Cargando…
Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging
The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sam...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611621/ https://www.ncbi.nlm.nih.gov/pubmed/31276549 http://dx.doi.org/10.1371/journal.pone.0219407 |
_version_ | 1783432730843807744 |
---|---|
author | Kim, Kyoung-Nam Hernandez, Daniel Seo, Jeung-Hoon Noh, Young Han, Yeji Ryu, Yeun Chul Chung, Jun-Young |
author_facet | Kim, Kyoung-Nam Hernandez, Daniel Seo, Jeung-Hoon Noh, Young Han, Yeji Ryu, Yeun Chul Chung, Jun-Young |
author_sort | Kim, Kyoung-Nam |
collection | PubMed |
description | The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B(1)||) distributions of four configurations of PA coils—4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils—were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B(1)|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging. |
format | Online Article Text |
id | pubmed-6611621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-66116212019-07-12 Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging Kim, Kyoung-Nam Hernandez, Daniel Seo, Jeung-Hoon Noh, Young Han, Yeji Ryu, Yeun Chul Chung, Jun-Young PLoS One Research Article The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B(1)||) distributions of four configurations of PA coils—4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils—were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B(1)|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging. Public Library of Science 2019-07-05 /pmc/articles/PMC6611621/ /pubmed/31276549 http://dx.doi.org/10.1371/journal.pone.0219407 Text en © 2019 Kim et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kim, Kyoung-Nam Hernandez, Daniel Seo, Jeung-Hoon Noh, Young Han, Yeji Ryu, Yeun Chul Chung, Jun-Young Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
title | Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
title_full | Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
title_fullStr | Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
title_full_unstemmed | Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
title_short | Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
title_sort | quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6611621/ https://www.ncbi.nlm.nih.gov/pubmed/31276549 http://dx.doi.org/10.1371/journal.pone.0219407 |
work_keys_str_mv | AT kimkyoungnam quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging AT hernandezdaniel quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging AT seojeunghoon quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging AT nohyoung quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging AT hanyeji quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging AT ryuyeunchul quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging AT chungjunyoung quantitativeassessmentofphasedarraycoilswithdifferentnumbersofreceivingchannelsintermsofsignaltonoiseratioandspatialnoisevariationinmagneticresonanceimaging |