Cargando…

Clinical value of interferon-γ release assay in the diagnosis of active tuberculosis

Sensitivity and specificity of the interferon-γ release test for active tuberculosis screening were evaluated. Due to the high-test cost of imported IGRAs, QFT-GIT and T-SPOT.TB, we applied a cheaper domestic TB-IGRA which was approved in China recently. We recruited 740 patients and performed tuber...

Descripción completa

Detalles Bibliográficos
Autores principales: Ai, Lu, Feng, Pinning, Chen, Dubo, Chen, Shaoqian, Xu, Hongxu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6614736/
https://www.ncbi.nlm.nih.gov/pubmed/31363369
http://dx.doi.org/10.3892/etm.2019.7696
Descripción
Sumario:Sensitivity and specificity of the interferon-γ release test for active tuberculosis screening were evaluated. Due to the high-test cost of imported IGRAs, QFT-GIT and T-SPOT.TB, we applied a cheaper domestic TB-IGRA which was approved in China recently. We recruited 740 patients and performed tuberculosis interferon release test (IGRAs), detection of Mycobacterium tuberculosis IgG antibody (TB-IgG) and tuberculin skin test (TST). The sensitivity of the three methods are 90.8, 40.0 and 75.45%, with specificity of 76.62, 74.47 and 72.27%. The area under the ROC curve according to the value of T-N detected by IGRAs was 0.878 (95% CI, 0.839–0.917), with the area under the curve for the diagnosis of active pulmonary tuberculosis and extrapulmonary tuberculosis being 0.839 and 0.841 respectively. The interferon-γ release test seems to be superior to TST and TB-IgG as a screening tool for the detection of active tuberculosis in China.