Cargando…

Validation and reliability of a prototype orthodontic bracket debonding device equipped with force-sensitive resistor (FSR): a novel method of measuring orthodontic bracket debonding force in vivo

BACKGROUND: To introduce an orthodontic bracket debonding device capable of measuring debonding force clinically by a novel sensor mechanism MATERIALS AND METHOD: A prototype orthodontic debonding device was constructed utilizing a lift-off debonding instrument (LODI) and force-sensitive resistor (F...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahmed, Tamzid, Rahman, Norma Ab, Alam, Mohammad Khursheed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6612523/
https://www.ncbi.nlm.nih.gov/pubmed/31281954
http://dx.doi.org/10.1186/s40510-019-0277-x
Descripción
Sumario:BACKGROUND: To introduce an orthodontic bracket debonding device capable of measuring debonding force clinically by a novel sensor mechanism MATERIALS AND METHOD: A prototype orthodontic debonding device was constructed utilizing a lift-off debonding instrument (LODI) and force-sensitive resistor (FSR). For data interpretation, the force sensor was equipped with a microcontroller and C++ programming software running on a computer. Ninety-nine (99) 0.022-in. conventional metallic brackets were bonded to premolar teeth in vitro by a single clinician applying the same adhesive and bonding technique. For validation, the mean debonding force measured by the prototype debonding device (n = 30) and the universal testing machine (n = 30) was compared. Both intra- and inter-examiner reliability tests were done by holding and operating the device in a standardized manner. Following debonding by the prototype device, the bracket failure pattern was evaluated (n = 30) by adhesive remnant index (ARI) under the stereomicroscope at × 30 magnification. Statistical analysis included independent samples t test for validation and intraclass correlation coefficient (ICC) with a 95% confidence interval for both intra- and inter-examiner reliability. RESULTS: Mean orthodontic bracket debonding force measured by the prototype device (9.36 ± 1.65 N) and the universal testing machine (10.43 ± 2.71 N) was not significantly different (p < 0.05). The prototype device exhibited excellent intra- [ICC (3, 1) = 0.942] and inter-examiner reliability [ICC (2, 1) = 0.921] and was able to debond brackets mostly at the bracket-adhesive interface. LIMITATION: Due to adjusting the position and mechanism of the force sensor, the device had to be held in a modified standardized position. CONCLUSION: A novel method of measuring in vivo orthodontic bracket debonding force has been introduced which proved to be validated, reliable, and safe in terms of enamel damage.