Cargando…

Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models

Recent efforts to ensure the reliability of computational model-based predictions in healthcare, such as the ASME V&V40 Standard, emphasize the importance of uncertainty quantification (UQ) and sensitivity analysis (SA) when evaluating computational models. UQ involves empirically determining th...

Descripción completa

Detalles Bibliográficos
Autores principales: Pathmanathan, Pras, Cordeiro, Jonathan M., Gray, Richard A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6607060/
https://www.ncbi.nlm.nih.gov/pubmed/31297060
http://dx.doi.org/10.3389/fphys.2019.00721
_version_ 1783432018900549632
author Pathmanathan, Pras
Cordeiro, Jonathan M.
Gray, Richard A.
author_facet Pathmanathan, Pras
Cordeiro, Jonathan M.
Gray, Richard A.
author_sort Pathmanathan, Pras
collection PubMed
description Recent efforts to ensure the reliability of computational model-based predictions in healthcare, such as the ASME V&V40 Standard, emphasize the importance of uncertainty quantification (UQ) and sensitivity analysis (SA) when evaluating computational models. UQ involves empirically determining the uncertainty in model inputs—typically resulting from natural variability or measurement error—and then calculating the resultant uncertainty in model outputs. SA involves calculating how uncertainty in model outputs can be apportioned to input uncertainty. Rigorous comprehensive UQ/SA provides confidence that model-based decisions are robust to underlying uncertainties. However, comprehensive UQ/SA is not currently feasible for whole heart models, due to numerous factors including model complexity and difficulty in measuring variability in the many parameters. Here, we present a significant step to developing a framework to overcome these limitations. We: (i) developed a novel action potential (AP) model of moderate complexity (six currents, seven variables, 36 parameters); (ii) prescribed input variability for all parameters (not empirically derived); (iii) used a single “hyper-parameter” to study increasing levels of parameter uncertainty; (iv) performed UQ and SA for a range of model-derived quantities with physiological relevance; and (v) present quantitative and qualitative ways to analyze different behaviors that occur under parameter uncertainty, including “model failure”. This is the first time uncertainty in every parameter (including conductances, steady-state parameters, and time constant parameters) of every ionic current in a cardiac model has been studied. This approach allowed us to demonstrate that, for this model, the simulated AP is fully robust to low levels of parameter uncertainty — to our knowledge the first time this has been shown of any cardiac model. A range of dynamics was observed at larger parameter uncertainty (e.g., oscillatory dynamics); analysis revealed that five parameters were highly influential in these dynamics. Overall, we demonstrate feasibility of performing comprehensive UQ/SA for cardiac cell models and demonstrate how to assess robustness and overcome model failure when performing cardiac UQ analyses. The approach presented here represents an important and significant step toward the development of model-based clinical tools which are demonstrably robust to all underlying uncertainties and therefore more reliable in safety-critical decision-making.
format Online
Article
Text
id pubmed-6607060
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-66070602019-07-11 Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models Pathmanathan, Pras Cordeiro, Jonathan M. Gray, Richard A. Front Physiol Physiology Recent efforts to ensure the reliability of computational model-based predictions in healthcare, such as the ASME V&V40 Standard, emphasize the importance of uncertainty quantification (UQ) and sensitivity analysis (SA) when evaluating computational models. UQ involves empirically determining the uncertainty in model inputs—typically resulting from natural variability or measurement error—and then calculating the resultant uncertainty in model outputs. SA involves calculating how uncertainty in model outputs can be apportioned to input uncertainty. Rigorous comprehensive UQ/SA provides confidence that model-based decisions are robust to underlying uncertainties. However, comprehensive UQ/SA is not currently feasible for whole heart models, due to numerous factors including model complexity and difficulty in measuring variability in the many parameters. Here, we present a significant step to developing a framework to overcome these limitations. We: (i) developed a novel action potential (AP) model of moderate complexity (six currents, seven variables, 36 parameters); (ii) prescribed input variability for all parameters (not empirically derived); (iii) used a single “hyper-parameter” to study increasing levels of parameter uncertainty; (iv) performed UQ and SA for a range of model-derived quantities with physiological relevance; and (v) present quantitative and qualitative ways to analyze different behaviors that occur under parameter uncertainty, including “model failure”. This is the first time uncertainty in every parameter (including conductances, steady-state parameters, and time constant parameters) of every ionic current in a cardiac model has been studied. This approach allowed us to demonstrate that, for this model, the simulated AP is fully robust to low levels of parameter uncertainty — to our knowledge the first time this has been shown of any cardiac model. A range of dynamics was observed at larger parameter uncertainty (e.g., oscillatory dynamics); analysis revealed that five parameters were highly influential in these dynamics. Overall, we demonstrate feasibility of performing comprehensive UQ/SA for cardiac cell models and demonstrate how to assess robustness and overcome model failure when performing cardiac UQ analyses. The approach presented here represents an important and significant step toward the development of model-based clinical tools which are demonstrably robust to all underlying uncertainties and therefore more reliable in safety-critical decision-making. Frontiers Media S.A. 2019-06-26 /pmc/articles/PMC6607060/ /pubmed/31297060 http://dx.doi.org/10.3389/fphys.2019.00721 Text en Copyright © 2019 Pathmanathan, Cordeiro and Gray. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Pathmanathan, Pras
Cordeiro, Jonathan M.
Gray, Richard A.
Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models
title Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models
title_full Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models
title_fullStr Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models
title_full_unstemmed Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models
title_short Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models
title_sort comprehensive uncertainty quantification and sensitivity analysis for cardiac action potential models
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6607060/
https://www.ncbi.nlm.nih.gov/pubmed/31297060
http://dx.doi.org/10.3389/fphys.2019.00721
work_keys_str_mv AT pathmanathanpras comprehensiveuncertaintyquantificationandsensitivityanalysisforcardiacactionpotentialmodels
AT cordeirojonathanm comprehensiveuncertaintyquantificationandsensitivityanalysisforcardiacactionpotentialmodels
AT grayricharda comprehensiveuncertaintyquantificationandsensitivityanalysisforcardiacactionpotentialmodels