Cargando…

Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations

Thoraco-lumbar osteoporotic compression fractures have a higher incidence of continued collapse with development of deformity and progression to vertebra plana when untreated and even after vertebral augmentation (VA) or balloon kyphoplasty (BKP). Even when there is the restoration of height and imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacobson, Robert E, Nenov, Anastas, Duong, Hoang D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6605968/
https://www.ncbi.nlm.nih.gov/pubmed/31281755
http://dx.doi.org/10.7759/cureus.4572
_version_ 1783431843475881984
author Jacobson, Robert E
Nenov, Anastas
Duong, Hoang D
author_facet Jacobson, Robert E
Nenov, Anastas
Duong, Hoang D
author_sort Jacobson, Robert E
collection PubMed
description Thoraco-lumbar osteoporotic compression fractures have a higher incidence of continued collapse with development of deformity and progression to vertebra plana when untreated and even after vertebral augmentation (VA) or balloon kyphoplasty (BKP). Even when there is the restoration of height and improvement in angulation, multiple long-term follow-up series have repeatedly documented that over time, many patients lose the initial height correction and in a smaller group the vertebral body re-collapses leading to the development of progressive deformity with an increased risk for adjacent level fractures. At first, larger balloons and more cement were used to try and avoid these problems, but it did not reduce the risk of adjacent fractures. Several procedures were developed to place various types of intervertebral implants combined with bone cement to maintain the initial height correction. Initial studies with these implants showed a reduction in adjacent level fractures but the systems did not proceed to market. The SpineJack(R )(SJ) system (Stryker Corp, Kalamazoo, MI), consisting of bilateral expandable titanium implants supplemented with bone cement, was first used approximately 10 years ago in Europe and recently gained FDA approval in the United States. This system provides more symmetric and balanced lateral and anterior support and is effective with lesser amounts of bone cement compared to BKP. Follow-up studies have documented that there is equal or better pain control, with better long-term results based both on maintaining vertebral height restoration and deformity correction. Most importantly, statistically it clearly reduces the risk of adjacent level fractures by at least 60%. The biomechanical effects of intravertebral implants for osteoporotic fractures in regard to the risk of adjacent level fractures and preliminary experience with the use of the SJ( )is reviewed.
format Online
Article
Text
id pubmed-6605968
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-66059682019-07-05 Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations Jacobson, Robert E Nenov, Anastas Duong, Hoang D Cureus Radiology Thoraco-lumbar osteoporotic compression fractures have a higher incidence of continued collapse with development of deformity and progression to vertebra plana when untreated and even after vertebral augmentation (VA) or balloon kyphoplasty (BKP). Even when there is the restoration of height and improvement in angulation, multiple long-term follow-up series have repeatedly documented that over time, many patients lose the initial height correction and in a smaller group the vertebral body re-collapses leading to the development of progressive deformity with an increased risk for adjacent level fractures. At first, larger balloons and more cement were used to try and avoid these problems, but it did not reduce the risk of adjacent fractures. Several procedures were developed to place various types of intervertebral implants combined with bone cement to maintain the initial height correction. Initial studies with these implants showed a reduction in adjacent level fractures but the systems did not proceed to market. The SpineJack(R )(SJ) system (Stryker Corp, Kalamazoo, MI), consisting of bilateral expandable titanium implants supplemented with bone cement, was first used approximately 10 years ago in Europe and recently gained FDA approval in the United States. This system provides more symmetric and balanced lateral and anterior support and is effective with lesser amounts of bone cement compared to BKP. Follow-up studies have documented that there is equal or better pain control, with better long-term results based both on maintaining vertebral height restoration and deformity correction. Most importantly, statistically it clearly reduces the risk of adjacent level fractures by at least 60%. The biomechanical effects of intravertebral implants for osteoporotic fractures in regard to the risk of adjacent level fractures and preliminary experience with the use of the SJ( )is reviewed. Cureus 2019-04-30 /pmc/articles/PMC6605968/ /pubmed/31281755 http://dx.doi.org/10.7759/cureus.4572 Text en Copyright © 2019, Jacobson et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Radiology
Jacobson, Robert E
Nenov, Anastas
Duong, Hoang D
Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations
title Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations
title_full Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations
title_fullStr Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations
title_full_unstemmed Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations
title_short Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations
title_sort re-expansion of osteoporotic compression fractures using bilateral spinejack implants: early clinical experience and biomechanical considerations
topic Radiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6605968/
https://www.ncbi.nlm.nih.gov/pubmed/31281755
http://dx.doi.org/10.7759/cureus.4572
work_keys_str_mv AT jacobsonroberte reexpansionofosteoporoticcompressionfracturesusingbilateralspinejackimplantsearlyclinicalexperienceandbiomechanicalconsiderations
AT nenovanastas reexpansionofosteoporoticcompressionfracturesusingbilateralspinejackimplantsearlyclinicalexperienceandbiomechanicalconsiderations
AT duonghoangd reexpansionofosteoporoticcompressionfracturesusingbilateralspinejackimplantsearlyclinicalexperienceandbiomechanicalconsiderations