Cargando…
Low-Computational Cost Stitching Method in a Three-Eyed Endoscope
Aortic valve replacement is the only definitive treatment for aortic stenosis, a highly prevalent condition in elderly population. Minimally invasive surgery brought numerous benefits to this intervention, and robotics recently provided additional improvements in terms of telemanipulation, motion sc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6604418/ https://www.ncbi.nlm.nih.gov/pubmed/31316742 http://dx.doi.org/10.1155/2019/5613931 |
_version_ | 1783431708531490816 |
---|---|
author | Mamone, Virginia Condino, Sara Cutolo, Fabrizio Tamadon, Izadyar Menciassi, Arianna Murzi, Michele Ferrari, Mauro Ferrari, Vincenzo |
author_facet | Mamone, Virginia Condino, Sara Cutolo, Fabrizio Tamadon, Izadyar Menciassi, Arianna Murzi, Michele Ferrari, Mauro Ferrari, Vincenzo |
author_sort | Mamone, Virginia |
collection | PubMed |
description | Aortic valve replacement is the only definitive treatment for aortic stenosis, a highly prevalent condition in elderly population. Minimally invasive surgery brought numerous benefits to this intervention, and robotics recently provided additional improvements in terms of telemanipulation, motion scaling, and smaller incisions. Difficulties in obtaining a clear and wide field of vision is a major challenge in minimally invasive aortic valve surgery: surgeon orientates with difficulty because of lack of direct view and limited spaces. This work focuses on the development of a computer vision methodology, for a three-eyed endoscopic vision system, to ease minimally invasive instrument guidance during aortic valve surgery. Specifically, it presents an efficient image stitching method to improve spatial awareness and overcome the orientation problems which arise when cameras are decentralized with respect to the main axis of the aorta and are nonparallel oriented. The proposed approach was tested for the navigation of an innovative robotic system for minimally invasive valve surgery. Based on the specific geometry of the setup and the intrinsic parameters of the three cameras, we estimate the proper plane-induced homographic transformation that merges the views of the operatory site plane into a single stitched image. To evaluate the deviation from the image correct alignment, we performed quantitative tests by stitching a chessboard pattern. The tests showed a minimum error with respect to the image size of 0.46 ± 0.15% measured at the homography distance of 40 mm and a maximum error of 6.09 ± 0.23% at the maximum offset of 10 mm. Three experienced surgeons in aortic valve replacement by mini-sternotomy and mini-thoracotomy performed experimental tests based on the comparison of navigation and orientation capabilities in a silicone aorta with and without stitched image. The tests showed that the stitched image allows for good orientation and navigation within the aorta, and furthermore, it provides more safety while releasing the valve than driving from the three separate views. The average processing time for the stitching of three views into one image is 12.6 ms, proving that the method is not computationally expensive, thus leaving space for further real-time processing. |
format | Online Article Text |
id | pubmed-6604418 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-66044182019-07-17 Low-Computational Cost Stitching Method in a Three-Eyed Endoscope Mamone, Virginia Condino, Sara Cutolo, Fabrizio Tamadon, Izadyar Menciassi, Arianna Murzi, Michele Ferrari, Mauro Ferrari, Vincenzo J Healthc Eng Research Article Aortic valve replacement is the only definitive treatment for aortic stenosis, a highly prevalent condition in elderly population. Minimally invasive surgery brought numerous benefits to this intervention, and robotics recently provided additional improvements in terms of telemanipulation, motion scaling, and smaller incisions. Difficulties in obtaining a clear and wide field of vision is a major challenge in minimally invasive aortic valve surgery: surgeon orientates with difficulty because of lack of direct view and limited spaces. This work focuses on the development of a computer vision methodology, for a three-eyed endoscopic vision system, to ease minimally invasive instrument guidance during aortic valve surgery. Specifically, it presents an efficient image stitching method to improve spatial awareness and overcome the orientation problems which arise when cameras are decentralized with respect to the main axis of the aorta and are nonparallel oriented. The proposed approach was tested for the navigation of an innovative robotic system for minimally invasive valve surgery. Based on the specific geometry of the setup and the intrinsic parameters of the three cameras, we estimate the proper plane-induced homographic transformation that merges the views of the operatory site plane into a single stitched image. To evaluate the deviation from the image correct alignment, we performed quantitative tests by stitching a chessboard pattern. The tests showed a minimum error with respect to the image size of 0.46 ± 0.15% measured at the homography distance of 40 mm and a maximum error of 6.09 ± 0.23% at the maximum offset of 10 mm. Three experienced surgeons in aortic valve replacement by mini-sternotomy and mini-thoracotomy performed experimental tests based on the comparison of navigation and orientation capabilities in a silicone aorta with and without stitched image. The tests showed that the stitched image allows for good orientation and navigation within the aorta, and furthermore, it provides more safety while releasing the valve than driving from the three separate views. The average processing time for the stitching of three views into one image is 12.6 ms, proving that the method is not computationally expensive, thus leaving space for further real-time processing. Hindawi 2019-06-17 /pmc/articles/PMC6604418/ /pubmed/31316742 http://dx.doi.org/10.1155/2019/5613931 Text en Copyright © 2019 Virginia Mamone et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mamone, Virginia Condino, Sara Cutolo, Fabrizio Tamadon, Izadyar Menciassi, Arianna Murzi, Michele Ferrari, Mauro Ferrari, Vincenzo Low-Computational Cost Stitching Method in a Three-Eyed Endoscope |
title | Low-Computational Cost Stitching Method in a Three-Eyed Endoscope |
title_full | Low-Computational Cost Stitching Method in a Three-Eyed Endoscope |
title_fullStr | Low-Computational Cost Stitching Method in a Three-Eyed Endoscope |
title_full_unstemmed | Low-Computational Cost Stitching Method in a Three-Eyed Endoscope |
title_short | Low-Computational Cost Stitching Method in a Three-Eyed Endoscope |
title_sort | low-computational cost stitching method in a three-eyed endoscope |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6604418/ https://www.ncbi.nlm.nih.gov/pubmed/31316742 http://dx.doi.org/10.1155/2019/5613931 |
work_keys_str_mv | AT mamonevirginia lowcomputationalcoststitchingmethodinathreeeyedendoscope AT condinosara lowcomputationalcoststitchingmethodinathreeeyedendoscope AT cutolofabrizio lowcomputationalcoststitchingmethodinathreeeyedendoscope AT tamadonizadyar lowcomputationalcoststitchingmethodinathreeeyedendoscope AT menciassiarianna lowcomputationalcoststitchingmethodinathreeeyedendoscope AT murzimichele lowcomputationalcoststitchingmethodinathreeeyedendoscope AT ferrarimauro lowcomputationalcoststitchingmethodinathreeeyedendoscope AT ferrarivincenzo lowcomputationalcoststitchingmethodinathreeeyedendoscope |