Cargando…

Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study

OBJECTIVE: The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent. MATERIALS-METHODS: For both microhard...

Descripción completa

Detalles Bibliográficos
Autores principales: Özduman, Zümrüt Ceren, Kazak, Magrur, Fildisi, Mehmet Ali, Özlen, Rümeysa Hatice, Dalkilic, Evrim, Donmez, Nazmiye
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6589237/
https://www.ncbi.nlm.nih.gov/pubmed/31281561
http://dx.doi.org/10.1155/2019/2307305
_version_ 1783429360318939136
author Özduman, Zümrüt Ceren
Kazak, Magrur
Fildisi, Mehmet Ali
Özlen, Rümeysa Hatice
Dalkilic, Evrim
Donmez, Nazmiye
author_facet Özduman, Zümrüt Ceren
Kazak, Magrur
Fildisi, Mehmet Ali
Özlen, Rümeysa Hatice
Dalkilic, Evrim
Donmez, Nazmiye
author_sort Özduman, Zümrüt Ceren
collection PubMed
description OBJECTIVE: The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent. MATERIALS-METHODS: For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n = 5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n = 12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey's HSD test. The data from the top surface of specimens' microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-Whitney U tests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p < 0.05). RESULTS: The B/T microhardness ratio results revealed no significant differences between groups (p > 0.05). Comparing the microhardness values of the composites' top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p < 0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p > 0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p < 0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p < 0.05). CONCLUSION: The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment.
format Online
Article
Text
id pubmed-6589237
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-65892372019-07-07 Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study Özduman, Zümrüt Ceren Kazak, Magrur Fildisi, Mehmet Ali Özlen, Rümeysa Hatice Dalkilic, Evrim Donmez, Nazmiye Scanning Research Article OBJECTIVE: The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent. MATERIALS-METHODS: For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n = 5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n = 12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey's HSD test. The data from the top surface of specimens' microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-Whitney U tests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p < 0.05). RESULTS: The B/T microhardness ratio results revealed no significant differences between groups (p > 0.05). Comparing the microhardness values of the composites' top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p < 0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p > 0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p < 0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p < 0.05). CONCLUSION: The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment. Hindawi 2019-06-02 /pmc/articles/PMC6589237/ /pubmed/31281561 http://dx.doi.org/10.1155/2019/2307305 Text en Copyright © 2019 Zümrüt Ceren Özduman et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Özduman, Zümrüt Ceren
Kazak, Magrur
Fildisi, Mehmet Ali
Özlen, Rümeysa Hatice
Dalkilic, Evrim
Donmez, Nazmiye
Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study
title Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study
title_full Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study
title_fullStr Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study
title_full_unstemmed Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study
title_short Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites: A Scanning Electron Microscopy Study
title_sort effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: a scanning electron microscopy study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6589237/
https://www.ncbi.nlm.nih.gov/pubmed/31281561
http://dx.doi.org/10.1155/2019/2307305
work_keys_str_mv AT ozdumanzumrutceren effectofpolymerizationtimeandhomebleachingagentonthemicrohardnessandsurfaceroughnessofbulkfillcompositesascanningelectronmicroscopystudy
AT kazakmagrur effectofpolymerizationtimeandhomebleachingagentonthemicrohardnessandsurfaceroughnessofbulkfillcompositesascanningelectronmicroscopystudy
AT fildisimehmetali effectofpolymerizationtimeandhomebleachingagentonthemicrohardnessandsurfaceroughnessofbulkfillcompositesascanningelectronmicroscopystudy
AT ozlenrumeysahatice effectofpolymerizationtimeandhomebleachingagentonthemicrohardnessandsurfaceroughnessofbulkfillcompositesascanningelectronmicroscopystudy
AT dalkilicevrim effectofpolymerizationtimeandhomebleachingagentonthemicrohardnessandsurfaceroughnessofbulkfillcompositesascanningelectronmicroscopystudy
AT donmeznazmiye effectofpolymerizationtimeandhomebleachingagentonthemicrohardnessandsurfaceroughnessofbulkfillcompositesascanningelectronmicroscopystudy