Cargando…

Magnetic particle imaging in vascular medicine

Magnetic particle imaging (MPI) is a new medical imaging technique that enables three-dimensional real-time imaging of a magnetic tracer material. Although it is not yet in clinical use, it is highly promising, especially for vascular and interventional imaging. The advantages of MPI are that no ion...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakenecker, Anna C., Ahlborg, Mandy, Debbeler, Christina, Kaethner, Christian, Buzug, Thorsten M., Lüdtke-Buzug, Kerstin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6604583/
https://www.ncbi.nlm.nih.gov/pubmed/31579782
http://dx.doi.org/10.1515/iss-2018-2026
_version_ 1783431737570754560
author Bakenecker, Anna C.
Ahlborg, Mandy
Debbeler, Christina
Kaethner, Christian
Buzug, Thorsten M.
Lüdtke-Buzug, Kerstin
author_facet Bakenecker, Anna C.
Ahlborg, Mandy
Debbeler, Christina
Kaethner, Christian
Buzug, Thorsten M.
Lüdtke-Buzug, Kerstin
author_sort Bakenecker, Anna C.
collection PubMed
description Magnetic particle imaging (MPI) is a new medical imaging technique that enables three-dimensional real-time imaging of a magnetic tracer material. Although it is not yet in clinical use, it is highly promising, especially for vascular and interventional imaging. The advantages of MPI are that no ionizing radiation is necessary, its high sensitivity enables the detection of very small amounts of the tracer material, and its high temporal resolution enables real-time imaging, which makes MPI suitable as an interventional imaging technique. As MPI is a tracer-based imaging technique, functional imaging is possible by attaching specific molecules to the tracer material. In the first part of this article, the basic principle of MPI will be explained and a short overview of the principles of the generation and spatial encoding of the tracer signal will be given. After this, the used tracer materials as well as their behavior in MPI will be introduced. A subsequent presentation of selected scanner topologies will show the current state of research and the limitations researchers are facing on the way from preclinical toward human-sized scanners. Furthermore, it will be briefly shown how to reconstruct an image from the tracer materials’ signal. In the last part, a variety of possible future clinical applications will be presented with an emphasis on vascular imaging, such as the use of MPI during cardiovascular interventions by visualizing the instruments. Investigations will be discussed, which show the feasibility to quantify the degree of stenosis and diagnose strokes and traumatic brain injuries as well as cerebral or gastrointestinal bleeding with MPI. As MPI is not only suitable for vascular medicine but also offers a broad range of other possible applications, a selection of those will be briefly presented at the end of the article.
format Online
Article
Text
id pubmed-6604583
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher De Gruyter
record_format MEDLINE/PubMed
spelling pubmed-66045832019-10-02 Magnetic particle imaging in vascular medicine Bakenecker, Anna C. Ahlborg, Mandy Debbeler, Christina Kaethner, Christian Buzug, Thorsten M. Lüdtke-Buzug, Kerstin Innov Surg Sci Review Magnetic particle imaging (MPI) is a new medical imaging technique that enables three-dimensional real-time imaging of a magnetic tracer material. Although it is not yet in clinical use, it is highly promising, especially for vascular and interventional imaging. The advantages of MPI are that no ionizing radiation is necessary, its high sensitivity enables the detection of very small amounts of the tracer material, and its high temporal resolution enables real-time imaging, which makes MPI suitable as an interventional imaging technique. As MPI is a tracer-based imaging technique, functional imaging is possible by attaching specific molecules to the tracer material. In the first part of this article, the basic principle of MPI will be explained and a short overview of the principles of the generation and spatial encoding of the tracer signal will be given. After this, the used tracer materials as well as their behavior in MPI will be introduced. A subsequent presentation of selected scanner topologies will show the current state of research and the limitations researchers are facing on the way from preclinical toward human-sized scanners. Furthermore, it will be briefly shown how to reconstruct an image from the tracer materials’ signal. In the last part, a variety of possible future clinical applications will be presented with an emphasis on vascular imaging, such as the use of MPI during cardiovascular interventions by visualizing the instruments. Investigations will be discussed, which show the feasibility to quantify the degree of stenosis and diagnose strokes and traumatic brain injuries as well as cerebral or gastrointestinal bleeding with MPI. As MPI is not only suitable for vascular medicine but also offers a broad range of other possible applications, a selection of those will be briefly presented at the end of the article. De Gruyter 2018-10-09 /pmc/articles/PMC6604583/ /pubmed/31579782 http://dx.doi.org/10.1515/iss-2018-2026 Text en ©2018 Bakenecker A.C., et al., published by De Gruyter, Berlin/Boston http://creativecommons.org/licenses/by-nc-nd/4.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.
spellingShingle Review
Bakenecker, Anna C.
Ahlborg, Mandy
Debbeler, Christina
Kaethner, Christian
Buzug, Thorsten M.
Lüdtke-Buzug, Kerstin
Magnetic particle imaging in vascular medicine
title Magnetic particle imaging in vascular medicine
title_full Magnetic particle imaging in vascular medicine
title_fullStr Magnetic particle imaging in vascular medicine
title_full_unstemmed Magnetic particle imaging in vascular medicine
title_short Magnetic particle imaging in vascular medicine
title_sort magnetic particle imaging in vascular medicine
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6604583/
https://www.ncbi.nlm.nih.gov/pubmed/31579782
http://dx.doi.org/10.1515/iss-2018-2026
work_keys_str_mv AT bakeneckerannac magneticparticleimaginginvascularmedicine
AT ahlborgmandy magneticparticleimaginginvascularmedicine
AT debbelerchristina magneticparticleimaginginvascularmedicine
AT kaethnerchristian magneticparticleimaginginvascularmedicine
AT buzugthorstenm magneticparticleimaginginvascularmedicine
AT ludtkebuzugkerstin magneticparticleimaginginvascularmedicine