Cargando…

Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device

Isolation and detection of circulating tumor cells (CTCs) from human blood plays an important role in non- invasive screening of cancer evolution and in predictive therapeutic treatment. Here, we present the novel tool utilizing: (i) the microfluidic device with (ii) incorporated photovoltaic (PV) b...

Descripción completa

Detalles Bibliográficos
Autores principales: Niciński, K., Krajczewski, J., Kudelski, A., Witkowska, E., Trzcińska-Danielewicz, J., Girstun, A., Kamińska, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6592934/
https://www.ncbi.nlm.nih.gov/pubmed/31239487
http://dx.doi.org/10.1038/s41598-019-45629-7
_version_ 1783429948614115328
author Niciński, K.
Krajczewski, J.
Kudelski, A.
Witkowska, E.
Trzcińska-Danielewicz, J.
Girstun, A.
Kamińska, A.
author_facet Niciński, K.
Krajczewski, J.
Kudelski, A.
Witkowska, E.
Trzcińska-Danielewicz, J.
Girstun, A.
Kamińska, A.
author_sort Niciński, K.
collection PubMed
description Isolation and detection of circulating tumor cells (CTCs) from human blood plays an important role in non- invasive screening of cancer evolution and in predictive therapeutic treatment. Here, we present the novel tool utilizing: (i) the microfluidic device with (ii) incorporated photovoltaic (PV) based SERS-active platform, and (iii) shell-isolated nanoparticles (SHINs) for simultaneous separation and label-free analysis of circulating tumour cells CTCs in the blood specimens with high specificity and sensitivity. The proposed microfluidic chip enables the efficient size – based inertial separation of circulating cancer cells from the whole blood samples. The SERS-active platform incorporated into the microfluidic device permits the label-free detection and identification of isolated cells through the insight into their molecular and biochemical structure. Additionally, the silver nanoparticles coated with an ultrathin shell of silica (Ag@SiO(2)) was used to improve the detection accuracy and sensitivity of analysed tumor cells via taking advantages of shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS). The empirical analysis of SHINERS spectra revealed that there are some differences among studied (HeLa), renal cell carcinoma (Caki-1), and blood cells. Unique SHINERS features and differences in bands intensities between healthy and cancer cells might be associated with the variations in the quantity and quality of molecules such as lipid, protein, and DNA or their structure during the metastasis cancer formation. To demonstrate the statistical efficiency of the developed method and improve the differentiation for circulating tumors cells detection the principal component analysis (PCA) has been performed for all SHINERS data. PCA method has been applied to recognize the most significant differences in SHINERS data among the three analyzed cells: Caki-1, HeLa, and blood cells. The proposed approach challenges the current multi-steps CTCs detection methods in the terms of simplicity, sensitivity, invasiveness, destructivity, time and cost of analysis, and also prevents the defragmentation/damage of tumor cells and thus leads to improving the accuracy of analysis. The results of this research work show the potential of developed SERS based tool for the separation of tumor cells from whole blood samples in a simple and minimally invasive manner, their detection and molecular characterization using one single technology.
format Online
Article
Text
id pubmed-6592934
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-65929342019-07-03 Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device Niciński, K. Krajczewski, J. Kudelski, A. Witkowska, E. Trzcińska-Danielewicz, J. Girstun, A. Kamińska, A. Sci Rep Article Isolation and detection of circulating tumor cells (CTCs) from human blood plays an important role in non- invasive screening of cancer evolution and in predictive therapeutic treatment. Here, we present the novel tool utilizing: (i) the microfluidic device with (ii) incorporated photovoltaic (PV) based SERS-active platform, and (iii) shell-isolated nanoparticles (SHINs) for simultaneous separation and label-free analysis of circulating tumour cells CTCs in the blood specimens with high specificity and sensitivity. The proposed microfluidic chip enables the efficient size – based inertial separation of circulating cancer cells from the whole blood samples. The SERS-active platform incorporated into the microfluidic device permits the label-free detection and identification of isolated cells through the insight into their molecular and biochemical structure. Additionally, the silver nanoparticles coated with an ultrathin shell of silica (Ag@SiO(2)) was used to improve the detection accuracy and sensitivity of analysed tumor cells via taking advantages of shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS). The empirical analysis of SHINERS spectra revealed that there are some differences among studied (HeLa), renal cell carcinoma (Caki-1), and blood cells. Unique SHINERS features and differences in bands intensities between healthy and cancer cells might be associated with the variations in the quantity and quality of molecules such as lipid, protein, and DNA or their structure during the metastasis cancer formation. To demonstrate the statistical efficiency of the developed method and improve the differentiation for circulating tumors cells detection the principal component analysis (PCA) has been performed for all SHINERS data. PCA method has been applied to recognize the most significant differences in SHINERS data among the three analyzed cells: Caki-1, HeLa, and blood cells. The proposed approach challenges the current multi-steps CTCs detection methods in the terms of simplicity, sensitivity, invasiveness, destructivity, time and cost of analysis, and also prevents the defragmentation/damage of tumor cells and thus leads to improving the accuracy of analysis. The results of this research work show the potential of developed SERS based tool for the separation of tumor cells from whole blood samples in a simple and minimally invasive manner, their detection and molecular characterization using one single technology. Nature Publishing Group UK 2019-06-25 /pmc/articles/PMC6592934/ /pubmed/31239487 http://dx.doi.org/10.1038/s41598-019-45629-7 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Niciński, K.
Krajczewski, J.
Kudelski, A.
Witkowska, E.
Trzcińska-Danielewicz, J.
Girstun, A.
Kamińska, A.
Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device
title Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device
title_full Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device
title_fullStr Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device
title_full_unstemmed Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device
title_short Detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced Raman spectroscopy (SHINERS) in microfluidic device
title_sort detection of circulating tumor cells in blood by shell-isolated nanoparticle – enhanced raman spectroscopy (shiners) in microfluidic device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6592934/
https://www.ncbi.nlm.nih.gov/pubmed/31239487
http://dx.doi.org/10.1038/s41598-019-45629-7
work_keys_str_mv AT nicinskik detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice
AT krajczewskij detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice
AT kudelskia detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice
AT witkowskae detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice
AT trzcinskadanielewiczj detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice
AT girstuna detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice
AT kaminskaa detectionofcirculatingtumorcellsinbloodbyshellisolatednanoparticleenhancedramanspectroscopyshinersinmicrofluidicdevice