Cargando…
Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures
OBJECTIVES: To analyze the curative effect of TiRobot surgical robotic navigation and location system‐assisted percutaneous sacroiliac screw fixation and percutaneous sacroiliac screw by traditional fluoroscopy, and to summarize the safety and benefits of TiRobot. METHODS: A total of 91 patients wit...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons Australia, Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6595115/ https://www.ncbi.nlm.nih.gov/pubmed/31077570 http://dx.doi.org/10.1111/os.12461 |
_version_ | 1783430346635739136 |
---|---|
author | Long, Tao Li, Kai‐nan Gao, Jin‐hua Liu, Tian‐hu Mu, Jian‐song Wang, Xue‐jun Peng, Chao He, Zhi‐yong |
author_facet | Long, Tao Li, Kai‐nan Gao, Jin‐hua Liu, Tian‐hu Mu, Jian‐song Wang, Xue‐jun Peng, Chao He, Zhi‐yong |
author_sort | Long, Tao |
collection | PubMed |
description | OBJECTIVES: To analyze the curative effect of TiRobot surgical robotic navigation and location system‐assisted percutaneous sacroiliac screw fixation and percutaneous sacroiliac screw by traditional fluoroscopy, and to summarize the safety and benefits of TiRobot. METHODS: A total of 91 patients with pelvic posterior ring fractures from December 2015 to February 2018 were included in this study. According to the surgical methods selected by the patients, the patients were divided into a TiRobot surgical robotic navigation and location system group (TiRobot group) and a percutaneous sacroiliac screw fixation group (traditional group). Statistical indicators included the number of sacroiliac screws, the time of planning the sacroiliac screw path, fluoroscopy frequency, fluoroscopy time, operation time, length of incision, blood loss, anesthesia time, the healing process of skin incisions, and fracture healing time. Fracture reduction was evaluated according to the maximum displacement degree at the inlet and outlet view X‐ray or CT. Matta standard was used to evaluate fracture reduction. At the last follow‐up, the Majeed function system was used to evaluate the function. RESULTS: All patients were followed up for 8 to 32 months. A total of 66 sacroiliac screws were implanted in the TiRobot group. A total of 43 sacroiliac screws were implanted in the traditional group. There were statistically significant differences in terms of fluoroscopy frequency, fluoroscopy time, operation time, incision length, anesthesia time, and blood loss between the two groups; the TiRobot group was superior to the traditional group. The healing time of the TiRobot group and the traditional group was 4.61 ± 0.68 months (range, 3.5–6.3 months) and 4.56 ± 0.78 months (range, 3.4–6.2 months), respectively, and there was no statistical difference. Postoperatively, by Matta standard, the overall excellent and good rate of fracture reduction was 89.28% and 88.57%, respectively. At the last follow‐up, by Majeed function score, the overall excellent and good rate was 91.07% and 91.43%. There was no statistical difference between the two groups. CONCLUSION: Sacroiliac screw implantation assisted by TiRobot to treat the posterior pelvic ring fractures has the characteristics of less trauma, shorter operation time, and less blood loss. TiRobot has the characteristics of high safety and accuracy and has great clinical application value. |
format | Online Article Text |
id | pubmed-6595115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley & Sons Australia, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-65951152019-09-10 Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures Long, Tao Li, Kai‐nan Gao, Jin‐hua Liu, Tian‐hu Mu, Jian‐song Wang, Xue‐jun Peng, Chao He, Zhi‐yong Orthop Surg Clinical Articles OBJECTIVES: To analyze the curative effect of TiRobot surgical robotic navigation and location system‐assisted percutaneous sacroiliac screw fixation and percutaneous sacroiliac screw by traditional fluoroscopy, and to summarize the safety and benefits of TiRobot. METHODS: A total of 91 patients with pelvic posterior ring fractures from December 2015 to February 2018 were included in this study. According to the surgical methods selected by the patients, the patients were divided into a TiRobot surgical robotic navigation and location system group (TiRobot group) and a percutaneous sacroiliac screw fixation group (traditional group). Statistical indicators included the number of sacroiliac screws, the time of planning the sacroiliac screw path, fluoroscopy frequency, fluoroscopy time, operation time, length of incision, blood loss, anesthesia time, the healing process of skin incisions, and fracture healing time. Fracture reduction was evaluated according to the maximum displacement degree at the inlet and outlet view X‐ray or CT. Matta standard was used to evaluate fracture reduction. At the last follow‐up, the Majeed function system was used to evaluate the function. RESULTS: All patients were followed up for 8 to 32 months. A total of 66 sacroiliac screws were implanted in the TiRobot group. A total of 43 sacroiliac screws were implanted in the traditional group. There were statistically significant differences in terms of fluoroscopy frequency, fluoroscopy time, operation time, incision length, anesthesia time, and blood loss between the two groups; the TiRobot group was superior to the traditional group. The healing time of the TiRobot group and the traditional group was 4.61 ± 0.68 months (range, 3.5–6.3 months) and 4.56 ± 0.78 months (range, 3.4–6.2 months), respectively, and there was no statistical difference. Postoperatively, by Matta standard, the overall excellent and good rate of fracture reduction was 89.28% and 88.57%, respectively. At the last follow‐up, by Majeed function score, the overall excellent and good rate was 91.07% and 91.43%. There was no statistical difference between the two groups. CONCLUSION: Sacroiliac screw implantation assisted by TiRobot to treat the posterior pelvic ring fractures has the characteristics of less trauma, shorter operation time, and less blood loss. TiRobot has the characteristics of high safety and accuracy and has great clinical application value. John Wiley & Sons Australia, Ltd 2019-05-11 /pmc/articles/PMC6595115/ /pubmed/31077570 http://dx.doi.org/10.1111/os.12461 Text en © 2019 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Clinical Articles Long, Tao Li, Kai‐nan Gao, Jin‐hua Liu, Tian‐hu Mu, Jian‐song Wang, Xue‐jun Peng, Chao He, Zhi‐yong Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures |
title | Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures |
title_full | Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures |
title_fullStr | Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures |
title_full_unstemmed | Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures |
title_short | Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures |
title_sort | comparative study of percutaneous sacroiliac screw with or without tirobot assistance for treating pelvic posterior ring fractures |
topic | Clinical Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6595115/ https://www.ncbi.nlm.nih.gov/pubmed/31077570 http://dx.doi.org/10.1111/os.12461 |
work_keys_str_mv | AT longtao comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT likainan comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT gaojinhua comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT liutianhu comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT mujiansong comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT wangxuejun comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT pengchao comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures AT hezhiyong comparativestudyofpercutaneoussacroiliacscrewwithorwithouttirobotassistancefortreatingpelvicposteriorringfractures |