Cargando…

Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode

Steel structures are widely used in large-span bridges, offshore platforms, mining equipment and other large-scale buildings. The damage of steel structures will cause significant safety risks in a project. Therefore, it is of great significance to identify and study damage to steel structures. In t...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Muping, Sun, Xiaodan, He, Jian, Zhan, Yangyang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6600749/
https://www.ncbi.nlm.nih.gov/pubmed/31163605
http://dx.doi.org/10.3390/ma12111800
_version_ 1783431179546918912
author Hu, Muping
Sun, Xiaodan
He, Jian
Zhan, Yangyang
author_facet Hu, Muping
Sun, Xiaodan
He, Jian
Zhan, Yangyang
author_sort Hu, Muping
collection PubMed
description Steel structures are widely used in large-span bridges, offshore platforms, mining equipment and other large-scale buildings. The damage of steel structures will cause significant safety risks in a project. Therefore, it is of great significance to identify and study damage to steel structures. In this study, the propagation of Lamb waves in a steel plate with double cracks is simulated. Using finite element analysis and experimental study, damage identification and damage imaging of double crack damage to a steel plate are performed, and the numerical simulation results are in good agreement with the experimental results. Considering the reflection and transmission of Lamb waves at the welding seam, the location and imaging of crack damage in a welded steel plate are also studied. The imaging results obtained from simulation and experiment show high level in accuracy. By comparing the amplitude of the signal in the propagation process, it is concluded that the transmission energy at the weld seam decreases.
format Online
Article
Text
id pubmed-6600749
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66007492019-07-16 Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode Hu, Muping Sun, Xiaodan He, Jian Zhan, Yangyang Materials (Basel) Article Steel structures are widely used in large-span bridges, offshore platforms, mining equipment and other large-scale buildings. The damage of steel structures will cause significant safety risks in a project. Therefore, it is of great significance to identify and study damage to steel structures. In this study, the propagation of Lamb waves in a steel plate with double cracks is simulated. Using finite element analysis and experimental study, damage identification and damage imaging of double crack damage to a steel plate are performed, and the numerical simulation results are in good agreement with the experimental results. Considering the reflection and transmission of Lamb waves at the welding seam, the location and imaging of crack damage in a welded steel plate are also studied. The imaging results obtained from simulation and experiment show high level in accuracy. By comparing the amplitude of the signal in the propagation process, it is concluded that the transmission energy at the weld seam decreases. MDPI 2019-06-03 /pmc/articles/PMC6600749/ /pubmed/31163605 http://dx.doi.org/10.3390/ma12111800 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hu, Muping
Sun, Xiaodan
He, Jian
Zhan, Yangyang
Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode
title Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode
title_full Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode
title_fullStr Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode
title_full_unstemmed Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode
title_short Double Crack Damage Identification of Welded Steel Structure Based on LAMB WAVES of S0 Mode
title_sort double crack damage identification of welded steel structure based on lamb waves of s0 mode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6600749/
https://www.ncbi.nlm.nih.gov/pubmed/31163605
http://dx.doi.org/10.3390/ma12111800
work_keys_str_mv AT humuping doublecrackdamageidentificationofweldedsteelstructurebasedonlambwavesofs0mode
AT sunxiaodan doublecrackdamageidentificationofweldedsteelstructurebasedonlambwavesofs0mode
AT hejian doublecrackdamageidentificationofweldedsteelstructurebasedonlambwavesofs0mode
AT zhanyangyang doublecrackdamageidentificationofweldedsteelstructurebasedonlambwavesofs0mode