Cargando…

Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position

BACKGROUND: Muscle strength measurements using hand-held dynamometry (HHD) can be affected by the inadequate strength of the tester and lack of stabilization of the participants and the device. A portable HHD anchoring system was designed that enabled the measurement of isometric knee extensor muscl...

Descripción completa

Detalles Bibliográficos
Autores principales: Sung, Kwan-Sik, Yi, You Gyoung, Shin, Hyung-Ik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6615264/
https://www.ncbi.nlm.nih.gov/pubmed/31286912
http://dx.doi.org/10.1186/s12891-019-2703-0
_version_ 1783433335120330752
author Sung, Kwan-Sik
Yi, You Gyoung
Shin, Hyung-Ik
author_facet Sung, Kwan-Sik
Yi, You Gyoung
Shin, Hyung-Ik
author_sort Sung, Kwan-Sik
collection PubMed
description BACKGROUND: Muscle strength measurements using hand-held dynamometry (HHD) can be affected by the inadequate strength of the tester and lack of stabilization of the participants and the device. A portable HHD anchoring system was designed that enabled the measurement of isometric knee extensor muscle strength in a supine position. This can be used with individuals who are unable to assume the sitting position required for the measurement of knee extensor strength in conventional isokinetic dynamometry (IKD). The aim of this study was to evaluate the reliability and validity of knee extensor strength measurements using this device. METHODS: The maximal knee extensor isometric strength of the dominant leg in healthy adults aged 20 to 40 years was tested. Three trials of three contractions were assessed by two raters using the portable dynamometer anchoring system whilst the participant was in the supine position. After the three measurement trials, peak knee extensor torque was evaluated using IKD. The intraclass correlation coefficient (ICC) and 95% limits of agreement (LOA) for intra- and inter-rater reliability were obtained. RESULTS: Thirty-nine participants (19 male and 20 female, aged 30.08 ± 4.16 y), completed the three measurement trials. The ICC for intra-rater reliability was 0.98 for the maximum measurements of knee extensor strength (95% confidence interval [CI]: 0.96–0.98) and 0.98 (95% CI: 0.96–0.99) for inter-rater reliability. The mean difference (%) between the maximum knee extensor strength measurements of each trial was 1.02% (LOA range: − 11.13 to 13.16%) for intra-rater and − 1.44% (LOA range: − 13.98 to 11.08%) for inter-rater measurements. The Pearson correlation coefficient of the maximum voluntary peak torque measurements with the portable dynamometer anchoring system and IKD was 0.927. CONCLUSIONS: The portable dynamometer anchoring system is a reliable and valid tool for measuring isometric knee extensor strength in a supine position. Future clinical feasibility studies are needed to determine if this equipment can be applied to people with severe illness or disabilities. TRIAL REGISTRATION: KCT0003041. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12891-019-2703-0) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6615264
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66152642019-07-18 Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position Sung, Kwan-Sik Yi, You Gyoung Shin, Hyung-Ik BMC Musculoskelet Disord Research Article BACKGROUND: Muscle strength measurements using hand-held dynamometry (HHD) can be affected by the inadequate strength of the tester and lack of stabilization of the participants and the device. A portable HHD anchoring system was designed that enabled the measurement of isometric knee extensor muscle strength in a supine position. This can be used with individuals who are unable to assume the sitting position required for the measurement of knee extensor strength in conventional isokinetic dynamometry (IKD). The aim of this study was to evaluate the reliability and validity of knee extensor strength measurements using this device. METHODS: The maximal knee extensor isometric strength of the dominant leg in healthy adults aged 20 to 40 years was tested. Three trials of three contractions were assessed by two raters using the portable dynamometer anchoring system whilst the participant was in the supine position. After the three measurement trials, peak knee extensor torque was evaluated using IKD. The intraclass correlation coefficient (ICC) and 95% limits of agreement (LOA) for intra- and inter-rater reliability were obtained. RESULTS: Thirty-nine participants (19 male and 20 female, aged 30.08 ± 4.16 y), completed the three measurement trials. The ICC for intra-rater reliability was 0.98 for the maximum measurements of knee extensor strength (95% confidence interval [CI]: 0.96–0.98) and 0.98 (95% CI: 0.96–0.99) for inter-rater reliability. The mean difference (%) between the maximum knee extensor strength measurements of each trial was 1.02% (LOA range: − 11.13 to 13.16%) for intra-rater and − 1.44% (LOA range: − 13.98 to 11.08%) for inter-rater measurements. The Pearson correlation coefficient of the maximum voluntary peak torque measurements with the portable dynamometer anchoring system and IKD was 0.927. CONCLUSIONS: The portable dynamometer anchoring system is a reliable and valid tool for measuring isometric knee extensor strength in a supine position. Future clinical feasibility studies are needed to determine if this equipment can be applied to people with severe illness or disabilities. TRIAL REGISTRATION: KCT0003041. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12891-019-2703-0) contains supplementary material, which is available to authorized users. BioMed Central 2019-07-08 /pmc/articles/PMC6615264/ /pubmed/31286912 http://dx.doi.org/10.1186/s12891-019-2703-0 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Sung, Kwan-Sik
Yi, You Gyoung
Shin, Hyung-Ik
Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
title Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
title_full Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
title_fullStr Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
title_full_unstemmed Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
title_short Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
title_sort reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6615264/
https://www.ncbi.nlm.nih.gov/pubmed/31286912
http://dx.doi.org/10.1186/s12891-019-2703-0
work_keys_str_mv AT sungkwansik reliabilityandvalidityofkneeextensorstrengthmeasurementsusingaportabledynamometeranchoringsysteminasupineposition
AT yiyougyoung reliabilityandvalidityofkneeextensorstrengthmeasurementsusingaportabledynamometeranchoringsysteminasupineposition
AT shinhyungik reliabilityandvalidityofkneeextensorstrengthmeasurementsusingaportabledynamometeranchoringsysteminasupineposition