Cargando…

Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial

AIM: To compare the clinical performance and marginal bone levels of implants restored with platform‐switching (PS) or platform‐matching (PM) abutments. MATERIALS AND METHODS: Adult patients missing two or more adjacent teeth in the posterior mandible received 2–4 CAMLOG SCREW‐LINE implants and were...

Descripción completa

Detalles Bibliográficos
Autores principales: Messias, Ana, Rocha, Salomão, Wagner, Wilfried, Wiltfang, Jörg, Moergel, Maximilian, Behrens, Eleonore, Nicolau, Pedro, Guerra, Fernando
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594132/
https://www.ncbi.nlm.nih.gov/pubmed/31025365
http://dx.doi.org/10.1111/jcpe.13119
_version_ 1783430195876724736
author Messias, Ana
Rocha, Salomão
Wagner, Wilfried
Wiltfang, Jörg
Moergel, Maximilian
Behrens, Eleonore
Nicolau, Pedro
Guerra, Fernando
author_facet Messias, Ana
Rocha, Salomão
Wagner, Wilfried
Wiltfang, Jörg
Moergel, Maximilian
Behrens, Eleonore
Nicolau, Pedro
Guerra, Fernando
author_sort Messias, Ana
collection PubMed
description AIM: To compare the clinical performance and marginal bone levels of implants restored with platform‐switching (PS) or platform‐matching (PM) abutments. MATERIALS AND METHODS: Adult patients missing two or more adjacent teeth in the posterior mandible received 2–4 CAMLOG SCREW‐LINE implants and were randomly allocated to the PM or PS group, receiving the corresponding prosthetic components from surgery onwards. Implants were conventionally loaded with single cemented crowns. Patients were followed annually for 5 years. Outcome measures were marginal bone level changes, implant survival, performance of the prosthetic components and clinical parameters plaque index, sulcus bleeding index and pocket probing depth. RESULTS: Thirty‐three patients received 72 implants in the PM group, and thirty‐five patients received 74 implants in the PS group. Sixty patients attended the final appointment, 31 had received PS components and 29 had received PM components with 65 and 63 implants, respectively. Global survival rate was 96.6% with no differences between groups (p = 0.647). After 5 years of functional loading, PS restored implants presented 0.23mm (95% CI: [0.03, 0.43], p = 0.025) lower marginal bone level changes. The two groups were declared non‐equivalent. CONCLUSION: Patients requiring implant supported restorations in healed bounded or free end edentulous gaps of the mandible benefit from the use of PS components in terms of peri‐implant marginal bone level maintenance, though it may not be clinically noticeable.
format Online
Article
Text
id pubmed-6594132
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-65941322019-07-10 Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial Messias, Ana Rocha, Salomão Wagner, Wilfried Wiltfang, Jörg Moergel, Maximilian Behrens, Eleonore Nicolau, Pedro Guerra, Fernando J Clin Periodontol Implant Therapy AIM: To compare the clinical performance and marginal bone levels of implants restored with platform‐switching (PS) or platform‐matching (PM) abutments. MATERIALS AND METHODS: Adult patients missing two or more adjacent teeth in the posterior mandible received 2–4 CAMLOG SCREW‐LINE implants and were randomly allocated to the PM or PS group, receiving the corresponding prosthetic components from surgery onwards. Implants were conventionally loaded with single cemented crowns. Patients were followed annually for 5 years. Outcome measures were marginal bone level changes, implant survival, performance of the prosthetic components and clinical parameters plaque index, sulcus bleeding index and pocket probing depth. RESULTS: Thirty‐three patients received 72 implants in the PM group, and thirty‐five patients received 74 implants in the PS group. Sixty patients attended the final appointment, 31 had received PS components and 29 had received PM components with 65 and 63 implants, respectively. Global survival rate was 96.6% with no differences between groups (p = 0.647). After 5 years of functional loading, PS restored implants presented 0.23mm (95% CI: [0.03, 0.43], p = 0.025) lower marginal bone level changes. The two groups were declared non‐equivalent. CONCLUSION: Patients requiring implant supported restorations in healed bounded or free end edentulous gaps of the mandible benefit from the use of PS components in terms of peri‐implant marginal bone level maintenance, though it may not be clinically noticeable. John Wiley and Sons Inc. 2019-05-20 2019-06 /pmc/articles/PMC6594132/ /pubmed/31025365 http://dx.doi.org/10.1111/jcpe.13119 Text en © 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Implant Therapy
Messias, Ana
Rocha, Salomão
Wagner, Wilfried
Wiltfang, Jörg
Moergel, Maximilian
Behrens, Eleonore
Nicolau, Pedro
Guerra, Fernando
Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
title Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
title_full Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
title_fullStr Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
title_full_unstemmed Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
title_short Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
title_sort peri‐implant marginal bone loss reduction with platform‐switching components: 5‐year post‐loading results of an equivalence randomized clinical trial
topic Implant Therapy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594132/
https://www.ncbi.nlm.nih.gov/pubmed/31025365
http://dx.doi.org/10.1111/jcpe.13119
work_keys_str_mv AT messiasana periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT rochasalomao periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT wagnerwilfried periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT wiltfangjorg periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT moergelmaximilian periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT behrenseleonore periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT nicolaupedro periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial
AT guerrafernando periimplantmarginalbonelossreductionwithplatformswitchingcomponents5yearpostloadingresultsofanequivalencerandomizedclinicaltrial