Cargando…

Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients

Background Neurovascular changes occur during the migraine is believed to cause alteration in cerebral and retinal circulation that possible result in damage to the brain and even retina or optic nerve. Retinal nerve fiber layer (RNFL) thickness measurement can be used as an index to assess ganglion...

Descripción completa

Detalles Bibliográficos
Autores principales: Michael, Ngu Dau Bing, Hussein, Adil, ABD Halim, Sanihah, AB Hamid, Siti Azrin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609279/
https://www.ncbi.nlm.nih.gov/pubmed/31309023
http://dx.doi.org/10.7759/cureus.4599
_version_ 1783432283747778560
author Michael, Ngu Dau Bing
Hussein, Adil
ABD Halim, Sanihah
AB Hamid, Siti Azrin
author_facet Michael, Ngu Dau Bing
Hussein, Adil
ABD Halim, Sanihah
AB Hamid, Siti Azrin
author_sort Michael, Ngu Dau Bing
collection PubMed
description Background Neurovascular changes occur during the migraine is believed to cause alteration in cerebral and retinal circulation that possible result in damage to the brain and even retina or optic nerve. Retinal nerve fiber layer (RNFL) thickness measurement can be used as an index to assess ganglion cell and retinal nerve fiber damages. The aim of this study was to evaluate the optic nerve head (ONH) parameters, RNFL thickness, and ocular perfusion pressure (OPP) in migraine patients. Methods This was a cross-sectional study, conducted in Hospital Universiti Sains Malaysia, Kelantan from July 2016 to November 2018, involving patients with a confirmed diagnosis of migraine and controls. Ninety-four eyes of 47 migraine patients and 94 eyes of 47 healthy subjects were included in this study. Blood pressure and intraocular pressure were measured and OPP was calculated. ONH parameters and RNFL thickness were measured using optical coherence tomography (OCT) after pupillary dilatation. Statistical analysis was done using Statistical Package for the Social Science (SPSS Inc Version 24). Results With respect to all means values of ONH parameters, there was no statistically significant difference between migraine patients and controls. For RNFL, there were significant reductions in average and superior RNFL thickness on both eyes with adjustment of age and gender (P-value: right eye (RE) average = 0.027; RE superior = 0.034; left eye (LE) average = 0.037; LE superior = 0.031). In view of OPP, there was no significant difference between migraine patients and controls (P-value = 0.172). Weak correlations were found between the ONH parameters and RNFL thickness with OPP, respectively, in migraine patients. Conclusion This study showed no difference in ONH parameters between migraine patients and healthy subjects. There was significant thinning in average and superior RNFL for migraine patients. No difference found in OPP between both groups. ONH parameters and RNFL thickness had a weak correlation with OPP in migraine patients.
format Online
Article
Text
id pubmed-6609279
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-66092792019-07-15 Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients Michael, Ngu Dau Bing Hussein, Adil ABD Halim, Sanihah AB Hamid, Siti Azrin Cureus Neurology Background Neurovascular changes occur during the migraine is believed to cause alteration in cerebral and retinal circulation that possible result in damage to the brain and even retina or optic nerve. Retinal nerve fiber layer (RNFL) thickness measurement can be used as an index to assess ganglion cell and retinal nerve fiber damages. The aim of this study was to evaluate the optic nerve head (ONH) parameters, RNFL thickness, and ocular perfusion pressure (OPP) in migraine patients. Methods This was a cross-sectional study, conducted in Hospital Universiti Sains Malaysia, Kelantan from July 2016 to November 2018, involving patients with a confirmed diagnosis of migraine and controls. Ninety-four eyes of 47 migraine patients and 94 eyes of 47 healthy subjects were included in this study. Blood pressure and intraocular pressure were measured and OPP was calculated. ONH parameters and RNFL thickness were measured using optical coherence tomography (OCT) after pupillary dilatation. Statistical analysis was done using Statistical Package for the Social Science (SPSS Inc Version 24). Results With respect to all means values of ONH parameters, there was no statistically significant difference between migraine patients and controls. For RNFL, there were significant reductions in average and superior RNFL thickness on both eyes with adjustment of age and gender (P-value: right eye (RE) average = 0.027; RE superior = 0.034; left eye (LE) average = 0.037; LE superior = 0.031). In view of OPP, there was no significant difference between migraine patients and controls (P-value = 0.172). Weak correlations were found between the ONH parameters and RNFL thickness with OPP, respectively, in migraine patients. Conclusion This study showed no difference in ONH parameters between migraine patients and healthy subjects. There was significant thinning in average and superior RNFL for migraine patients. No difference found in OPP between both groups. ONH parameters and RNFL thickness had a weak correlation with OPP in migraine patients. Cureus 2019-05-04 /pmc/articles/PMC6609279/ /pubmed/31309023 http://dx.doi.org/10.7759/cureus.4599 Text en Copyright © 2019, Michael et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Neurology
Michael, Ngu Dau Bing
Hussein, Adil
ABD Halim, Sanihah
AB Hamid, Siti Azrin
Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients
title Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients
title_full Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients
title_fullStr Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients
title_full_unstemmed Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients
title_short Evaluation of Optic Nerve Head Parameters, Retinal Nerve Fiber Layer Thickness, and Ocular Perfusion Pressure in Migraine Patients
title_sort evaluation of optic nerve head parameters, retinal nerve fiber layer thickness, and ocular perfusion pressure in migraine patients
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609279/
https://www.ncbi.nlm.nih.gov/pubmed/31309023
http://dx.doi.org/10.7759/cureus.4599
work_keys_str_mv AT michaelngudaubing evaluationofopticnerveheadparametersretinalnervefiberlayerthicknessandocularperfusionpressureinmigrainepatients
AT husseinadil evaluationofopticnerveheadparametersretinalnervefiberlayerthicknessandocularperfusionpressureinmigrainepatients
AT abdhalimsanihah evaluationofopticnerveheadparametersretinalnervefiberlayerthicknessandocularperfusionpressureinmigrainepatients
AT abhamidsitiazrin evaluationofopticnerveheadparametersretinalnervefiberlayerthicknessandocularperfusionpressureinmigrainepatients