Cargando…

CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion

OBJECTIVES: A radiographic study was designed to measure the relationship of the exiting nerve root and its surroundings to the corresponding intervertebral disc for percutaneous transforaminal endoscopic lumbar interbody fusion to better understand the regional anatomy and to improve clinical appli...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Kai‐hui, Zhang, Wei‐hao, Xu, Bao‐shan, Dong, Xiao‐man, Guo, Lin, Du, Li‐long, Xu, Hai‐wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594482/
https://www.ncbi.nlm.nih.gov/pubmed/30895721
http://dx.doi.org/10.1111/os.12434
_version_ 1783430249980100608
author Zhang, Kai‐hui
Zhang, Wei‐hao
Xu, Bao‐shan
Dong, Xiao‐man
Guo, Lin
Du, Li‐long
Xu, Hai‐wei
author_facet Zhang, Kai‐hui
Zhang, Wei‐hao
Xu, Bao‐shan
Dong, Xiao‐man
Guo, Lin
Du, Li‐long
Xu, Hai‐wei
author_sort Zhang, Kai‐hui
collection PubMed
description OBJECTIVES: A radiographic study was designed to measure the relationship of the exiting nerve root and its surroundings to the corresponding intervertebral disc for percutaneous transforaminal endoscopic lumbar interbody fusion to better understand the regional anatomy and to improve clinical applications. METHODS: A retrospective study from January 2017 to October 2017 was conducted at Tianjin Hospital. CT images were obtained from patients presenting low back pain (110 patients), and analysis was performed bilaterally from L(2‐3) to L(5)S(1). In the rotating coronal plane we analyzed: the nerve root–dural sac distance at the superior and inferior margins of the disc (Js, Ji); the nerve root–pedicle distance at the medial, middle, and lateral borders of the pedicle (Pa, Pb, Pc); the pedicle width (W); and the safe working zone, defined as a trapezoid bounded by the inferior pedicle and the exiting nerve root (S). In the transverse plane, the nerve root‐articular process and the shortest distance for the nerve root‐articular process joint surface were analyzed at the superior and inferior margins of the disc (Gs, Gi), respectively. The groups were analyzed using ANOVA, and paired t‐tests were used to compare the left and right sides. RESULTS: From L(2‐3) to L(5)S(1), the distance of the nerve root to the dural sac was larger at the inferior margin of the disc. From L(2‐3) to L(5)S(1), each segment of the vertebral nerve root‐pedicle distance gradually decreased from medial to lateral. From L(2‐3) to L(5)S(1), the distance from the exiting nerve root to the middle and lateral margins of the pedicle gradually decreased, with L(5)S(1) being the minimum. Some significant differences were observed between the left and right sides for L(4‐5) and L(5)S(1). The pedicle width of the vertebral body and the mean area for the safe working zone gradually increased from L(2‐3) to L(5)S(1). In the axial plane, the shortest distance between the nerve root and articular process joint surface at the inferior margin of the disc was greater than the distance for the nerve root to the articular process at the superior margin of the disc from L(2‐3) to L(5)S(1). There were no significant differences between the two sides. CONCLUSIONS: It is more difficult to implant a cage with a width of 10 mm above the L(3‐4) level. By removing part of the superior articular process, the safe working area can be expanded, and damage to the nerve or other structures can be avoided when implanting a cage.
format Online
Article
Text
id pubmed-6594482
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-65944822019-09-10 CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion Zhang, Kai‐hui Zhang, Wei‐hao Xu, Bao‐shan Dong, Xiao‐man Guo, Lin Du, Li‐long Xu, Hai‐wei Orthop Surg Clinical Articles OBJECTIVES: A radiographic study was designed to measure the relationship of the exiting nerve root and its surroundings to the corresponding intervertebral disc for percutaneous transforaminal endoscopic lumbar interbody fusion to better understand the regional anatomy and to improve clinical applications. METHODS: A retrospective study from January 2017 to October 2017 was conducted at Tianjin Hospital. CT images were obtained from patients presenting low back pain (110 patients), and analysis was performed bilaterally from L(2‐3) to L(5)S(1). In the rotating coronal plane we analyzed: the nerve root–dural sac distance at the superior and inferior margins of the disc (Js, Ji); the nerve root–pedicle distance at the medial, middle, and lateral borders of the pedicle (Pa, Pb, Pc); the pedicle width (W); and the safe working zone, defined as a trapezoid bounded by the inferior pedicle and the exiting nerve root (S). In the transverse plane, the nerve root‐articular process and the shortest distance for the nerve root‐articular process joint surface were analyzed at the superior and inferior margins of the disc (Gs, Gi), respectively. The groups were analyzed using ANOVA, and paired t‐tests were used to compare the left and right sides. RESULTS: From L(2‐3) to L(5)S(1), the distance of the nerve root to the dural sac was larger at the inferior margin of the disc. From L(2‐3) to L(5)S(1), each segment of the vertebral nerve root‐pedicle distance gradually decreased from medial to lateral. From L(2‐3) to L(5)S(1), the distance from the exiting nerve root to the middle and lateral margins of the pedicle gradually decreased, with L(5)S(1) being the minimum. Some significant differences were observed between the left and right sides for L(4‐5) and L(5)S(1). The pedicle width of the vertebral body and the mean area for the safe working zone gradually increased from L(2‐3) to L(5)S(1). In the axial plane, the shortest distance between the nerve root and articular process joint surface at the inferior margin of the disc was greater than the distance for the nerve root to the articular process at the superior margin of the disc from L(2‐3) to L(5)S(1). There were no significant differences between the two sides. CONCLUSIONS: It is more difficult to implant a cage with a width of 10 mm above the L(3‐4) level. By removing part of the superior articular process, the safe working area can be expanded, and damage to the nerve or other structures can be avoided when implanting a cage. John Wiley & Sons Australia, Ltd 2019-03-21 /pmc/articles/PMC6594482/ /pubmed/30895721 http://dx.doi.org/10.1111/os.12434 Text en © 2019 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Articles
Zhang, Kai‐hui
Zhang, Wei‐hao
Xu, Bao‐shan
Dong, Xiao‐man
Guo, Lin
Du, Li‐long
Xu, Hai‐wei
CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion
title CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion
title_full CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion
title_fullStr CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion
title_full_unstemmed CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion
title_short CT‐based Morphometric Analysis of Approach of Percutaneous Transforaminal Endoscopic Lumbar Interbody Fusion
title_sort ct‐based morphometric analysis of approach of percutaneous transforaminal endoscopic lumbar interbody fusion
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594482/
https://www.ncbi.nlm.nih.gov/pubmed/30895721
http://dx.doi.org/10.1111/os.12434
work_keys_str_mv AT zhangkaihui ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion
AT zhangweihao ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion
AT xubaoshan ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion
AT dongxiaoman ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion
AT guolin ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion
AT dulilong ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion
AT xuhaiwei ctbasedmorphometricanalysisofapproachofpercutaneoustransforaminalendoscopiclumbarinterbodyfusion