Cargando…

Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism

PURPOSE: To compare clinical outcomes following implantation of two types of posterior chamber phakic intraocular lenses: Visian™ Implantable Collamer Lens with Centraflow (ICL, V4C Staar Surgical, Nidau, Switzerland) and Implantable Phakic Contact Lens (IPCL, V1, Caregroup Sight Solution, India) fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Sachdev, Gitansha Shreyas, Singh, Shivangi, Ramamurthy, Shreyas, Rajpal, Narayan, Dandapani, Ramamurthy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611309/
https://www.ncbi.nlm.nih.gov/pubmed/31238411
http://dx.doi.org/10.4103/ijo.IJO_1501_18
_version_ 1783432670441635840
author Sachdev, Gitansha Shreyas
Singh, Shivangi
Ramamurthy, Shreyas
Rajpal, Narayan
Dandapani, Ramamurthy
author_facet Sachdev, Gitansha Shreyas
Singh, Shivangi
Ramamurthy, Shreyas
Rajpal, Narayan
Dandapani, Ramamurthy
author_sort Sachdev, Gitansha Shreyas
collection PubMed
description PURPOSE: To compare clinical outcomes following implantation of two types of posterior chamber phakic intraocular lenses: Visian™ Implantable Collamer Lens with Centraflow (ICL, V4C Staar Surgical, Nidau, Switzerland) and Implantable Phakic Contact Lens (IPCL, V1, Caregroup Sight Solution, India) for the correction of myopia and myopic astigmatism. METHODS: This retrospective case series included eyes which underwent phakic intraocular lens implantation with a minimum follow-up period of 1 year. Visual outcomes including safety, efficacy, refractive predictability, and stability were compared at 1 week and at 1, 6, and 12 months’ postoperative visit. Complications and adverse events were analyzed. RESULTS: The study included 119 and 203 eyes in the IPCL and ICL groups, respectively. At 1-year postoperative visit, median corrected distance visual acuity was 0.10 (interquartile range [IQR] 0,0.10) and 0 (IQR 0,0) in the IPCL and ICL cohorts, respectively (P = 0.066). An uncorrected visual acuity of 20/32 or better was achieved in 86.5% and 88.67% of the eyes, respectively (P = 0.574). Ninety and 94% of the eyes achieved a postoperative manifest spherical equivalent within ± 0.5D (P = 0.169, χ(2) test). Three eyes (2.52%) in the IPCL group versus one eye (0.49%) in the ICL group developed visually significant cataract requiring surgical intervention (P = 0.113). No vision-threatening complications were noted in either cohort. The mean follow-up period was 94.69 ± 32.45 and 102.67 ± 61.82 weeks, respectively. CONCLUSION: Both groups demonstrated similar efficacy and safety profile. The IPCL is an effective and economically viable option for the correction of myopia.
format Online
Article
Text
id pubmed-6611309
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-66113092019-07-22 Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism Sachdev, Gitansha Shreyas Singh, Shivangi Ramamurthy, Shreyas Rajpal, Narayan Dandapani, Ramamurthy Indian J Ophthalmol Original Article PURPOSE: To compare clinical outcomes following implantation of two types of posterior chamber phakic intraocular lenses: Visian™ Implantable Collamer Lens with Centraflow (ICL, V4C Staar Surgical, Nidau, Switzerland) and Implantable Phakic Contact Lens (IPCL, V1, Caregroup Sight Solution, India) for the correction of myopia and myopic astigmatism. METHODS: This retrospective case series included eyes which underwent phakic intraocular lens implantation with a minimum follow-up period of 1 year. Visual outcomes including safety, efficacy, refractive predictability, and stability were compared at 1 week and at 1, 6, and 12 months’ postoperative visit. Complications and adverse events were analyzed. RESULTS: The study included 119 and 203 eyes in the IPCL and ICL groups, respectively. At 1-year postoperative visit, median corrected distance visual acuity was 0.10 (interquartile range [IQR] 0,0.10) and 0 (IQR 0,0) in the IPCL and ICL cohorts, respectively (P = 0.066). An uncorrected visual acuity of 20/32 or better was achieved in 86.5% and 88.67% of the eyes, respectively (P = 0.574). Ninety and 94% of the eyes achieved a postoperative manifest spherical equivalent within ± 0.5D (P = 0.169, χ(2) test). Three eyes (2.52%) in the IPCL group versus one eye (0.49%) in the ICL group developed visually significant cataract requiring surgical intervention (P = 0.113). No vision-threatening complications were noted in either cohort. The mean follow-up period was 94.69 ± 32.45 and 102.67 ± 61.82 weeks, respectively. CONCLUSION: Both groups demonstrated similar efficacy and safety profile. The IPCL is an effective and economically viable option for the correction of myopia. Wolters Kluwer - Medknow 2019-07 /pmc/articles/PMC6611309/ /pubmed/31238411 http://dx.doi.org/10.4103/ijo.IJO_1501_18 Text en Copyright: © 2019 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sachdev, Gitansha Shreyas
Singh, Shivangi
Ramamurthy, Shreyas
Rajpal, Narayan
Dandapani, Ramamurthy
Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
title Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
title_full Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
title_fullStr Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
title_full_unstemmed Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
title_short Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
title_sort comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611309/
https://www.ncbi.nlm.nih.gov/pubmed/31238411
http://dx.doi.org/10.4103/ijo.IJO_1501_18
work_keys_str_mv AT sachdevgitanshashreyas comparativeanalysisofclinicaloutcomesbetweentwotypesofposteriorchamberphakicintraocularlensesforcorrectionofmyopiaandmyopicastigmatism
AT singhshivangi comparativeanalysisofclinicaloutcomesbetweentwotypesofposteriorchamberphakicintraocularlensesforcorrectionofmyopiaandmyopicastigmatism
AT ramamurthyshreyas comparativeanalysisofclinicaloutcomesbetweentwotypesofposteriorchamberphakicintraocularlensesforcorrectionofmyopiaandmyopicastigmatism
AT rajpalnarayan comparativeanalysisofclinicaloutcomesbetweentwotypesofposteriorchamberphakicintraocularlensesforcorrectionofmyopiaandmyopicastigmatism
AT dandapaniramamurthy comparativeanalysisofclinicaloutcomesbetweentwotypesofposteriorchamberphakicintraocularlensesforcorrectionofmyopiaandmyopicastigmatism