Cargando…

Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty

OBJECTIVE: To determine the comparability among 10 radiographic anteversion methods for acetabular cup orientation in total hip arthroplasty (THA) found in the literature and the “gold” standard of assessing the anteversion with CT. METHODS: This is a retrospective study that blindly compares 10 dif...

Descripción completa

Detalles Bibliográficos
Autores principales: Snijders, Thom E, Schlösser, Tom P C, van Gaalen, Steven M, Castelein, Rene M, Weinans, Harry, de Gast, Arthur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594505/
https://www.ncbi.nlm.nih.gov/pubmed/30932341
http://dx.doi.org/10.1111/os.12445
_version_ 1783430251382046720
author Snijders, Thom E
Schlösser, Tom P C
van Gaalen, Steven M
Castelein, Rene M
Weinans, Harry
de Gast, Arthur
author_facet Snijders, Thom E
Schlösser, Tom P C
van Gaalen, Steven M
Castelein, Rene M
Weinans, Harry
de Gast, Arthur
author_sort Snijders, Thom E
collection PubMed
description OBJECTIVE: To determine the comparability among 10 radiographic anteversion methods for acetabular cup orientation in total hip arthroplasty (THA) found in the literature and the “gold” standard of assessing the anteversion with CT. METHODS: This is a retrospective study that blindly compares 10 different conventional radiographic anteversion measurements with the “gold” standard, the measurement of anteversion on the transverse plane of the 3‐D images made with CT. The patient archiving and communications system (PACS) was systematically searched for subjects that had undergone a CT angiogram of the abdomen and lower extremities, including the pelvis, had at least one THA in situ and had undergone anterior‐posterior (AP) and cross‐lateral pelvic radiography between January 2013 and August 2016 in the Diakonessenhuis Hospital Utrecht/Zeist, a non‐academic institution. CT scans of patients (n = 16) were systematically collected. Three observers independently measured cup anteversion from radiographs, using a total of 10 different methods, and measured the “gold” standard on CT images. The outcomes of the 10 radiographic anteversion were compared in terms of linear correlation with the “gold” standard on CT images. RESULTS: The correlations of the radiographic measured anteversions with the “gold” standard measured on CT images were 0.528 for the method of Liaw, 0.556 for Wan, 0.562 for the cross‐lateral method, 0.586 for Hassan, 0.594 for Dorr, 0.602 for Lewinnek, 0.624 for Widmer, 0.671 for the lateral CT, 0.747 for Ackland, and 0.771 for the method of Riten Pradham. CONCLUSION: Anteversion measurement methods represent different projectional angles of the acetabular cup in different planes around different axes. Therefore, they differ from the “gold” standard and are not interchangeable, as is shown by this study. We consider the anatomical anteversion in the transverse plane rotating around the longitudinal axis as the “gold” standard and recommend avoiding using the term anteversion for other projectional angles in different planes.
format Online
Article
Text
id pubmed-6594505
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-65945052019-09-10 Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty Snijders, Thom E Schlösser, Tom P C van Gaalen, Steven M Castelein, Rene M Weinans, Harry de Gast, Arthur Orthop Surg Clinical Articles OBJECTIVE: To determine the comparability among 10 radiographic anteversion methods for acetabular cup orientation in total hip arthroplasty (THA) found in the literature and the “gold” standard of assessing the anteversion with CT. METHODS: This is a retrospective study that blindly compares 10 different conventional radiographic anteversion measurements with the “gold” standard, the measurement of anteversion on the transverse plane of the 3‐D images made with CT. The patient archiving and communications system (PACS) was systematically searched for subjects that had undergone a CT angiogram of the abdomen and lower extremities, including the pelvis, had at least one THA in situ and had undergone anterior‐posterior (AP) and cross‐lateral pelvic radiography between January 2013 and August 2016 in the Diakonessenhuis Hospital Utrecht/Zeist, a non‐academic institution. CT scans of patients (n = 16) were systematically collected. Three observers independently measured cup anteversion from radiographs, using a total of 10 different methods, and measured the “gold” standard on CT images. The outcomes of the 10 radiographic anteversion were compared in terms of linear correlation with the “gold” standard on CT images. RESULTS: The correlations of the radiographic measured anteversions with the “gold” standard measured on CT images were 0.528 for the method of Liaw, 0.556 for Wan, 0.562 for the cross‐lateral method, 0.586 for Hassan, 0.594 for Dorr, 0.602 for Lewinnek, 0.624 for Widmer, 0.671 for the lateral CT, 0.747 for Ackland, and 0.771 for the method of Riten Pradham. CONCLUSION: Anteversion measurement methods represent different projectional angles of the acetabular cup in different planes around different axes. Therefore, they differ from the “gold” standard and are not interchangeable, as is shown by this study. We consider the anatomical anteversion in the transverse plane rotating around the longitudinal axis as the “gold” standard and recommend avoiding using the term anteversion for other projectional angles in different planes. John Wiley & Sons Australia, Ltd 2019-04-01 /pmc/articles/PMC6594505/ /pubmed/30932341 http://dx.doi.org/10.1111/os.12445 Text en © 2019 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Articles
Snijders, Thom E
Schlösser, Tom P C
van Gaalen, Steven M
Castelein, Rene M
Weinans, Harry
de Gast, Arthur
Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
title Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
title_full Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
title_fullStr Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
title_full_unstemmed Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
title_short Non‐equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
title_sort non‐equivalent results from different anteversion measurements methods for the evaluation of the acetabular cup orientation in total hip arthroplasty
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594505/
https://www.ncbi.nlm.nih.gov/pubmed/30932341
http://dx.doi.org/10.1111/os.12445
work_keys_str_mv AT snijdersthome nonequivalentresultsfromdifferentanteversionmeasurementsmethodsfortheevaluationoftheacetabularcuporientationintotalhiparthroplasty
AT schlossertompc nonequivalentresultsfromdifferentanteversionmeasurementsmethodsfortheevaluationoftheacetabularcuporientationintotalhiparthroplasty
AT vangaalenstevenm nonequivalentresultsfromdifferentanteversionmeasurementsmethodsfortheevaluationoftheacetabularcuporientationintotalhiparthroplasty
AT casteleinrenem nonequivalentresultsfromdifferentanteversionmeasurementsmethodsfortheevaluationoftheacetabularcuporientationintotalhiparthroplasty
AT weinansharry nonequivalentresultsfromdifferentanteversionmeasurementsmethodsfortheevaluationoftheacetabularcuporientationintotalhiparthroplasty
AT degastarthur nonequivalentresultsfromdifferentanteversionmeasurementsmethodsfortheevaluationoftheacetabularcuporientationintotalhiparthroplasty