Cargando…

Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses

INTRODUCTION: The desired outcome of the implantation of active middle ear implants is maximum coupling efficiency and a minimum of conductive loss. It has not been investigated yet, which loading forces are applied during the process of coupling, which forces lead to an optimum actuator performance...

Descripción completa

Detalles Bibliográficos
Autores principales: Gamm, Ute A., Grossöhmichen, Martin, Salcher, Rolf B., Prenzler, Nils K., Lenarz, Thomas, Maier, Hannes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594747/
https://www.ncbi.nlm.nih.gov/pubmed/30994569
http://dx.doi.org/10.1097/MAO.0000000000002253
_version_ 1783430289481007104
author Gamm, Ute A.
Grossöhmichen, Martin
Salcher, Rolf B.
Prenzler, Nils K.
Lenarz, Thomas
Maier, Hannes
author_facet Gamm, Ute A.
Grossöhmichen, Martin
Salcher, Rolf B.
Prenzler, Nils K.
Lenarz, Thomas
Maier, Hannes
author_sort Gamm, Ute A.
collection PubMed
description INTRODUCTION: The desired outcome of the implantation of active middle ear implants is maximum coupling efficiency and a minimum of conductive loss. It has not been investigated yet, which loading forces are applied during the process of coupling, which forces lead to an optimum actuator performance and which forces occur when manufacturer guidelines for coupling are followed. METHODS: Actuator output was measured by laser Doppler vibrometry of stapes motion while the actuator was advanced in 20 μm steps against the incus body while monitoring static contact force. The occurrence of conductive losses was investigated by measuring changes in stapes motion in response to acoustic stimulation for each step of actuator displacement. Additionally, the electrical impedance of the actuator was measured over the whole frequency range at each actuator position. RESULTS: Highest coupling efficiency was achieved at forces above 10 mN. Below 1 mN no efficient coupling could be achieved. At 30 mN loading force, which is typical when coupling according to manufacturer guidelines, conductive losses of more than 5 dB were observed in one out of nine TBs. The electrical impedance of the actuator showed a prominent resonance peak which vanished after coupling. CONCLUSION: A minimum coupling force of 10 mN is required for efficient coupling of the actuator to the incus. In most cases, coupling forces up to 100 mN will not result in clinically relevant conductive losses. The electrical impedance is a simple and reliable metric to indicate contact.
format Online
Article
Text
id pubmed-6594747
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-65947472019-07-22 Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses Gamm, Ute A. Grossöhmichen, Martin Salcher, Rolf B. Prenzler, Nils K. Lenarz, Thomas Maier, Hannes Otol Neurotol Prosthetic Devices INTRODUCTION: The desired outcome of the implantation of active middle ear implants is maximum coupling efficiency and a minimum of conductive loss. It has not been investigated yet, which loading forces are applied during the process of coupling, which forces lead to an optimum actuator performance and which forces occur when manufacturer guidelines for coupling are followed. METHODS: Actuator output was measured by laser Doppler vibrometry of stapes motion while the actuator was advanced in 20 μm steps against the incus body while monitoring static contact force. The occurrence of conductive losses was investigated by measuring changes in stapes motion in response to acoustic stimulation for each step of actuator displacement. Additionally, the electrical impedance of the actuator was measured over the whole frequency range at each actuator position. RESULTS: Highest coupling efficiency was achieved at forces above 10 mN. Below 1 mN no efficient coupling could be achieved. At 30 mN loading force, which is typical when coupling according to manufacturer guidelines, conductive losses of more than 5 dB were observed in one out of nine TBs. The electrical impedance of the actuator showed a prominent resonance peak which vanished after coupling. CONCLUSION: A minimum coupling force of 10 mN is required for efficient coupling of the actuator to the incus. In most cases, coupling forces up to 100 mN will not result in clinically relevant conductive losses. The electrical impedance is a simple and reliable metric to indicate contact. Lippincott Williams & Wilkins 2019-07 2019-04-16 /pmc/articles/PMC6594747/ /pubmed/30994569 http://dx.doi.org/10.1097/MAO.0000000000002253 Text en Copyright © 2019 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of Otology & Neurotology, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Prosthetic Devices
Gamm, Ute A.
Grossöhmichen, Martin
Salcher, Rolf B.
Prenzler, Nils K.
Lenarz, Thomas
Maier, Hannes
Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses
title Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses
title_full Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses
title_fullStr Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses
title_full_unstemmed Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses
title_short Optimum Coupling of an Active Middle Ear Actuator: Effect of Loading Forces on Actuator Output and Conductive Losses
title_sort optimum coupling of an active middle ear actuator: effect of loading forces on actuator output and conductive losses
topic Prosthetic Devices
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594747/
https://www.ncbi.nlm.nih.gov/pubmed/30994569
http://dx.doi.org/10.1097/MAO.0000000000002253
work_keys_str_mv AT gammutea optimumcouplingofanactivemiddleearactuatoreffectofloadingforcesonactuatoroutputandconductivelosses
AT grossohmichenmartin optimumcouplingofanactivemiddleearactuatoreffectofloadingforcesonactuatoroutputandconductivelosses
AT salcherrolfb optimumcouplingofanactivemiddleearactuatoreffectofloadingforcesonactuatoroutputandconductivelosses
AT prenzlernilsk optimumcouplingofanactivemiddleearactuatoreffectofloadingforcesonactuatoroutputandconductivelosses
AT lenarzthomas optimumcouplingofanactivemiddleearactuatoreffectofloadingforcesonactuatoroutputandconductivelosses
AT maierhannes optimumcouplingofanactivemiddleearactuatoreffectofloadingforcesonactuatoroutputandconductivelosses