Cargando…
Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert
Ultrahigh-resolution, low-dose rescans in a region of interest following a general screening computed tomography (CT) scan is motivated by the need to reduce invasive tissue biopsy procedures in cancer screening. We describe a new method to meet the conflicting demands of ultrahigh resolution, high-...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Grapho Publications, LLC
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6588199/ https://www.ncbi.nlm.nih.gov/pubmed/31245544 http://dx.doi.org/10.18383/j.tom.2019.00002 |
_version_ | 1783429206122692608 |
---|---|
author | Larsen, Thomas C. Bennett, Eric E. Mazilu, Dumitru Chen, Marcus Y. Wen, Han |
author_facet | Larsen, Thomas C. Bennett, Eric E. Mazilu, Dumitru Chen, Marcus Y. Wen, Han |
author_sort | Larsen, Thomas C. |
collection | PubMed |
description | Ultrahigh-resolution, low-dose rescans in a region of interest following a general screening computed tomography (CT) scan is motivated by the need to reduce invasive tissue biopsy procedures in cancer screening. We describe a new method to meet the conflicting demands of ultrahigh resolution, high-speed and ultralow-dose, and the first proof-of-concept experiment. With improving detector resolution, the limiting factor for the system resolution of whole-body CT scanners shifts to the penumbra of the source focal spot. The penumbra unsharpness is minimized by inserting flat-panel detector(s) that are in direct contact with the body. In the hybrid system, the detector insert and the CT detector acquire data simultaneously, whereby the standard CT images give the position and orientation of the detector insert(s) as needed for tomosynthesis reconstruction. Imaging tests were performed with a compact photon-counting detector insert on resolution targets of both high- and low-contrast as well as a mouse specimen, all inside a body phantom. Detector insert tomosynthesis provided twice the resolution of the CT scanner alone at the same dose concentration. The short 2-cm beam collimation of the tomosynthesis rescan gave an effective dose equivalent to 6% of an average CT scan in the chest or abdomen. |
format | Online Article Text |
id | pubmed-6588199 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Grapho Publications, LLC |
record_format | MEDLINE/PubMed |
spelling | pubmed-65881992019-06-26 Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert Larsen, Thomas C. Bennett, Eric E. Mazilu, Dumitru Chen, Marcus Y. Wen, Han Tomography Advances in Brief Ultrahigh-resolution, low-dose rescans in a region of interest following a general screening computed tomography (CT) scan is motivated by the need to reduce invasive tissue biopsy procedures in cancer screening. We describe a new method to meet the conflicting demands of ultrahigh resolution, high-speed and ultralow-dose, and the first proof-of-concept experiment. With improving detector resolution, the limiting factor for the system resolution of whole-body CT scanners shifts to the penumbra of the source focal spot. The penumbra unsharpness is minimized by inserting flat-panel detector(s) that are in direct contact with the body. In the hybrid system, the detector insert and the CT detector acquire data simultaneously, whereby the standard CT images give the position and orientation of the detector insert(s) as needed for tomosynthesis reconstruction. Imaging tests were performed with a compact photon-counting detector insert on resolution targets of both high- and low-contrast as well as a mouse specimen, all inside a body phantom. Detector insert tomosynthesis provided twice the resolution of the CT scanner alone at the same dose concentration. The short 2-cm beam collimation of the tomosynthesis rescan gave an effective dose equivalent to 6% of an average CT scan in the chest or abdomen. Grapho Publications, LLC 2019-06 /pmc/articles/PMC6588199/ /pubmed/31245544 http://dx.doi.org/10.18383/j.tom.2019.00002 Text en © 2019 The Authors. Published by Grapho Publications, LLC http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Advances in Brief Larsen, Thomas C. Bennett, Eric E. Mazilu, Dumitru Chen, Marcus Y. Wen, Han Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert |
title | Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert |
title_full | Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert |
title_fullStr | Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert |
title_full_unstemmed | Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert |
title_short | Regional Ultrahigh-Resolution Rescan in a Clinical Whole-Body CT Scanner Using a Contact Detector Insert |
title_sort | regional ultrahigh-resolution rescan in a clinical whole-body ct scanner using a contact detector insert |
topic | Advances in Brief |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6588199/ https://www.ncbi.nlm.nih.gov/pubmed/31245544 http://dx.doi.org/10.18383/j.tom.2019.00002 |
work_keys_str_mv | AT larsenthomasc regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert AT bennetterice regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert AT maziludumitru regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert AT chenmarcusy regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert AT wenhan regionalultrahighresolutionrescaninaclinicalwholebodyctscannerusingacontactdetectorinsert |