Cargando…
Vasodilation through levodopa for Parkinson's disease may require high left ventricular assist device flow
We report implantation of a left ventricular assist device (LVAD) in a patient with Parkinson's disease. Postoperative fluid overload together with insufficient LVAD output in the setting of vasodilation through levodopa likely caused renal hypoperfusion and acute kidney injury. A patient like...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594037/ https://www.ncbi.nlm.nih.gov/pubmed/30847947 http://dx.doi.org/10.1111/jocs.14012 |
Sumario: | We report implantation of a left ventricular assist device (LVAD) in a patient with Parkinson's disease. Postoperative fluid overload together with insufficient LVAD output in the setting of vasodilation through levodopa likely caused renal hypoperfusion and acute kidney injury. A patient like ours, therefore, requires the highest possible increase of HM3 RPM and LVAD flow early after surgery. |
---|