Cargando…
A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem
BACKGROUND: Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill rati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593034/ https://www.ncbi.nlm.nih.gov/pubmed/31240502 http://dx.doi.org/10.1186/s40634-019-0197-1 |
_version_ | 1783429961407791104 |
---|---|
author | Jacquel, Alexandre Le Viguelloux, Augustin Valluy, Jeremy Saffarini, Mo Bonin, Nicolas |
author_facet | Jacquel, Alexandre Le Viguelloux, Augustin Valluy, Jeremy Saffarini, Mo Bonin, Nicolas |
author_sort | Jacquel, Alexandre |
collection | PubMed |
description | BACKGROUND: Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill ratio (CFR) and axial alignment of a shortened double-tapered stem with those of a standard stem. The hypothesis was that the shortened stem would achieve greater metaphyseal fill and comparable axial alignment. METHODS: The authors reviewed routine follow-up anteroposterior radiographs taken 2 months after THA to evaluate metaphyseal fill and axial alignment of a shortened stem (n = 96) and a standard stem (n = 101). The CFR was calculated at the level of the tip and superior margin of the lesser trochanter. Stem alignment was defined as the angle between the stem axis and the proximal anatomic femoral axis. Stems were classified as being in varus or valgus alignment if they deviated by more than 3° from the anatomic axis of the femur. RESULTS: Hips implanted with shortened and standard stems had comparable demographics and axial alignment (1.1° ± 1.7° vs 0.8° ± 1.2°; p = 0.331). However, varus alignment was observed in 5% of shortened stems compared to only 1% of standard stems, though this difference was not significant (p = 0.111). The femoral CFR was greater using shortened stems than using standard stems, both at the level of the tip of the lesser trochanter (0.91 ± 0.05 vs 0.85 ± 0.08; p < 0.001) and at its superior margin (0.76 ± 0.06 vs 0.72 ± 0.07; p < 0.001). CONCLUSIONS: Compared to the standard stem, the shortened stem had increased metaphyseal filling and equivalent alignment. These findings suggest that shortened stems could provide adequate metaphyseal fixation and correct alignment. Further studies remain necessary to evaluate how shortened stems perform in terms of osseointegration, clinical outcomes and survival. |
format | Online Article Text |
id | pubmed-6593034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-65930342019-07-11 A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem Jacquel, Alexandre Le Viguelloux, Augustin Valluy, Jeremy Saffarini, Mo Bonin, Nicolas J Exp Orthop Research BACKGROUND: Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill ratio (CFR) and axial alignment of a shortened double-tapered stem with those of a standard stem. The hypothesis was that the shortened stem would achieve greater metaphyseal fill and comparable axial alignment. METHODS: The authors reviewed routine follow-up anteroposterior radiographs taken 2 months after THA to evaluate metaphyseal fill and axial alignment of a shortened stem (n = 96) and a standard stem (n = 101). The CFR was calculated at the level of the tip and superior margin of the lesser trochanter. Stem alignment was defined as the angle between the stem axis and the proximal anatomic femoral axis. Stems were classified as being in varus or valgus alignment if they deviated by more than 3° from the anatomic axis of the femur. RESULTS: Hips implanted with shortened and standard stems had comparable demographics and axial alignment (1.1° ± 1.7° vs 0.8° ± 1.2°; p = 0.331). However, varus alignment was observed in 5% of shortened stems compared to only 1% of standard stems, though this difference was not significant (p = 0.111). The femoral CFR was greater using shortened stems than using standard stems, both at the level of the tip of the lesser trochanter (0.91 ± 0.05 vs 0.85 ± 0.08; p < 0.001) and at its superior margin (0.76 ± 0.06 vs 0.72 ± 0.07; p < 0.001). CONCLUSIONS: Compared to the standard stem, the shortened stem had increased metaphyseal filling and equivalent alignment. These findings suggest that shortened stems could provide adequate metaphyseal fixation and correct alignment. Further studies remain necessary to evaluate how shortened stems perform in terms of osseointegration, clinical outcomes and survival. Springer Berlin Heidelberg 2019-06-25 /pmc/articles/PMC6593034/ /pubmed/31240502 http://dx.doi.org/10.1186/s40634-019-0197-1 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Jacquel, Alexandre Le Viguelloux, Augustin Valluy, Jeremy Saffarini, Mo Bonin, Nicolas A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
title | A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
title_full | A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
title_fullStr | A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
title_full_unstemmed | A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
title_short | A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
title_sort | shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593034/ https://www.ncbi.nlm.nih.gov/pubmed/31240502 http://dx.doi.org/10.1186/s40634-019-0197-1 |
work_keys_str_mv | AT jacquelalexandre ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT leviguellouxaugustin ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT valluyjeremy ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT saffarinimo ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT boninnicolas ashorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT jacquelalexandre shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT leviguellouxaugustin shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT valluyjeremy shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT saffarinimo shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem AT boninnicolas shorteneduncementedstemofferscomparablepositioningandincreasedmetaphysealfillcomparedtoastandarduncementedstem |