Cargando…

CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?

OBJECTIVE: To retrospectively investigate whether tumor size assessment on multiplanar reconstruction (MPR) CT images better reflects pathologic T-stage than evaluation on axial images and evaluate the additional value of measurement in three-dimensional (3D) space. MATERIALS AND METHODS: From 1661...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Sohee, Lee, Sang Min, Choe, Jooae, Lee, June-Goo, Do, Kyung-Hyun, Seo, Joon Beom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609428/
https://www.ncbi.nlm.nih.gov/pubmed/31270984
http://dx.doi.org/10.3348/kjr.2018.0824
_version_ 1783432317071523840
author Park, Sohee
Lee, Sang Min
Choe, Jooae
Lee, June-Goo
Lee, Sang Min
Do, Kyung-Hyun
Seo, Joon Beom
author_facet Park, Sohee
Lee, Sang Min
Choe, Jooae
Lee, June-Goo
Lee, Sang Min
Do, Kyung-Hyun
Seo, Joon Beom
author_sort Park, Sohee
collection PubMed
description OBJECTIVE: To retrospectively investigate whether tumor size assessment on multiplanar reconstruction (MPR) CT images better reflects pathologic T-stage than evaluation on axial images and evaluate the additional value of measurement in three-dimensional (3D) space. MATERIALS AND METHODS: From 1661 patients who had undergone surgical resection for primary lung cancer between June 2013 and November 2016, 210 patients (145 men; mean age, 64.4 years) were randomly selected and 30 were assigned to each pathologic T-stage. Two readers independently measured the maximal lesion diameters on MPR CT. The longest diameters on 3D were obtained using volume segmentation. T-stages determined on CT images were compared with pathologic T-stages (overall and subgroup—Group 1, T1a/b; Group 2, T1c or higher), with differences in accuracy evaluated using McNemar's test. Agreement between readers was evaluated with intraclass correlation coefficients (ICC). RESULTS: The diagnostic accuracy of MPR measurements for determining T-stage was significantly higher than that of axial measurement alone for both reader 1 (74.3% [156/210] vs. 63.8% [134/210]; p = 0.001) and reader 2 (68.1% [143/210] vs. 61.9% [130/210]; p = 0.049). In the subgroup analysis, diagnostic accuracy with MPR diameter was significantly higher than that with axial diameter in only Group 2 (p < 0.05). Inter-reader agreements for the ICCs on axial and MPR measurements were 0.98 and 0.98. The longest diameter on 3D images showed a significantly lower performance than MPR, with an accuracy of 54.8% (115/210) (p < 0.05). CONCLUSION: Size measurement on MPR CT better reflected the pathological T-stage, specifically for T1c or higher stage lung cancer. Measurements in a 3D plane showed no added value.
format Online
Article
Text
id pubmed-6609428
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-66094282019-07-11 CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements? Park, Sohee Lee, Sang Min Choe, Jooae Lee, June-Goo Lee, Sang Min Do, Kyung-Hyun Seo, Joon Beom Korean J Radiol Thoracic Imaging OBJECTIVE: To retrospectively investigate whether tumor size assessment on multiplanar reconstruction (MPR) CT images better reflects pathologic T-stage than evaluation on axial images and evaluate the additional value of measurement in three-dimensional (3D) space. MATERIALS AND METHODS: From 1661 patients who had undergone surgical resection for primary lung cancer between June 2013 and November 2016, 210 patients (145 men; mean age, 64.4 years) were randomly selected and 30 were assigned to each pathologic T-stage. Two readers independently measured the maximal lesion diameters on MPR CT. The longest diameters on 3D were obtained using volume segmentation. T-stages determined on CT images were compared with pathologic T-stages (overall and subgroup—Group 1, T1a/b; Group 2, T1c or higher), with differences in accuracy evaluated using McNemar's test. Agreement between readers was evaluated with intraclass correlation coefficients (ICC). RESULTS: The diagnostic accuracy of MPR measurements for determining T-stage was significantly higher than that of axial measurement alone for both reader 1 (74.3% [156/210] vs. 63.8% [134/210]; p = 0.001) and reader 2 (68.1% [143/210] vs. 61.9% [130/210]; p = 0.049). In the subgroup analysis, diagnostic accuracy with MPR diameter was significantly higher than that with axial diameter in only Group 2 (p < 0.05). Inter-reader agreements for the ICCs on axial and MPR measurements were 0.98 and 0.98. The longest diameter on 3D images showed a significantly lower performance than MPR, with an accuracy of 54.8% (115/210) (p < 0.05). CONCLUSION: Size measurement on MPR CT better reflected the pathological T-stage, specifically for T1c or higher stage lung cancer. Measurements in a 3D plane showed no added value. The Korean Society of Radiology 2019-07 2019-06-03 /pmc/articles/PMC6609428/ /pubmed/31270984 http://dx.doi.org/10.3348/kjr.2018.0824 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Thoracic Imaging
Park, Sohee
Lee, Sang Min
Choe, Jooae
Lee, June-Goo
Lee, Sang Min
Do, Kyung-Hyun
Seo, Joon Beom
CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?
title CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?
title_full CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?
title_fullStr CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?
title_full_unstemmed CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?
title_short CT Evaluation for Clinical Lung Cancer Staging: Do Multiplanar Measurements Better Reflect Pathologic T-Stage than Axial Measurements?
title_sort ct evaluation for clinical lung cancer staging: do multiplanar measurements better reflect pathologic t-stage than axial measurements?
topic Thoracic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609428/
https://www.ncbi.nlm.nih.gov/pubmed/31270984
http://dx.doi.org/10.3348/kjr.2018.0824
work_keys_str_mv AT parksohee ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements
AT leesangmin ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements
AT choejooae ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements
AT leejunegoo ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements
AT leesangmin ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements
AT dokyunghyun ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements
AT seojoonbeom ctevaluationforclinicallungcancerstagingdomultiplanarmeasurementsbetterreflectpathologictstagethanaxialmeasurements