Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy

BACKGROUND: Currently, there are many studies on the application of the 3D pseudocontinuous arterial spin-labeled (3D-pcASL) perfusion MRI technique for adult brain examinations, but few studies exist on the application of the technique for child brain examinations. PURPOSE: To explore the applicati...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Shilong, Liu, Xianfan, He, Ling, Liu, Bo, Qin, Bin, Feng, Chuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6613698/
https://www.ncbi.nlm.nih.gov/pubmed/31283776
http://dx.doi.org/10.1371/journal.pone.0219284
_version_ 1783433077964406784
author Tang, Shilong
Liu, Xianfan
He, Ling
Liu, Bo
Qin, Bin
Feng, Chuan
author_facet Tang, Shilong
Liu, Xianfan
He, Ling
Liu, Bo
Qin, Bin
Feng, Chuan
author_sort Tang, Shilong
collection PubMed
description BACKGROUND: Currently, there are many studies on the application of the 3D pseudocontinuous arterial spin-labeled (3D-pcASL) perfusion MRI technique for adult brain examinations, but few studies exist on the application of the technique for child brain examinations. PURPOSE: To explore the application of a 3D-pcASL perfusion MRI scan combined with postlabeling delay (PLD) for assessing neonatal hypoxic-ischemic encephalopathy (HIE). MATERIALS AND METHODS: Two-hundred neonates diagnosed with neonatal HIE were equally divided into five groups (40/group): 0- to <24-hour-old HIE group, 1- to <3-day-old HIE group, 3- to <7-day-old HIE group, 7- to <15-day-old HIE group and 15- to 28-day-old HIE group; 200 healthy neonates were equivalently divided. All 10 groups received a conventional and a 3D-pcASL perfusion MRI scan. For groups <3 days old, PLD values for the 3D-pcASL cerebral perfusion MRI scan were preset at 1025 ms; in all other groups, PLD values were preset at 1525 ms. CBF values for the 3D-pcASL cerebral perfusion MRI were compared between the HIE and corresponding control groups to determine the distinguishing characteristics of CBF values in HIE neonates. RESULTS: On the 3D-pcASL cerebral perfusion MRI scan, in the 1- to <3-day-old groups, HIE neonate CBF values were higher than those of controls in all brain regions (excluding the frontal lobe); in the 0- to <24-hour-old and 3- to <7-day-old groups, HIE neonate CBF values were lower than those of corresponding controls in all brain regions; in the 7- to <15-day-old and 15- to 28-day-old groups, there were no significant differences in the CBF values between groups in any brain regions. CONCLUSIONS: The 3D-pcASL perfusion MRI scan combined with a PLD can assist in the early diagnosis of neonatal HIE, as this method more comprehensively reflects the HIE pathological process.
format Online
Article
Text
id pubmed-6613698
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-66136982019-07-23 Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy Tang, Shilong Liu, Xianfan He, Ling Liu, Bo Qin, Bin Feng, Chuan PLoS One Research Article BACKGROUND: Currently, there are many studies on the application of the 3D pseudocontinuous arterial spin-labeled (3D-pcASL) perfusion MRI technique for adult brain examinations, but few studies exist on the application of the technique for child brain examinations. PURPOSE: To explore the application of a 3D-pcASL perfusion MRI scan combined with postlabeling delay (PLD) for assessing neonatal hypoxic-ischemic encephalopathy (HIE). MATERIALS AND METHODS: Two-hundred neonates diagnosed with neonatal HIE were equally divided into five groups (40/group): 0- to <24-hour-old HIE group, 1- to <3-day-old HIE group, 3- to <7-day-old HIE group, 7- to <15-day-old HIE group and 15- to 28-day-old HIE group; 200 healthy neonates were equivalently divided. All 10 groups received a conventional and a 3D-pcASL perfusion MRI scan. For groups <3 days old, PLD values for the 3D-pcASL cerebral perfusion MRI scan were preset at 1025 ms; in all other groups, PLD values were preset at 1525 ms. CBF values for the 3D-pcASL cerebral perfusion MRI were compared between the HIE and corresponding control groups to determine the distinguishing characteristics of CBF values in HIE neonates. RESULTS: On the 3D-pcASL cerebral perfusion MRI scan, in the 1- to <3-day-old groups, HIE neonate CBF values were higher than those of controls in all brain regions (excluding the frontal lobe); in the 0- to <24-hour-old and 3- to <7-day-old groups, HIE neonate CBF values were lower than those of corresponding controls in all brain regions; in the 7- to <15-day-old and 15- to 28-day-old groups, there were no significant differences in the CBF values between groups in any brain regions. CONCLUSIONS: The 3D-pcASL perfusion MRI scan combined with a PLD can assist in the early diagnosis of neonatal HIE, as this method more comprehensively reflects the HIE pathological process. Public Library of Science 2019-07-08 /pmc/articles/PMC6613698/ /pubmed/31283776 http://dx.doi.org/10.1371/journal.pone.0219284 Text en © 2019 Tang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tang, Shilong
Liu, Xianfan
He, Ling
Liu, Bo
Qin, Bin
Feng, Chuan
Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
title Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
title_full Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
title_fullStr Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
title_full_unstemmed Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
title_short Application of a 3D pseudocontinuous arterial spin-labeled perfusion MRI scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
title_sort application of a 3d pseudocontinuous arterial spin-labeled perfusion mri scan combined with a postlabeling delay value in the diagnosis of neonatal hypoxic-ischemic encephalopathy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6613698/
https://www.ncbi.nlm.nih.gov/pubmed/31283776
http://dx.doi.org/10.1371/journal.pone.0219284
work_keys_str_mv AT tangshilong applicationofa3dpseudocontinuousarterialspinlabeledperfusionmriscancombinedwithapostlabelingdelayvalueinthediagnosisofneonatalhypoxicischemicencephalopathy
AT liuxianfan applicationofa3dpseudocontinuousarterialspinlabeledperfusionmriscancombinedwithapostlabelingdelayvalueinthediagnosisofneonatalhypoxicischemicencephalopathy
AT heling applicationofa3dpseudocontinuousarterialspinlabeledperfusionmriscancombinedwithapostlabelingdelayvalueinthediagnosisofneonatalhypoxicischemicencephalopathy
AT liubo applicationofa3dpseudocontinuousarterialspinlabeledperfusionmriscancombinedwithapostlabelingdelayvalueinthediagnosisofneonatalhypoxicischemicencephalopathy
AT qinbin applicationofa3dpseudocontinuousarterialspinlabeledperfusionmriscancombinedwithapostlabelingdelayvalueinthediagnosisofneonatalhypoxicischemicencephalopathy
AT fengchuan applicationofa3dpseudocontinuousarterialspinlabeledperfusionmriscancombinedwithapostlabelingdelayvalueinthediagnosisofneonatalhypoxicischemicencephalopathy