Cargando…

Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty

Objective  The present study aimed to evaluate the results of the intraoperative topical use of a human fibrin sealant free of clot-stabilizing agents in total knee arthroplasties (TKAs), looking for differences between groups regarding blood loss, transfusion requirement, length of hospital stay, p...

Descripción completa

Detalles Bibliográficos
Autores principales: Pavão, Douglas Mello, Palhares, Guilherme Mathias, Albuquerque, Rodrigo Satamini Pires e, de Sousa, Eduardo Branco, Barretto, João Maurício
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6597421/
https://www.ncbi.nlm.nih.gov/pubmed/31363288
http://dx.doi.org/10.1055/s-0039-1692447
_version_ 1783430579937607680
author Pavão, Douglas Mello
Palhares, Guilherme Mathias
Albuquerque, Rodrigo Satamini Pires e
de Sousa, Eduardo Branco
Barretto, João Maurício
author_facet Pavão, Douglas Mello
Palhares, Guilherme Mathias
Albuquerque, Rodrigo Satamini Pires e
de Sousa, Eduardo Branco
Barretto, João Maurício
author_sort Pavão, Douglas Mello
collection PubMed
description Objective  The present study aimed to evaluate the results of the intraoperative topical use of a human fibrin sealant free of clot-stabilizing agents in total knee arthroplasties (TKAs), looking for differences between groups regarding blood loss, transfusion requirement, length of hospital stay, pain perception, range of motion (ROM), and incidence of complications. Methods  We have analyzed prospectively an intervention group with 32 patients (Sealant) and a control group with 31 patients (Control) with symptomatic knee osteoarthritis who underwent TKA. Results  The results were similar between the groups regarding visible blood loss in the drain in 24 hours (Control, 276.5 mL ± 46.24 versus Sealant, 365.9 mL ± 45.73), total blood loss in 24 hours (Control, 930 mL ± 78 versus Sealant, 890 mL ± 67) and in 60 hours after surgery (Control, 1,250 mL ± 120 versus Sealant, 1,190 mL ± 96), blood transfusion requirement (which occurred only in 1 control patient), length of hospital days stay (Control, 5.61 ± 0.50 versus Sealant, 4.81 ± 0.36), postoperative pain, and ROM. Sealant use was not related to wound healing complications, to infection, or to deep venous thrombosis. Conclusion  We have concluded that the hemostatic agent composed of human fibrin was not effective in reducing bleeding volume and blood transfusion requirement, nor it interfered with hospital length of stay, pain perception, and ROM. Its use was not related to any complications.
format Online
Article
Text
id pubmed-6597421
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda
record_format MEDLINE/PubMed
spelling pubmed-65974212019-07-29 Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty Pavão, Douglas Mello Palhares, Guilherme Mathias Albuquerque, Rodrigo Satamini Pires e de Sousa, Eduardo Branco Barretto, João Maurício Rev Bras Ortop (Sao Paulo) Objective  The present study aimed to evaluate the results of the intraoperative topical use of a human fibrin sealant free of clot-stabilizing agents in total knee arthroplasties (TKAs), looking for differences between groups regarding blood loss, transfusion requirement, length of hospital stay, pain perception, range of motion (ROM), and incidence of complications. Methods  We have analyzed prospectively an intervention group with 32 patients (Sealant) and a control group with 31 patients (Control) with symptomatic knee osteoarthritis who underwent TKA. Results  The results were similar between the groups regarding visible blood loss in the drain in 24 hours (Control, 276.5 mL ± 46.24 versus Sealant, 365.9 mL ± 45.73), total blood loss in 24 hours (Control, 930 mL ± 78 versus Sealant, 890 mL ± 67) and in 60 hours after surgery (Control, 1,250 mL ± 120 versus Sealant, 1,190 mL ± 96), blood transfusion requirement (which occurred only in 1 control patient), length of hospital days stay (Control, 5.61 ± 0.50 versus Sealant, 4.81 ± 0.36), postoperative pain, and ROM. Sealant use was not related to wound healing complications, to infection, or to deep venous thrombosis. Conclusion  We have concluded that the hemostatic agent composed of human fibrin was not effective in reducing bleeding volume and blood transfusion requirement, nor it interfered with hospital length of stay, pain perception, and ROM. Its use was not related to any complications. Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda 2019-05 2019-06-27 /pmc/articles/PMC6597421/ /pubmed/31363288 http://dx.doi.org/10.1055/s-0039-1692447 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Pavão, Douglas Mello
Palhares, Guilherme Mathias
Albuquerque, Rodrigo Satamini Pires e
de Sousa, Eduardo Branco
Barretto, João Maurício
Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty
title Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty
title_full Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty
title_fullStr Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty
title_full_unstemmed Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty
title_short Prospective Study on the Impact of the Use of Human Fibrin Sealant free of Clot-Stabilizing Agents in Total Knee Arthroplasty
title_sort prospective study on the impact of the use of human fibrin sealant free of clot-stabilizing agents in total knee arthroplasty
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6597421/
https://www.ncbi.nlm.nih.gov/pubmed/31363288
http://dx.doi.org/10.1055/s-0039-1692447
work_keys_str_mv AT pavaodouglasmello prospectivestudyontheimpactoftheuseofhumanfibrinsealantfreeofclotstabilizingagentsintotalkneearthroplasty
AT palharesguilhermemathias prospectivestudyontheimpactoftheuseofhumanfibrinsealantfreeofclotstabilizingagentsintotalkneearthroplasty
AT albuquerquerodrigosataminipirese prospectivestudyontheimpactoftheuseofhumanfibrinsealantfreeofclotstabilizingagentsintotalkneearthroplasty
AT desousaeduardobranco prospectivestudyontheimpactoftheuseofhumanfibrinsealantfreeofclotstabilizingagentsintotalkneearthroplasty
AT barrettojoaomauricio prospectivestudyontheimpactoftheuseofhumanfibrinsealantfreeofclotstabilizingagentsintotalkneearthroplasty