Cargando…

A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem

BACKGROUND: Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill rati...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacquel, Alexandre, Le Viguelloux, Augustin, Valluy, Jeremy, Saffarini, Mo, Bonin, Nicolas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593034/
https://www.ncbi.nlm.nih.gov/pubmed/31240502
http://dx.doi.org/10.1186/s40634-019-0197-1
_version_ 1783429961407791104
author Jacquel, Alexandre
Le Viguelloux, Augustin
Valluy, Jeremy
Saffarini, Mo
Bonin, Nicolas
author_facet Jacquel, Alexandre
Le Viguelloux, Augustin
Valluy, Jeremy
Saffarini, Mo
Bonin, Nicolas
author_sort Jacquel, Alexandre
collection PubMed
description BACKGROUND: Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill ratio (CFR) and axial alignment of a shortened double-tapered stem with those of a standard stem. The hypothesis was that the shortened stem would achieve greater metaphyseal fill and comparable axial alignment. METHODS: The authors reviewed routine follow-up anteroposterior radiographs taken 2 months after THA to evaluate metaphyseal fill and axial alignment of a shortened stem (n = 96) and a standard stem (n = 101). The CFR was calculated at the level of the tip and superior margin of the lesser trochanter. Stem alignment was defined as the angle between the stem axis and the proximal anatomic femoral axis. Stems were classified as being in varus or valgus alignment if they deviated by more than 3° from the anatomic axis of the femur. RESULTS: Hips implanted with shortened and standard stems had comparable demographics and axial alignment (1.1° ± 1.7° vs 0.8° ± 1.2°; p = 0.331). However, varus alignment was observed in 5% of shortened stems compared to only 1% of standard stems, though this difference was not significant (p = 0.111). The femoral CFR was greater using shortened stems than using standard stems, both at the level of the tip of the lesser trochanter (0.91 ± 0.05 vs 0.85 ± 0.08; p < 0.001) and at its superior margin (0.76 ± 0.06 vs 0.72 ± 0.07; p < 0.001). CONCLUSIONS: Compared to the standard stem, the shortened stem had increased metaphyseal filling and equivalent alignment. These findings suggest that shortened stems could provide adequate metaphyseal fixation and correct alignment. Further studies remain necessary to evaluate how shortened stems perform in terms of osseointegration, clinical outcomes and survival.
format Online
Article
Text
id pubmed-6593034
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-65930342019-07-11 A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem Jacquel, Alexandre Le Viguelloux, Augustin Valluy, Jeremy Saffarini, Mo Bonin, Nicolas J Exp Orthop Research BACKGROUND: Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill ratio (CFR) and axial alignment of a shortened double-tapered stem with those of a standard stem. The hypothesis was that the shortened stem would achieve greater metaphyseal fill and comparable axial alignment. METHODS: The authors reviewed routine follow-up anteroposterior radiographs taken 2 months after THA to evaluate metaphyseal fill and axial alignment of a shortened stem (n = 96) and a standard stem (n = 101). The CFR was calculated at the level of the tip and superior margin of the lesser trochanter. Stem alignment was defined as the angle between the stem axis and the proximal anatomic femoral axis. Stems were classified as being in varus or valgus alignment if they deviated by more than 3° from the anatomic axis of the femur. RESULTS: Hips implanted with shortened and standard stems had comparable demographics and axial alignment (1.1° ± 1.7° vs 0.8° ± 1.2°; p = 0.331). However, varus alignment was observed in 5% of shortened stems compared to only 1% of standard stems, though this difference was not significant (p = 0.111). The femoral CFR was greater using shortened stems than using standard stems, both at the level of the tip of the lesser trochanter (0.91 ± 0.05 vs 0.85 ± 0.08; p < 0.001) and at its superior margin (0.76 ± 0.06 vs 0.72 ± 0.07; p < 0.001). CONCLUSIONS: Compared to the standard stem, the shortened stem had increased metaphyseal filling and equivalent alignment. These findings suggest that shortened stems could provide adequate metaphyseal fixation and correct alignment. Further studies remain necessary to evaluate how shortened stems perform in terms of osseointegration, clinical outcomes and survival. Springer Berlin Heidelberg 2019-06-25 /pmc/articles/PMC6593034/ /pubmed/31240502 http://dx.doi.org/10.1186/s40634-019-0197-1 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Jacquel, Alexandre
Le Viguelloux, Augustin
Valluy, Jeremy
Saffarini, Mo
Bonin, Nicolas
A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
title A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
title_full A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
title_fullStr A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
title_full_unstemmed A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
title_short A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
title_sort shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593034/
https://www.ncbi.nlm.nih.gov/pubmed/31240502
http://dx.doi.org/10.1186/s40634-019-0197-1
work_keys_str_mv AT jacquelalexandre ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT leviguellouxaugustin ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT valluyjeremy ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT saffarinimo ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT boninnicolas ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT jacquelalexandre shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT leviguellouxaugustin shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT valluyjeremy shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT saffarinimo shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem
AT boninnicolas shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem