomosynthesis reconstruction. Imaging tests were performed with a compact photon-counting detector insert on resolution targets of both high- and low-contrast as well as a mouse specimen, all inside a body phantom. Detector insert tomosynthesis provided twice the resolution of the CT scanner alone at the same dose concentration. The short 2-cm beam collimation of the tomosynthesis rescan gave an effective dose equivalent to 6% of an average CT scan in the chest or abdomen.
format Online
Article
Text
id pubmed-6588199
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Grapho Publications, LLC
record_format MEDLINE/PubMed
spelling pubmed-65881992019-06-26 Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert Larsen, Thomas C. Bennett, Eric E. Mazilu, Dumitru Chen, Marcus Y. Wen, Han Tomography Advances in Brief Ultrahigh-resolution, low-dose rescans in a region of interest following a general screening computed tomography (CT) scan is motivated by the need to reduce invasive tissue biopsy procedures in cancer screening. We describe a new method to meet the conflicting demands of ultrahigh resolution, high-speed and ultralow-dose, and the first proof-of-concept experiment. With improving detector resolution, the limiting factor for the system resolution of whole-body CT scanners shifts to the penumbra of the source focal spot. The penumbra unsharpness is minimized by inserting flat-panel detector(s) that are in direct contact with the body. In the hybrid system, the detector insert and the CT detector acquire data simultaneously, whereby the standard CT images give the position and orientation of the detector insert(s) as needed for tomosynthesis reconstruction. Imaging tests were performed with a compact photon-counting detector insert on resolution targets of both high- and low-contrast as well as a mouse specimen, all inside a body phantom. Detector insert tomosynthesis provided twice the resolution of the CT scanner alone at the same dose concentration. The short 2-cm beam collimation of the tomosynthesis rescan gave an effective dose equivalent to 6% of an average CT scan in the chest or abdomen. Grapho Publications, LLC 2019-06 /pmc/articles/PMC6588199/ /pubmed/31245544 http://dx.doi.org/10.18383/j.tom.2019.00002 Text en © 2019 The Authors. Published by Grapho Publications, LLC http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Advances in Brief
Larsen, Thomas C.
Bennett, Eric E.
Mazilu, Dumitru
Chen, Marcus Y.
Wen, Han
Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
title Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
title_full Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
title_fullStr Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
title_full_unstemmed Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
title_short Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
title_sort regional ultrahigh-resolution rescan in a clinical whole-body ct scanner using a contact detector insert
topic Advances in Brief
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6588199/
https://www.ncbi.nlm.nih.gov/pubmed/31245544
http://dx.doi.org/10.18383/j.tom.2019.00002
work_keys_str_mv AT larsenthomasc regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert
AT bennetterice regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert
AT maziludumitru regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert
AT chenmarcusy regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert
AT wenhan regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert