Cargando…
Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps
PURPOSE: DWI is a promising modality in breast MRI, but its clinical acceptance is slow. Analysis of DWI is hampered by geometric distortion artifacts, which are caused by off‐resonant spins in combination with the low phase‐encoding bandwidth of the EPI sequence used. Existing correction methods as...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593992/ https://www.ncbi.nlm.nih.gov/pubmed/30825245 http://dx.doi.org/10.1002/mrm.27701 |
_version_ | 1783430167529521152 |
---|---|
author | van Rijssel, Michael J. Zijlstra, Frank Seevinck, Peter R. Luijten, Peter R. Gilhuijs, Kenneth G. A. Klomp, Dennis W. J. Pluim, Josien P. W. |
author_facet | van Rijssel, Michael J. Zijlstra, Frank Seevinck, Peter R. Luijten, Peter R. Gilhuijs, Kenneth G. A. Klomp, Dennis W. J. Pluim, Josien P. W. |
author_sort | van Rijssel, Michael J. |
collection | PubMed |
description | PURPOSE: DWI is a promising modality in breast MRI, but its clinical acceptance is slow. Analysis of DWI is hampered by geometric distortion artifacts, which are caused by off‐resonant spins in combination with the low phase‐encoding bandwidth of the EPI sequence used. Existing correction methods assume smooth off‐resonance fields, which we show to be invalid in the human breast, where high discontinuities arise at tissue interfaces. METHODS: We developed a distortion correction method that incorporates high‐resolution off‐resonance maps to better solve for severe distortions at tissue interfaces. The method was evaluated quantitatively both ex vivo in a porcine tissue phantom and in vivo in 5 healthy volunteers. The added value of high‐resolution off‐resonance maps was tested using a Wilcoxon signed rank test comparing the quantitative results obtained with a low‐resolution off‐resonance map with those obtained with a high‐resolution map. RESULTS: Distortion correction using low‐resolution off‐resonance maps corrected most of the distortions, as expected. Still, all quantitative comparison metrics showed increased conformity between the corrected EPI images and a high‐bandwidth reference scan for both the ex vivo and in vivo experiments. All metrics showed a significant improvement when a high‐resolution off‐resonance map was used (P < 0.05), in particular at tissue boundaries. CONCLUSION: The use of off‐resonance maps of a resolution higher than EPI scans significantly improves upon existing distortion correction techniques, specifically by superior correction at glandular tissue boundaries. |
format | Online Article Text |
id | pubmed-6593992 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65939922019-07-10 Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps van Rijssel, Michael J. Zijlstra, Frank Seevinck, Peter R. Luijten, Peter R. Gilhuijs, Kenneth G. A. Klomp, Dennis W. J. Pluim, Josien P. W. Magn Reson Med Full Papers—Computer Processing and Modeling PURPOSE: DWI is a promising modality in breast MRI, but its clinical acceptance is slow. Analysis of DWI is hampered by geometric distortion artifacts, which are caused by off‐resonant spins in combination with the low phase‐encoding bandwidth of the EPI sequence used. Existing correction methods assume smooth off‐resonance fields, which we show to be invalid in the human breast, where high discontinuities arise at tissue interfaces. METHODS: We developed a distortion correction method that incorporates high‐resolution off‐resonance maps to better solve for severe distortions at tissue interfaces. The method was evaluated quantitatively both ex vivo in a porcine tissue phantom and in vivo in 5 healthy volunteers. The added value of high‐resolution off‐resonance maps was tested using a Wilcoxon signed rank test comparing the quantitative results obtained with a low‐resolution off‐resonance map with those obtained with a high‐resolution map. RESULTS: Distortion correction using low‐resolution off‐resonance maps corrected most of the distortions, as expected. Still, all quantitative comparison metrics showed increased conformity between the corrected EPI images and a high‐bandwidth reference scan for both the ex vivo and in vivo experiments. All metrics showed a significant improvement when a high‐resolution off‐resonance map was used (P < 0.05), in particular at tissue boundaries. CONCLUSION: The use of off‐resonance maps of a resolution higher than EPI scans significantly improves upon existing distortion correction techniques, specifically by superior correction at glandular tissue boundaries. John Wiley and Sons Inc. 2019-03-01 2019-07 /pmc/articles/PMC6593992/ /pubmed/30825245 http://dx.doi.org/10.1002/mrm.27701 Text en © 2019 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Full Papers—Computer Processing and Modeling van Rijssel, Michael J. Zijlstra, Frank Seevinck, Peter R. Luijten, Peter R. Gilhuijs, Kenneth G. A. Klomp, Dennis W. J. Pluim, Josien P. W. Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
title | Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
title_full | Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
title_fullStr | Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
title_full_unstemmed | Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
title_short | Reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
title_sort | reducing distortions in echo‐planar breast imaging at ultrahigh field with high‐resolution off‐resonance maps |
topic | Full Papers—Computer Processing and Modeling |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6593992/ https://www.ncbi.nlm.nih.gov/pubmed/30825245 http://dx.doi.org/10.1002/mrm.27701 |
work_keys_str_mv | AT vanrijsselmichaelj reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps AT zijlstrafrank reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps AT seevinckpeterr reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps AT luijtenpeterr reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps AT gilhuijskennethga reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps AT klompdenniswj reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps AT pluimjosienpw reducingdistortionsinechoplanarbreastimagingatultrahighfieldwithhighresolutionoffresonancemaps |