Autologous Transplantation of Press‐fit Bone Cylinders in the Treatment of Pelvic Nonunion
The present study describes method for autologous bone transplantation to an area of nonunion at the pelvic ring in a way that ensures the best possible bone‐to‐bone interface (“press‐fit”) and provides optimal preconditions for the ingrowth of the bone graft. We modified a technique that has been u...