Cargando…

Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study

BACKGROUND: Patients undergoing complex spine surgery present with multilevel spinal involvement, advanced age, and multiple comorbidities. Surgery is associated with significant blood loss and remarkable hemodynamic changes. The present study aimed to investigate the accuracy and trending ability o...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Feng-Cheng, Lin, Jr-Rung, Liu, Fu-Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611019/
https://www.ncbi.nlm.nih.gov/pubmed/31272378
http://dx.doi.org/10.1186/s12871-019-0790-y
_version_ 1783432613624545280
author Chang, Feng-Cheng
Lin, Jr-Rung
Liu, Fu-Chao
author_facet Chang, Feng-Cheng
Lin, Jr-Rung
Liu, Fu-Chao
author_sort Chang, Feng-Cheng
collection PubMed
description BACKGROUND: Patients undergoing complex spine surgery present with multilevel spinal involvement, advanced age, and multiple comorbidities. Surgery is associated with significant blood loss and remarkable hemodynamic changes. The present study aimed to investigate the accuracy and trending ability of a non-invasive continuous method to monitor hemoglobin (SpHb) concentrations using a Radical-7™ Pulse CO-Oximeter in complex spine surgery. METHODS: Forty-nine patients who underwent complex spine surgery were enrolled in this prospective observational study. Multiple time points were established for data collection throughout the operation. Simultaneous SpHb–total hemoglobin (tHb) paired data were recorded for analyses. Linear regression analysis, Bland–Altman plot, four-quadrant plot, and Critchley polar plot were used to assess the accuracy and trending ability of the monitor. RESULTS: A total of 272 pairs of SpHb-tHb data were available and were divided into two groups based on the perfusion index (PI): PI values ≥1.0 (n = 200) and PI values < 1.0 (n = 72). The correction coefficients (r) between SpHb and tHb were 0.6946 and 0.6861 in the groups with PI values ≥1.0 and < 1.0, respectively (P < 0000.1). In the ≥1.0 group, the mean bias was − 0.21 g/dL and the percentage error (PE) was 15.85%, whereas in the < 1.0 group, the mean bias was − 0.04 g/dL and the PE was 17.42%. Four-quadrant plot revealed a concordance rate of 85.11%, whereas the Critchley polar plot showed a concordance rate of 67.21%. CONCLUSIONS: The present study demonstrates the acceptable accuracy of the Radical-7™ Pulse CO-Oximeter even with a low PI. However, the trending ability was limited and unsatisfactory.
format Online
Article
Text
id pubmed-6611019
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66110192019-07-16 Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study Chang, Feng-Cheng Lin, Jr-Rung Liu, Fu-Chao BMC Anesthesiol Research Article BACKGROUND: Patients undergoing complex spine surgery present with multilevel spinal involvement, advanced age, and multiple comorbidities. Surgery is associated with significant blood loss and remarkable hemodynamic changes. The present study aimed to investigate the accuracy and trending ability of a non-invasive continuous method to monitor hemoglobin (SpHb) concentrations using a Radical-7™ Pulse CO-Oximeter in complex spine surgery. METHODS: Forty-nine patients who underwent complex spine surgery were enrolled in this prospective observational study. Multiple time points were established for data collection throughout the operation. Simultaneous SpHb–total hemoglobin (tHb) paired data were recorded for analyses. Linear regression analysis, Bland–Altman plot, four-quadrant plot, and Critchley polar plot were used to assess the accuracy and trending ability of the monitor. RESULTS: A total of 272 pairs of SpHb-tHb data were available and were divided into two groups based on the perfusion index (PI): PI values ≥1.0 (n = 200) and PI values < 1.0 (n = 72). The correction coefficients (r) between SpHb and tHb were 0.6946 and 0.6861 in the groups with PI values ≥1.0 and < 1.0, respectively (P < 0000.1). In the ≥1.0 group, the mean bias was − 0.21 g/dL and the percentage error (PE) was 15.85%, whereas in the < 1.0 group, the mean bias was − 0.04 g/dL and the PE was 17.42%. Four-quadrant plot revealed a concordance rate of 85.11%, whereas the Critchley polar plot showed a concordance rate of 67.21%. CONCLUSIONS: The present study demonstrates the acceptable accuracy of the Radical-7™ Pulse CO-Oximeter even with a low PI. However, the trending ability was limited and unsatisfactory. BioMed Central 2019-07-04 /pmc/articles/PMC6611019/ /pubmed/31272378 http://dx.doi.org/10.1186/s12871-019-0790-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Chang, Feng-Cheng
Lin, Jr-Rung
Liu, Fu-Chao
Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
title Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
title_full Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
title_fullStr Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
title_full_unstemmed Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
title_short Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
title_sort validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611019/
https://www.ncbi.nlm.nih.gov/pubmed/31272378
http://dx.doi.org/10.1186/s12871-019-0790-y
work_keys_str_mv AT changfengcheng validityofaccuracyandtrendingabilityofnoninvasivecontinuoustotalhemoglobinmeasurementincomplexspinesurgeryaprospectivecohortstudy
AT linjrrung validityofaccuracyandtrendingabilityofnoninvasivecontinuoustotalhemoglobinmeasurementincomplexspinesurgeryaprospectivecohortstudy
AT liufuchao validityofaccuracyandtrendingabilityofnoninvasivecontinuoustotalhemoglobinmeasurementincomplexspinesurgeryaprospectivecohortstudy