Cargando…
Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis
Endovascular repair has become the standard of care for treatment of abdominal aortic aneurysms. The endografts and delivery systems for endovascular aneurysm repair have undergone multiple generations of technologic advancements. However, a significant remaining challenge for a satisfactory long-te...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6614708/ https://www.ncbi.nlm.nih.gov/pubmed/31334409 http://dx.doi.org/10.1016/j.jvscit.2019.03.014 |
_version_ | 1783433229791920128 |
---|---|
author | Rhee, Robert Peterson, Brian Moore, Erin Lepore, Michael Oderich, Gustavo |
author_facet | Rhee, Robert Peterson, Brian Moore, Erin Lepore, Michael Oderich, Gustavo |
author_sort | Rhee, Robert |
collection | PubMed |
description | Endovascular repair has become the standard of care for treatment of abdominal aortic aneurysms. The endografts and delivery systems for endovascular aneurysm repair have undergone multiple generations of technologic advancements. However, a significant remaining challenge for a satisfactory long-term outcome is to improve the performance of these devices in nonideal proximal sealing zones. In particular, short (<15 mm) and highly angulated (>60 degrees) necks can threaten long-term exclusion of the aneurysm even with the current generation of endografts. One of the main reasons for proximal infrarenal neck failure is the inability to accurately position the endograft precisely below both renal arteries. This is a report of the first-in-human implantations of the GORE EXCLUDER Conformable AAA Endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz), an investigational device, in anatomies with standard neck lengths and angulation. This device has been designed to provide repositionability, conformability, and, for the first time, optional angulation control. This device is commercially available in Europe. |
format | Online Article Text |
id | pubmed-6614708 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-66147082019-07-22 Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis Rhee, Robert Peterson, Brian Moore, Erin Lepore, Michael Oderich, Gustavo J Vasc Surg Cases Innov Tech Innovative technique Endovascular repair has become the standard of care for treatment of abdominal aortic aneurysms. The endografts and delivery systems for endovascular aneurysm repair have undergone multiple generations of technologic advancements. However, a significant remaining challenge for a satisfactory long-term outcome is to improve the performance of these devices in nonideal proximal sealing zones. In particular, short (<15 mm) and highly angulated (>60 degrees) necks can threaten long-term exclusion of the aneurysm even with the current generation of endografts. One of the main reasons for proximal infrarenal neck failure is the inability to accurately position the endograft precisely below both renal arteries. This is a report of the first-in-human implantations of the GORE EXCLUDER Conformable AAA Endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz), an investigational device, in anatomies with standard neck lengths and angulation. This device has been designed to provide repositionability, conformability, and, for the first time, optional angulation control. This device is commercially available in Europe. Elsevier 2019-06-29 /pmc/articles/PMC6614708/ /pubmed/31334409 http://dx.doi.org/10.1016/j.jvscit.2019.03.014 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Innovative technique Rhee, Robert Peterson, Brian Moore, Erin Lepore, Michael Oderich, Gustavo Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis |
title | Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis |
title_full | Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis |
title_fullStr | Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis |
title_full_unstemmed | Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis |
title_short | Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis |
title_sort | initial human experience with the gore excluder conformable aaa endoprosthesis |
topic | Innovative technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6614708/ https://www.ncbi.nlm.nih.gov/pubmed/31334409 http://dx.doi.org/10.1016/j.jvscit.2019.03.014 |
work_keys_str_mv | AT rheerobert initialhumanexperiencewiththegoreexcluderconformableaaaendoprosthesis AT petersonbrian initialhumanexperiencewiththegoreexcluderconformableaaaendoprosthesis AT mooreerin initialhumanexperiencewiththegoreexcluderconformableaaaendoprosthesis AT leporemichael initialhumanexperiencewiththegoreexcluderconformableaaaendoprosthesis AT oderichgustavo initialhumanexperiencewiththegoreexcluderconformableaaaendoprosthesis |