Cargando…
Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions
Both transesophageal echocardiography (TEE) and intracardiac echocardiography have been used to assist transvenous lead extractions. The clinical utility of continuous echocardiographic monitoring during the procedure is still debated, with different reports supporting opposite findings. In cases wh...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593712/ https://www.ncbi.nlm.nih.gov/pubmed/30905087 http://dx.doi.org/10.1111/echo.14318 |
_version_ | 1783430107095891968 |
---|---|
author | Strachinaru, Mihai Kievit, Chris M. Yap, Sing C. Hirsch, Alexander Geleijnse, Marcel L. Szili‐Torok, Tamas |
author_facet | Strachinaru, Mihai Kievit, Chris M. Yap, Sing C. Hirsch, Alexander Geleijnse, Marcel L. Szili‐Torok, Tamas |
author_sort | Strachinaru, Mihai |
collection | PubMed |
description | Both transesophageal echocardiography (TEE) and intracardiac echocardiography have been used to assist transvenous lead extractions. The clinical utility of continuous echocardiographic monitoring during the procedure is still debated, with different reports supporting opposite findings. In cases where the procedure is expected to be difficult, we propose adding a continuous TEE monitoring using a static 3D/multiplane probe in mid‐esophageal position, with digital remote manipulation of the field of view. This approach may improve the chances of a successful extraction, increase safety, or even guide the entire intervention. We present here a short case series where continuous monitoring by TEE played an important role. |
format | Online Article Text |
id | pubmed-6593712 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65937122019-07-10 Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions Strachinaru, Mihai Kievit, Chris M. Yap, Sing C. Hirsch, Alexander Geleijnse, Marcel L. Szili‐Torok, Tamas Echocardiography CHALLENGING CASES Section Editor ‐ Natesa Pandian, MD Both transesophageal echocardiography (TEE) and intracardiac echocardiography have been used to assist transvenous lead extractions. The clinical utility of continuous echocardiographic monitoring during the procedure is still debated, with different reports supporting opposite findings. In cases where the procedure is expected to be difficult, we propose adding a continuous TEE monitoring using a static 3D/multiplane probe in mid‐esophageal position, with digital remote manipulation of the field of view. This approach may improve the chances of a successful extraction, increase safety, or even guide the entire intervention. We present here a short case series where continuous monitoring by TEE played an important role. John Wiley and Sons Inc. 2019-03-24 2019-05 /pmc/articles/PMC6593712/ /pubmed/30905087 http://dx.doi.org/10.1111/echo.14318 Text en © 2019 The Authors. Echocardiography Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | CHALLENGING CASES Section Editor ‐ Natesa Pandian, MD Strachinaru, Mihai Kievit, Chris M. Yap, Sing C. Hirsch, Alexander Geleijnse, Marcel L. Szili‐Torok, Tamas Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
title | Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
title_full | Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
title_fullStr | Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
title_full_unstemmed | Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
title_short | Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
title_sort | multiplane/3d transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions |
topic | CHALLENGING CASES Section Editor ‐ Natesa Pandian, MD |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593712/ https://www.ncbi.nlm.nih.gov/pubmed/30905087 http://dx.doi.org/10.1111/echo.14318 |
work_keys_str_mv | AT strachinarumihai multiplane3dtransesophagealechocardiographymonitoringtoimprovethesafetyandoutcomeofcomplextransvenousleadextractions AT kievitchrism multiplane3dtransesophagealechocardiographymonitoringtoimprovethesafetyandoutcomeofcomplextransvenousleadextractions AT yapsingc multiplane3dtransesophagealechocardiographymonitoringtoimprovethesafetyandoutcomeofcomplextransvenousleadextractions AT hirschalexander multiplane3dtransesophagealechocardiographymonitoringtoimprovethesafetyandoutcomeofcomplextransvenousleadextractions AT geleijnsemarcell multiplane3dtransesophagealechocardiographymonitoringtoimprovethesafetyandoutcomeofcomplextransvenousleadextractions AT szilitoroktamas multiplane3dtransesophagealechocardiographymonitoringtoimprovethesafetyandoutcomeofcomplextransvenousleadextractions |