Cargando…
In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity
Current pharmaceutical therapies can reduce hip fractures by up to 50%, but compliance to treatment is low and therapies take up to 18 months to reduce risk. Thus, alternative or complementary approaches to reduce the risk of hip fracture are needed. The AGN1 local osteo‐enhancement procedure (LOEP)...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593990/ https://www.ncbi.nlm.nih.gov/pubmed/30793358 http://dx.doi.org/10.1002/jor.24239 |
_version_ | 1783430167061856256 |
---|---|
author | Stroncek, John D. Shaul, Jonathan L. Favell, Dominique Hill, Ronald S. Huber, Bryan M. Howe, James G. Bouxsein, Mary L. |
author_facet | Stroncek, John D. Shaul, Jonathan L. Favell, Dominique Hill, Ronald S. Huber, Bryan M. Howe, James G. Bouxsein, Mary L. |
author_sort | Stroncek, John D. |
collection | PubMed |
description | Current pharmaceutical therapies can reduce hip fractures by up to 50%, but compliance to treatment is low and therapies take up to 18 months to reduce risk. Thus, alternative or complementary approaches to reduce the risk of hip fracture are needed. The AGN1 local osteo‐enhancement procedure (LOEP) is one such alternative approach, as it is designed to locally replace bone lost due to osteoporosis and provide immediate biomechanical benefit. This in vitro study evaluated the initial biomechanical impact of this treatment on human cadaveric femurs. We obtained 45 pairs of cadaveric femurs from women aged 77.8 ± 8.8 years. One femur of each pair was treated, while the contralateral femur served as an untreated control. Treatment included debridement, irrigation/suction, and injection of a triphasic calcium‐based implant (AGN1). Mechanical testing of the femora was performed in a sideways fall configuration 24 h after treatment. Of the 45 pairs, 4 had normal, 16 osteopenic, and 25 osteoporotic BMD T‐scores. Altogether, treatment increased failure load on average by 20.5% (p < 0.0001). In the subset of osteoporotic femurs, treatment increased failure load by 26% and work to failure by 45% (p < 0.01 for both). Treatment did not significantly affect stiffness in any group. These findings provide evidence that local delivery of the triphasic calcium‐based implant in the proximal femur is technically feasible and provides immediate biomechanical benefit. Our results provide strong rationale for additional studies investigating the utility of this approach for reducing the risk of hip fracture. © 2019 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. |
format | Online Article Text |
id | pubmed-6593990 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65939902019-07-10 In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity Stroncek, John D. Shaul, Jonathan L. Favell, Dominique Hill, Ronald S. Huber, Bryan M. Howe, James G. Bouxsein, Mary L. J Orthop Res Research Articles Current pharmaceutical therapies can reduce hip fractures by up to 50%, but compliance to treatment is low and therapies take up to 18 months to reduce risk. Thus, alternative or complementary approaches to reduce the risk of hip fracture are needed. The AGN1 local osteo‐enhancement procedure (LOEP) is one such alternative approach, as it is designed to locally replace bone lost due to osteoporosis and provide immediate biomechanical benefit. This in vitro study evaluated the initial biomechanical impact of this treatment on human cadaveric femurs. We obtained 45 pairs of cadaveric femurs from women aged 77.8 ± 8.8 years. One femur of each pair was treated, while the contralateral femur served as an untreated control. Treatment included debridement, irrigation/suction, and injection of a triphasic calcium‐based implant (AGN1). Mechanical testing of the femora was performed in a sideways fall configuration 24 h after treatment. Of the 45 pairs, 4 had normal, 16 osteopenic, and 25 osteoporotic BMD T‐scores. Altogether, treatment increased failure load on average by 20.5% (p < 0.0001). In the subset of osteoporotic femurs, treatment increased failure load by 26% and work to failure by 45% (p < 0.01 for both). Treatment did not significantly affect stiffness in any group. These findings provide evidence that local delivery of the triphasic calcium‐based implant in the proximal femur is technically feasible and provides immediate biomechanical benefit. Our results provide strong rationale for additional studies investigating the utility of this approach for reducing the risk of hip fracture. © 2019 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. John Wiley and Sons Inc. 2019-03-20 2019-04 /pmc/articles/PMC6593990/ /pubmed/30793358 http://dx.doi.org/10.1002/jor.24239 Text en © 2019 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Stroncek, John D. Shaul, Jonathan L. Favell, Dominique Hill, Ronald S. Huber, Bryan M. Howe, James G. Bouxsein, Mary L. In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
title | In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
title_full | In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
title_fullStr | In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
title_full_unstemmed | In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
title_short | In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
title_sort | in vitro injection of osteoporotic cadaveric femurs with a triphasic calcium‐based implant confers immediate biomechanical integrity |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593990/ https://www.ncbi.nlm.nih.gov/pubmed/30793358 http://dx.doi.org/10.1002/jor.24239 |
work_keys_str_mv | AT stroncekjohnd invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity AT shauljonathanl invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity AT favelldominique invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity AT hillronalds invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity AT huberbryanm invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity AT howejamesg invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity AT bouxseinmaryl invitroinjectionofosteoporoticcadavericfemurswithatriphasiccalciumbasedimplantconfersimmediatebiomechanicalintegrity |