Cargando…

Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series

BACKGROUND: Optical coherence tomography (OCT)-derived fractional flow reserve (FFR)—which may be calculated using fluid dynamics—demonstrated an excellent correlation with the wire-based FFR. However, the applicability of the OCT-derived FFR in the assessment of tandem lesions is currently unclear....

Descripción completa

Detalles Bibliográficos
Autores principales: Okuya, Yoshiyuki, Seike, Fumiyasu, Yoneda, Kohei, Takahashi, Takefumi, Kishi, Koichi, Hiasa, Yoshikazu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6601174/
https://www.ncbi.nlm.nih.gov/pubmed/31449634
http://dx.doi.org/10.1093/ehjcr/ytz087
_version_ 1783431253957017600
author Okuya, Yoshiyuki
Seike, Fumiyasu
Yoneda, Kohei
Takahashi, Takefumi
Kishi, Koichi
Hiasa, Yoshikazu
author_facet Okuya, Yoshiyuki
Seike, Fumiyasu
Yoneda, Kohei
Takahashi, Takefumi
Kishi, Koichi
Hiasa, Yoshikazu
author_sort Okuya, Yoshiyuki
collection PubMed
description BACKGROUND: Optical coherence tomography (OCT)-derived fractional flow reserve (FFR)—which may be calculated using fluid dynamics—demonstrated an excellent correlation with the wire-based FFR. However, the applicability of the OCT-derived FFR in the assessment of tandem lesions is currently unclear. CASE SUMMARY: We present two cases of tandem lesions in the mid segment of the left anterior descending (LAD) artery which could have assessed accurately by OCT-derived FFR. The first patient underwent wire-based FFR at the far distal site of LAD, showed a value of 0.66. The OCT-derived FFR was calculated, yielding a value of 0.64. In the absence of stenosis at the proximal lesion, the OCT-derived FFR was calculated as 0.79, which was as same as the wire-based FFR obtained after stenting to the proximal lesion. Thus, additional stenting was performed at the distal lesion. The second patient underwent wire-based FFR at the far distal site of LAD, showed a value of 0.76 which was as same vale as OCT-derived FFR. Considering the absence of stenosis in the proximal lesion, the OCT-derived FFR was estimated as 0.88. After coronary stenting in the proximal lesion, the wire-based FFR yielded a value of 0.90. Therefore, additional intervention to the distal lesion was deferred. DISCUSSION: The described reports are the first two cases which performed physiological assessment using OCT in tandem lesions. The OCT-derived FFR might be able to estimate the wire-based FFR and the severity of each individual lesion in patients with tandem lesions.
format Online
Article
Text
id pubmed-6601174
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-66011742019-07-29 Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series Okuya, Yoshiyuki Seike, Fumiyasu Yoneda, Kohei Takahashi, Takefumi Kishi, Koichi Hiasa, Yoshikazu Eur Heart J Case Rep Case Series BACKGROUND: Optical coherence tomography (OCT)-derived fractional flow reserve (FFR)—which may be calculated using fluid dynamics—demonstrated an excellent correlation with the wire-based FFR. However, the applicability of the OCT-derived FFR in the assessment of tandem lesions is currently unclear. CASE SUMMARY: We present two cases of tandem lesions in the mid segment of the left anterior descending (LAD) artery which could have assessed accurately by OCT-derived FFR. The first patient underwent wire-based FFR at the far distal site of LAD, showed a value of 0.66. The OCT-derived FFR was calculated, yielding a value of 0.64. In the absence of stenosis at the proximal lesion, the OCT-derived FFR was calculated as 0.79, which was as same as the wire-based FFR obtained after stenting to the proximal lesion. Thus, additional stenting was performed at the distal lesion. The second patient underwent wire-based FFR at the far distal site of LAD, showed a value of 0.76 which was as same vale as OCT-derived FFR. Considering the absence of stenosis in the proximal lesion, the OCT-derived FFR was estimated as 0.88. After coronary stenting in the proximal lesion, the wire-based FFR yielded a value of 0.90. Therefore, additional intervention to the distal lesion was deferred. DISCUSSION: The described reports are the first two cases which performed physiological assessment using OCT in tandem lesions. The OCT-derived FFR might be able to estimate the wire-based FFR and the severity of each individual lesion in patients with tandem lesions. Oxford University Press 2019-05-24 /pmc/articles/PMC6601174/ /pubmed/31449634 http://dx.doi.org/10.1093/ehjcr/ytz087 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Series
Okuya, Yoshiyuki
Seike, Fumiyasu
Yoneda, Kohei
Takahashi, Takefumi
Kishi, Koichi
Hiasa, Yoshikazu
Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
title Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
title_full Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
title_fullStr Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
title_full_unstemmed Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
title_short Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
title_sort functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series
topic Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6601174/
https://www.ncbi.nlm.nih.gov/pubmed/31449634
http://dx.doi.org/10.1093/ehjcr/ytz087
work_keys_str_mv AT okuyayoshiyuki functionalassessmentoftandemcoronaryarterystenosisbyintracoronaryopticalcoherencetomographyderivedvirtualfractionalflowreserveacaseseries
AT seikefumiyasu functionalassessmentoftandemcoronaryarterystenosisbyintracoronaryopticalcoherencetomographyderivedvirtualfractionalflowreserveacaseseries
AT yonedakohei functionalassessmentoftandemcoronaryarterystenosisbyintracoronaryopticalcoherencetomographyderivedvirtualfractionalflowreserveacaseseries
AT takahashitakefumi functionalassessmentoftandemcoronaryarterystenosisbyintracoronaryopticalcoherencetomographyderivedvirtualfractionalflowreserveacaseseries
AT kishikoichi functionalassessmentoftandemcoronaryarterystenosisbyintracoronaryopticalcoherencetomographyderivedvirtualfractionalflowreserveacaseseries
AT hiasayoshikazu functionalassessmentoftandemcoronaryarterystenosisbyintracoronaryopticalcoherencetomographyderivedvirtualfractionalflowreserveacaseseries