Cargando…

Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis

OBJECTIVE: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures. METHODS: Three groups of finite element models of the intact pelvis, including the ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Pan, Wu, Tao, Wang, Hui‐zhi, Qi, Xin‐zheng, Yao, Jie, Cheng, Xiao‐dong, Chen, Wei, Zhang, Ying‐ze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594476/
https://www.ncbi.nlm.nih.gov/pubmed/30895703
http://dx.doi.org/10.1111/os.12431
_version_ 1783430249519775744
author Hu, Pan
Wu, Tao
Wang, Hui‐zhi
Qi, Xin‐zheng
Yao, Jie
Cheng, Xiao‐dong
Chen, Wei
Zhang, Ying‐ze
author_facet Hu, Pan
Wu, Tao
Wang, Hui‐zhi
Qi, Xin‐zheng
Yao, Jie
Cheng, Xiao‐dong
Chen, Wei
Zhang, Ying‐ze
author_sort Hu, Pan
collection PubMed
description OBJECTIVE: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures. METHODS: Three groups of finite element models of the intact pelvis, including the main ligament and the proximal one‐third of both femurs, were developed to simulate vertical sacral fractures and treated with the three abovementioned internal fixation techniques. A 500 N vertical load, a 500 N vertical load plus a 10 Nm moment of forward sagittal direction, and 500 N vertical load plus a 10 Nm moment of right lateral direction were applied to the sacrum to simulate standing status, bending status, and flexion status, respectively. The maximum displacement value, the stress value, and the stress value of the fracture interface were compared among the three internal fixation techniques. RESULTS: The results showed that all three internal fixation techniques effectively restored the biomechanical transmission of the injured pelvis. The stress on the implants in the TBP model was 167.47% and 53.41% higher than that in the ISS model and the MIAP model, respectively, and the stress shielding phenomenon of the TBP model was more obvious than in the other two models. Meanwhile, the stress between the fracture interfaces in the TBP fixation models was apparently higher than that in the other two models. However, the vertical displacement of the MIAP model was not significantly different from that in the ISS and TBP model; therefore, strong fixation could be obtained in all three models. CONCLUSION: Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels.
format Online
Article
Text
id pubmed-6594476
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-65944762019-09-10 Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis Hu, Pan Wu, Tao Wang, Hui‐zhi Qi, Xin‐zheng Yao, Jie Cheng, Xiao‐dong Chen, Wei Zhang, Ying‐ze Orthop Surg Clinical Articles OBJECTIVE: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures. METHODS: Three groups of finite element models of the intact pelvis, including the main ligament and the proximal one‐third of both femurs, were developed to simulate vertical sacral fractures and treated with the three abovementioned internal fixation techniques. A 500 N vertical load, a 500 N vertical load plus a 10 Nm moment of forward sagittal direction, and 500 N vertical load plus a 10 Nm moment of right lateral direction were applied to the sacrum to simulate standing status, bending status, and flexion status, respectively. The maximum displacement value, the stress value, and the stress value of the fracture interface were compared among the three internal fixation techniques. RESULTS: The results showed that all three internal fixation techniques effectively restored the biomechanical transmission of the injured pelvis. The stress on the implants in the TBP model was 167.47% and 53.41% higher than that in the ISS model and the MIAP model, respectively, and the stress shielding phenomenon of the TBP model was more obvious than in the other two models. Meanwhile, the stress between the fracture interfaces in the TBP fixation models was apparently higher than that in the other two models. However, the vertical displacement of the MIAP model was not significantly different from that in the ISS and TBP model; therefore, strong fixation could be obtained in all three models. CONCLUSION: Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels. John Wiley & Sons Australia, Ltd 2019-03-21 /pmc/articles/PMC6594476/ /pubmed/30895703 http://dx.doi.org/10.1111/os.12431 Text en © 2019 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Articles
Hu, Pan
Wu, Tao
Wang, Hui‐zhi
Qi, Xin‐zheng
Yao, Jie
Cheng, Xiao‐dong
Chen, Wei
Zhang, Ying‐ze
Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
title Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
title_full Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
title_fullStr Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
title_full_unstemmed Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
title_short Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
title_sort biomechanical comparison of three internal fixation techniques for stabilizing posterior pelvic ring disruption: a 3d finite element analysis
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594476/
https://www.ncbi.nlm.nih.gov/pubmed/30895703
http://dx.doi.org/10.1111/os.12431
work_keys_str_mv AT hupan biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT wutao biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT wanghuizhi biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT qixinzheng biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT yaojie biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT chengxiaodong biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT chenwei biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis
AT zhangyingze biomechanicalcomparisonofthreeinternalfixationtechniquesforstabilizingposteriorpelvicringdisruptiona3dfiniteelementanalysis