Cargando…

Cerebrospinal fluid T1 value phantom reproduction at scan room temperature

The T1 value of pure water, which is often used as a phantom to simulate cerebrospinal fluid, is significantly different from that of in‐vivo cerebrospinal fluid. The purpose of this study was to develop a phantom with a T1 value equivalent to that of in‐vivo cerebrospinal fluid under examination ro...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamashiro, Akihiro, Kobayashi, Masato, Saito, Takaaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6612700/
https://www.ncbi.nlm.nih.gov/pubmed/31179645
http://dx.doi.org/10.1002/acm2.12659
_version_ 1783432919292837888
author Yamashiro, Akihiro
Kobayashi, Masato
Saito, Takaaki
author_facet Yamashiro, Akihiro
Kobayashi, Masato
Saito, Takaaki
author_sort Yamashiro, Akihiro
collection PubMed
description The T1 value of pure water, which is often used as a phantom to simulate cerebrospinal fluid, is significantly different from that of in‐vivo cerebrospinal fluid. The purpose of this study was to develop a phantom with a T1 value equivalent to that of in‐vivo cerebrospinal fluid under examination room temperature (23°C–25°C). In this study, 1.5 and 3.0 T magnetic resonance imaging scanners were used. We examined the signal intensity change in relation to pure water temperature, the T1 values of acetone‐diluted solutions (0–100 v/v%, in 10 steps), and the correlation coefficients obtained from volunteers and the prepared phantoms. The T1 value was close to the value reported in the literature for cerebrospinal fluid when the acetone‐diluted solution was 70 v/v% or higher at scan room temperature. The value at that time was 3532.81–4704.57 ms at 1.5 T and it ranged from 4052.41 to 5701.61 ms at 3.0 T. The highest correlation with the values obtained from the volunteers was r = 0.993 with pure acetone at 1.5 T and r = 0.991 with acetone 90 v/v% at 3.0 T. The relative error of the best phantom‐volunteer match was 32.61 (%) ± 6.71 at 1.5 T and 46.67 (%) ± 4.31 at 3.0 T. The T1 value measured by the null point method did not detect a significant difference between in vivo CSF and acetone 100 v/v% at 1.5 T and acetone 90 v/v% at 3.0 T. The T1 value of cerebrospinal fluid in the living body at scan room temperature was reproduced with acetone. The optimum concentration of acetone for cerebrospinal‐fluid reproduction was pure acetone at 1.5 T and 90 v/v% at 3.0 T.
format Online
Article
Text
id pubmed-6612700
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-66127002019-07-16 Cerebrospinal fluid T1 value phantom reproduction at scan room temperature Yamashiro, Akihiro Kobayashi, Masato Saito, Takaaki J Appl Clin Med Phys Medical Imaging The T1 value of pure water, which is often used as a phantom to simulate cerebrospinal fluid, is significantly different from that of in‐vivo cerebrospinal fluid. The purpose of this study was to develop a phantom with a T1 value equivalent to that of in‐vivo cerebrospinal fluid under examination room temperature (23°C–25°C). In this study, 1.5 and 3.0 T magnetic resonance imaging scanners were used. We examined the signal intensity change in relation to pure water temperature, the T1 values of acetone‐diluted solutions (0–100 v/v%, in 10 steps), and the correlation coefficients obtained from volunteers and the prepared phantoms. The T1 value was close to the value reported in the literature for cerebrospinal fluid when the acetone‐diluted solution was 70 v/v% or higher at scan room temperature. The value at that time was 3532.81–4704.57 ms at 1.5 T and it ranged from 4052.41 to 5701.61 ms at 3.0 T. The highest correlation with the values obtained from the volunteers was r = 0.993 with pure acetone at 1.5 T and r = 0.991 with acetone 90 v/v% at 3.0 T. The relative error of the best phantom‐volunteer match was 32.61 (%) ± 6.71 at 1.5 T and 46.67 (%) ± 4.31 at 3.0 T. The T1 value measured by the null point method did not detect a significant difference between in vivo CSF and acetone 100 v/v% at 1.5 T and acetone 90 v/v% at 3.0 T. The T1 value of cerebrospinal fluid in the living body at scan room temperature was reproduced with acetone. The optimum concentration of acetone for cerebrospinal‐fluid reproduction was pure acetone at 1.5 T and 90 v/v% at 3.0 T. John Wiley and Sons Inc. 2019-06-09 /pmc/articles/PMC6612700/ /pubmed/31179645 http://dx.doi.org/10.1002/acm2.12659 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Yamashiro, Akihiro
Kobayashi, Masato
Saito, Takaaki
Cerebrospinal fluid T1 value phantom reproduction at scan room temperature
title Cerebrospinal fluid T1 value phantom reproduction at scan room temperature
title_full Cerebrospinal fluid T1 value phantom reproduction at scan room temperature
title_fullStr Cerebrospinal fluid T1 value phantom reproduction at scan room temperature
title_full_unstemmed Cerebrospinal fluid T1 value phantom reproduction at scan room temperature
title_short Cerebrospinal fluid T1 value phantom reproduction at scan room temperature
title_sort cerebrospinal fluid t1 value phantom reproduction at scan room temperature
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6612700/
https://www.ncbi.nlm.nih.gov/pubmed/31179645
http://dx.doi.org/10.1002/acm2.12659
work_keys_str_mv AT yamashiroakihiro cerebrospinalfluidt1valuephantomreproductionatscanroomtemperature
AT kobayashimasato cerebrospinalfluidt1valuephantomreproductionatscanroomtemperature
AT saitotakaaki cerebrospinalfluidt1valuephantomreproductionatscanroomtemperature