Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp

OBJECTIVE: To compare the objective and subjective image quality indicators and radiation doses of computed tomography (CT) venography performed using model-based iterative reconstruction (MBIR) at 80 kVp and adaptive statistical iterative reconstruction (ASIR)-V at 70 kVp. MATERIALS AND METHODS: Ei...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Chankue, Choo, Ki Seok, Kim, Jin Hyeok, Nam, Kyung Jin, Lee, Ji Won, Kim, Jin You
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609434/
https://www.ncbi.nlm.nih.gov/pubmed/31270980
http://dx.doi.org/10.3348/kjr.2018.0897
_version_ 1783432318457741312
author Park, Chankue
Choo, Ki Seok
Kim, Jin Hyeok
Nam, Kyung Jin
Lee, Ji Won
Kim, Jin You
author_facet Park, Chankue
Choo, Ki Seok
Kim, Jin Hyeok
Nam, Kyung Jin
Lee, Ji Won
Kim, Jin You
author_sort Park, Chankue
collection PubMed
description OBJECTIVE: To compare the objective and subjective image quality indicators and radiation doses of computed tomography (CT) venography performed using model-based iterative reconstruction (MBIR) at 80 kVp and adaptive statistical iterative reconstruction (ASIR)-V at 70 kVp. MATERIALS AND METHODS: Eighty-three patients who had undergone CT venography of the lower extremities with MBIR at 80 kVp (Group A; 21 men and 20 women; mean age, 55.5 years) or ASIR-V at 70 kVp (Group B; 18 men and 24 women; mean age, 57.3 years) were enrolled. Two radiologists retrospectively evaluated the objective (vascular enhancement, image noise, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR]) and subjective (quantum mottle, delineation of contour, venous enhancement) image quality indicators at the inferior vena cava and femoral and popliteal veins. Clinical information, radiation dose, reconstruction time, and objective and subjective image quality indicators were compared between groups A and B. RESULTS: Vascular enhancement, SNR, and CNR were significantly greater in Group B than in Group A (p ≤ 0.015). Image noise was significantly lower in Group B (p ≤ 0.021), and all subjective image quality indicators, except for delineation of vein contours, were significantly better in Group B (p ≤ 0.021). Mean reconstruction time was significantly shorter in Group B than in Group A (1 min 43 s vs. 131 min 1 s; p < 0.001). Clinical information and radiation dose were not significantly different between the two groups. CONCLUSION: CT venography using ASIR-V at 70 kVp was better than MBIR at 80 kVp in terms of image quality and reconstruction time at similar radiation doses.
format Online
Article
Text
id pubmed-6609434
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-66094342019-07-11 Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp Park, Chankue Choo, Ki Seok Kim, Jin Hyeok Nam, Kyung Jin Lee, Ji Won Kim, Jin You Korean J Radiol Cardiovascular Imaging OBJECTIVE: To compare the objective and subjective image quality indicators and radiation doses of computed tomography (CT) venography performed using model-based iterative reconstruction (MBIR) at 80 kVp and adaptive statistical iterative reconstruction (ASIR)-V at 70 kVp. MATERIALS AND METHODS: Eighty-three patients who had undergone CT venography of the lower extremities with MBIR at 80 kVp (Group A; 21 men and 20 women; mean age, 55.5 years) or ASIR-V at 70 kVp (Group B; 18 men and 24 women; mean age, 57.3 years) were enrolled. Two radiologists retrospectively evaluated the objective (vascular enhancement, image noise, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR]) and subjective (quantum mottle, delineation of contour, venous enhancement) image quality indicators at the inferior vena cava and femoral and popliteal veins. Clinical information, radiation dose, reconstruction time, and objective and subjective image quality indicators were compared between groups A and B. RESULTS: Vascular enhancement, SNR, and CNR were significantly greater in Group B than in Group A (p ≤ 0.015). Image noise was significantly lower in Group B (p ≤ 0.021), and all subjective image quality indicators, except for delineation of vein contours, were significantly better in Group B (p ≤ 0.021). Mean reconstruction time was significantly shorter in Group B than in Group A (1 min 43 s vs. 131 min 1 s; p < 0.001). Clinical information and radiation dose were not significantly different between the two groups. CONCLUSION: CT venography using ASIR-V at 70 kVp was better than MBIR at 80 kVp in terms of image quality and reconstruction time at similar radiation doses. The Korean Society of Radiology 2019-07 2019-06-25 /pmc/articles/PMC6609434/ /pubmed/31270980 http://dx.doi.org/10.3348/kjr.2018.0897 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Park, Chankue
Choo, Ki Seok
Kim, Jin Hyeok
Nam, Kyung Jin
Lee, Ji Won
Kim, Jin You
Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
title Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
title_full Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
title_fullStr Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
title_full_unstemmed Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
title_short Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
title_sort image quality and radiation dose in ct venography using model-based iterative reconstruction at 80 kvp versus adaptive statistical iterative reconstruction-v at 70 kvp
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609434/
https://www.ncbi.nlm.nih.gov/pubmed/31270980
http://dx.doi.org/10.3348/kjr.2018.0897
work_keys_str_mv AT parkchankue imagequalityandradiationdoseinctvenographyusingmodelbasediterativereconstructionat80kvpversusadaptivestatisticaliterativereconstructionvat70kvp
AT chookiseok imagequalityandradiationdoseinctvenographyusingmodelbasediterativereconstructionat80kvpversusadaptivestatisticaliterativereconstructionvat70kvp
AT kimjinhyeok imagequalityandradiationdoseinctvenographyusingmodelbasediterativereconstructionat80kvpversusadaptivestatisticaliterativereconstructionvat70kvp
AT namkyungjin imagequalityandradiationdoseinctvenographyusingmodelbasediterativereconstructionat80kvpversusadaptivestatisticaliterativereconstructionvat70kvp
AT leejiwon imagequalityandradiationdoseinctvenographyusingmodelbasediterativereconstructionat80kvpversusadaptivestatisticaliterativereconstructionvat70kvp
AT kimjinyou imagequalityandradiationdoseinctvenographyusingmodelbasediterativereconstructionat80kvpversusadaptivestatisticaliterativereconstructionvat70kvp