Cargando…
(99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans
This paper presents the results of measurements of (99m)Tc activity concentrations in indoor air in a nuclear medicine department and resulting estimated (99m)Tc intake by medical personnel. (99m)Tc air activity measurements were conducted at the Nuclear Medicine Department, John Paul II Hospital, K...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609588/ https://www.ncbi.nlm.nih.gov/pubmed/30997611 http://dx.doi.org/10.1007/s00411-019-00793-2 |
_version_ | 1783432338245419008 |
---|---|
author | Brudecki, K. Borkowska, E. Gorzkiewicz, K. Kostkiewicz, M. Mróz, T. |
author_facet | Brudecki, K. Borkowska, E. Gorzkiewicz, K. Kostkiewicz, M. Mróz, T. |
author_sort | Brudecki, K. |
collection | PubMed |
description | This paper presents the results of measurements of (99m)Tc activity concentrations in indoor air in a nuclear medicine department and resulting estimated (99m)Tc intake by medical personnel. (99m)Tc air activity measurements were conducted at the Nuclear Medicine Department, John Paul II Hospital, Krakow, Poland, during ventilation–perfusion SPECT lung scans. Technetium from the air was collected by means of a mobile aerosol sampler with a Petryanov filter operating at an average flow rate of 10 dm(3) min(−1). Measured activities ranged from 99 ± 11 to 6.1 ± 0.5 kBq m(−3). The resulting daily average intake of (99m)Tc by medical staff was estimated to be 5.4 kBq, 4.4 kBq, 3.0 kBq and 2.5 kBq, respectively, for male technicians, female technicians, male nurses and female nurses. Corresponding annual effective doses were 1.6 µSv for technicians and 1 µSv for nurses. The highest equivalent dose values were determined for extrathoracic (ET) airways: 5 µSv and 10 µSv for nurses and technicians, respectively. It is concluded that estimated annual absorbed doses are over three orders of magnitude lower than the dose limit established in the Polish Atomic Law Act and in recommendations of the International Commission on Radiological Protection for medical staff. |
format | Online Article Text |
id | pubmed-6609588 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-66095882019-07-19 (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans Brudecki, K. Borkowska, E. Gorzkiewicz, K. Kostkiewicz, M. Mróz, T. Radiat Environ Biophys Short Communication This paper presents the results of measurements of (99m)Tc activity concentrations in indoor air in a nuclear medicine department and resulting estimated (99m)Tc intake by medical personnel. (99m)Tc air activity measurements were conducted at the Nuclear Medicine Department, John Paul II Hospital, Krakow, Poland, during ventilation–perfusion SPECT lung scans. Technetium from the air was collected by means of a mobile aerosol sampler with a Petryanov filter operating at an average flow rate of 10 dm(3) min(−1). Measured activities ranged from 99 ± 11 to 6.1 ± 0.5 kBq m(−3). The resulting daily average intake of (99m)Tc by medical staff was estimated to be 5.4 kBq, 4.4 kBq, 3.0 kBq and 2.5 kBq, respectively, for male technicians, female technicians, male nurses and female nurses. Corresponding annual effective doses were 1.6 µSv for technicians and 1 µSv for nurses. The highest equivalent dose values were determined for extrathoracic (ET) airways: 5 µSv and 10 µSv for nurses and technicians, respectively. It is concluded that estimated annual absorbed doses are over three orders of magnitude lower than the dose limit established in the Polish Atomic Law Act and in recommendations of the International Commission on Radiological Protection for medical staff. Springer Berlin Heidelberg 2019-04-17 2019 /pmc/articles/PMC6609588/ /pubmed/30997611 http://dx.doi.org/10.1007/s00411-019-00793-2 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Short Communication Brudecki, K. Borkowska, E. Gorzkiewicz, K. Kostkiewicz, M. Mróz, T. (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
title | (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
title_full | (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
title_fullStr | (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
title_full_unstemmed | (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
title_short | (99m)Tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
title_sort | (99m)tc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609588/ https://www.ncbi.nlm.nih.gov/pubmed/30997611 http://dx.doi.org/10.1007/s00411-019-00793-2 |
work_keys_str_mv | AT brudeckik 99mtcactivityconcentrationsinroomairandresultinginternalcontaminationofmedicalpersonnelduringventilationperfusionlungscans AT borkowskae 99mtcactivityconcentrationsinroomairandresultinginternalcontaminationofmedicalpersonnelduringventilationperfusionlungscans AT gorzkiewiczk 99mtcactivityconcentrationsinroomairandresultinginternalcontaminationofmedicalpersonnelduringventilationperfusionlungscans AT kostkiewiczm 99mtcactivityconcentrationsinroomairandresultinginternalcontaminationofmedicalpersonnelduringventilationperfusionlungscans AT mrozt 99mtcactivityconcentrationsinroomairandresultinginternalcontaminationofmedicalpersonnelduringventilationperfusionlungscans |