Cargando…
On-chip crystallization for serial crystallography experiments and on-chip ligand-binding studies
Efficient and reliable sample delivery has remained one of the bottlenecks for serial crystallography experiments. Compared with other methods, fixed-target sample delivery offers the advantage of significantly reduced sample consumption and shorter data collection times owing to higher hit rates. H...
Autores principales: | Lieske, Julia, Cerv, Maximilian, Kreida, Stefan, Komadina, Dana, Fischer, Janine, Barthelmess, Miriam, Fischer, Pontus, Pakendorf, Tim, Yefanov, Oleksandr, Mariani, Valerio, Seine, Thomas, Ross, Breyan H., Crosas, Eva, Lorbeer, Olga, Burkhardt, Anja, Lane, Thomas J., Guenther, Sebastian, Bergtholdt, Julian, Schoen, Silvan, Törnroth-Horsefield, Susanna, Chapman, Henry N., Meents, Alke |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6608620/ https://www.ncbi.nlm.nih.gov/pubmed/31316815 http://dx.doi.org/10.1107/S2052252519007395 |
Ejemplares similares
-
Fixed-target serial femtosecond crystallography using in cellulo grown microcrystals
por: Lahey-Rudolph, J. Mia, et al.
Publicado: (2021) -
Room-temperature macromolecular crystallography using a micro-patterned silicon chip with minimal background scattering
por: Roedig, Philip, et al.
Publicado: (2016) -
1 kHz fixed-target serial crystallography using a multilayer monochromator and an integrating pixel detector
por: Tolstikova, A., et al.
Publicado: (2019) -
A micro-patterned silicon chip as sample holder for macromolecular crystallography experiments with minimal background scattering
por: Roedig, P., et al.
Publicado: (2015) -
Mix-and-diffuse serial synchrotron crystallography
por: Beyerlein, Kenneth R., et al.
Publicado: (2017)