Cargando…

Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder

AIM: To evaluate the role of baseline 12‑lead ECG in predicting the syncope mechanism during continuous monitoring using an implantable loop recorder (ILR). METHODS: Consecutive patients with syncope implanted with an ILR were enrolled. Baseline 12‑lead ECG were related to ECG diagnosis derived from...

Descripción completa

Detalles Bibliográficos
Autores principales: Sandgren, Emma, Rorsman, Cecilia, Edvardsson, Nils, Engdahl, Johan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6603332/
https://www.ncbi.nlm.nih.gov/pubmed/31304233
http://dx.doi.org/10.1016/j.ijcha.2019.100386
_version_ 1783431499714920448
author Sandgren, Emma
Rorsman, Cecilia
Edvardsson, Nils
Engdahl, Johan
author_facet Sandgren, Emma
Rorsman, Cecilia
Edvardsson, Nils
Engdahl, Johan
author_sort Sandgren, Emma
collection PubMed
description AIM: To evaluate the role of baseline 12‑lead ECG in predicting the syncope mechanism during continuous monitoring using an implantable loop recorder (ILR). METHODS: Consecutive patients with syncope implanted with an ILR were enrolled. Baseline 12‑lead ECG were related to ECG diagnosis derived from ILR tracings recorded at the time of syncope recurrence. RESULTS: In total 300 patients with a mean age of 66 ± 16 years were included, 49% (146/300) received an ILR-guided diagnosis during follow-up. Patients with abnormal baseline ECG more frequently received an ILR-guided diagnosis compared to those with normal baseline ECG 59% vs. 44%, p = 0.018. For a diagnosis of arrhythmic syncope, the corresponding frequencies were 45% vs. 26%, p = 0.001. Patients with bifascicular block significantly more common received an ILR-guided diagnosis 76% (25/33) compared to those with normal baseline ECG 44% (90/205), p ≪ 0.001. In this subgroup, 96% (24/25) were diagnosed with arrhythmic syncope, 23 of which were due to bradyarrhythmia. Bifascicular block occurred almost exclusively among those ≥60 years (31/33). After logistic regression the adjusted OR for arrhythmic syncope was significant for bifascicular block 5.5 (95%CI 2.3–13.2), p ≪ 0.001. PPV for bifascicular block in predicting arrhythmic syncope was 73% and NPV 73%. CONCLUSION: A baseline 12‑lead ECG with bifascicular block was a strong predictor for syncope during follow-up, most often due to bradyarrhythmia caused by intermittent complete heart block. No other ECG findings were associated with the ILR outcome. We find it reasonable to consider permanent pacing instead of an ILR for patients with bifascicular block and unexplained syncope.
format Online
Article
Text
id pubmed-6603332
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-66033322019-07-12 Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder Sandgren, Emma Rorsman, Cecilia Edvardsson, Nils Engdahl, Johan Int J Cardiol Heart Vasc Original Paper AIM: To evaluate the role of baseline 12‑lead ECG in predicting the syncope mechanism during continuous monitoring using an implantable loop recorder (ILR). METHODS: Consecutive patients with syncope implanted with an ILR were enrolled. Baseline 12‑lead ECG were related to ECG diagnosis derived from ILR tracings recorded at the time of syncope recurrence. RESULTS: In total 300 patients with a mean age of 66 ± 16 years were included, 49% (146/300) received an ILR-guided diagnosis during follow-up. Patients with abnormal baseline ECG more frequently received an ILR-guided diagnosis compared to those with normal baseline ECG 59% vs. 44%, p = 0.018. For a diagnosis of arrhythmic syncope, the corresponding frequencies were 45% vs. 26%, p = 0.001. Patients with bifascicular block significantly more common received an ILR-guided diagnosis 76% (25/33) compared to those with normal baseline ECG 44% (90/205), p ≪ 0.001. In this subgroup, 96% (24/25) were diagnosed with arrhythmic syncope, 23 of which were due to bradyarrhythmia. Bifascicular block occurred almost exclusively among those ≥60 years (31/33). After logistic regression the adjusted OR for arrhythmic syncope was significant for bifascicular block 5.5 (95%CI 2.3–13.2), p ≪ 0.001. PPV for bifascicular block in predicting arrhythmic syncope was 73% and NPV 73%. CONCLUSION: A baseline 12‑lead ECG with bifascicular block was a strong predictor for syncope during follow-up, most often due to bradyarrhythmia caused by intermittent complete heart block. No other ECG findings were associated with the ILR outcome. We find it reasonable to consider permanent pacing instead of an ILR for patients with bifascicular block and unexplained syncope. Elsevier 2019-06-27 /pmc/articles/PMC6603332/ /pubmed/31304233 http://dx.doi.org/10.1016/j.ijcha.2019.100386 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Paper
Sandgren, Emma
Rorsman, Cecilia
Edvardsson, Nils
Engdahl, Johan
Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
title Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
title_full Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
title_fullStr Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
title_full_unstemmed Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
title_short Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
title_sort role of baseline 12‑lead ecg in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6603332/
https://www.ncbi.nlm.nih.gov/pubmed/31304233
http://dx.doi.org/10.1016/j.ijcha.2019.100386
work_keys_str_mv AT sandgrenemma roleofbaseline12leadecginpredictingsyncopecausedbyarrhythmiainpatientsinvestigatedusinganimplantablelooprecorder
AT rorsmancecilia roleofbaseline12leadecginpredictingsyncopecausedbyarrhythmiainpatientsinvestigatedusinganimplantablelooprecorder
AT edvardssonnils roleofbaseline12leadecginpredictingsyncopecausedbyarrhythmiainpatientsinvestigatedusinganimplantablelooprecorder
AT engdahljohan roleofbaseline12leadecginpredictingsyncopecausedbyarrhythmiainpatientsinvestigatedusinganimplantablelooprecorder