Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging

The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sam...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kyoung-Nam, Hernandez, Daniel, Seo, Jeung-Hoon, Noh, Young, Han, Yeji, Ryu, Yeun Chul, Chung, Jun-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611621/
https://www.ncbi.nlm.nih.gov/pubmed/31276549
http://dx.doi.org/10.1371/journal.pone.0219407
_version_ 1783432730843807744
author Kim, Kyoung-Nam
Hernandez, Daniel
Seo, Jeung-Hoon
Noh, Young
Han, Yeji
Ryu, Yeun Chul
Chung, Jun-Young
author_facet Kim, Kyoung-Nam
Hernandez, Daniel
Seo, Jeung-Hoon
Noh, Young
Han, Yeji
Ryu, Yeun Chul
Chung, Jun-Young
author_sort Kim, Kyoung-Nam
collection PubMed
description The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B(1)||) distributions of four configurations of PA coils—4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils—were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B(1)|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging.
format Online
Article
Text
id pubmed-6611621
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-66116212019-07-12 Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging Kim, Kyoung-Nam Hernandez, Daniel Seo, Jeung-Hoon Noh, Young Han, Yeji Ryu, Yeun Chul Chung, Jun-Young PLoS One Research Article The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B(1)||) distributions of four configurations of PA coils—4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils—were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B(1)|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging. Public Library of Science 2019-07-05 /pmc/articles/PMC6611621/ /pubmed/31276549 http://dx.doi.org/10.1371/journal.pone.0219407 Text en © 2019 Kim et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kim, Kyoung-Nam
Hernandez, Daniel
Seo, Jeung-Hoon
Noh, Young
Han, Yeji
Ryu, Yeun Chul
Chung, Jun-Young
Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
title Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
title_full Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
title_fullStr Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
title_full_unstemmed Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
title_short Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
title_sort quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611621/
https://www.ncbi.nlm.nih.gov/pubmed/31276549
http://dx.doi.org/10.1371/journal.pone.0219407
work_keys_str_mv AT kimkyoungnam quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging
AT hernandezdaniel quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging
AT seojeunghoon quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging
AT nohyoung quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging
AT hanyeji quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging
AT ryuyeunchul quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging
AT chungjunyoung quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging