Cargando…

Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study

Ultrasound-guided central venous catheterization may cause lethal mechanical complications intraoperatively. We developed a novel device to prevent such complications. It works as a needle guide to supplement the operator's skill. We evaluated the utility of this device in terms of the success...

Descripción completa

Detalles Bibliográficos
Autores principales: Asao, Takayuki, Kikuchi, Mami, Tokumine, Joho, Matsushima, Hisao, Andoh, Hideaki, Tanaka, Kazumi, Kanamoto, Masafumi, Ideno, Yuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6616625/
https://www.ncbi.nlm.nih.gov/pubmed/31261532
http://dx.doi.org/10.1097/MD.0000000000016126
_version_ 1783433547321704448
author Asao, Takayuki
Kikuchi, Mami
Tokumine, Joho
Matsushima, Hisao
Andoh, Hideaki
Tanaka, Kazumi
Kanamoto, Masafumi
Ideno, Yuki
author_facet Asao, Takayuki
Kikuchi, Mami
Tokumine, Joho
Matsushima, Hisao
Andoh, Hideaki
Tanaka, Kazumi
Kanamoto, Masafumi
Ideno, Yuki
author_sort Asao, Takayuki
collection PubMed
description Ultrasound-guided central venous catheterization may cause lethal mechanical complications intraoperatively. We developed a novel device to prevent such complications. It works as a needle guide to supplement the operator's skill. We evaluated the utility of this device in terms of the success rate and visualization of the needle tip while penetrating the target vessel using a simulator. This study was approved by the local ethics committee. The new device – an optical skill-assist device – has a slit and a mirror in the center. The operator can see the needle's reflection in the mirror through the slit and can thus ensure that the needle is directed in line with the ultrasound beam. Participants were recruited by placing an advertisement for a hands-on seminar on ultrasound-guided vascular access. They received hands-on training on the in-plane approach for 2 hours. Pre-test and post-test without the device and an additional test using the device were performed to evaluate the proficiency of ultrasound-guided vascular access. An endoscope inserted into the simulated vessel was used to detect the precise location of the needle tip in the vessel. The primary outcomes were the success rate of the procedure. The secondary outcome was visualization of the needle tip while penetrating the simulated vessel. The chi-squared test was used for comparing the success rate and needle tip visualization between the different tests. P < .05 was considered to indicate significant differences. Forty-two participants were enrolled in this study. The success rate did not increase after the simulation training (P = .1). Using the optical skill-assist device, the rate improved to 100%. There was a significant difference in success rate between the pre-test and additional test using the optical skill-assist device (P = .003). Needle tip visualization significantly improved with the use of the optical skill-assist device compared to the pre-test (P < .001) and post-test (P = .001). Simulation training improved participants’ skill for ultrasound-guided vascular access, but the improvement depended on each participant. However, further, improvement was achieved with the use of the optical skill-assist device. The optical skill-assist device is useful for supplementing the operator's skill for ultrasound-guided central venous catheterization.
format Online
Article
Text
id pubmed-6616625
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-66166252019-07-22 Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study Asao, Takayuki Kikuchi, Mami Tokumine, Joho Matsushima, Hisao Andoh, Hideaki Tanaka, Kazumi Kanamoto, Masafumi Ideno, Yuki Medicine (Baltimore) Research Article Ultrasound-guided central venous catheterization may cause lethal mechanical complications intraoperatively. We developed a novel device to prevent such complications. It works as a needle guide to supplement the operator's skill. We evaluated the utility of this device in terms of the success rate and visualization of the needle tip while penetrating the target vessel using a simulator. This study was approved by the local ethics committee. The new device – an optical skill-assist device – has a slit and a mirror in the center. The operator can see the needle's reflection in the mirror through the slit and can thus ensure that the needle is directed in line with the ultrasound beam. Participants were recruited by placing an advertisement for a hands-on seminar on ultrasound-guided vascular access. They received hands-on training on the in-plane approach for 2 hours. Pre-test and post-test without the device and an additional test using the device were performed to evaluate the proficiency of ultrasound-guided vascular access. An endoscope inserted into the simulated vessel was used to detect the precise location of the needle tip in the vessel. The primary outcomes were the success rate of the procedure. The secondary outcome was visualization of the needle tip while penetrating the simulated vessel. The chi-squared test was used for comparing the success rate and needle tip visualization between the different tests. P < .05 was considered to indicate significant differences. Forty-two participants were enrolled in this study. The success rate did not increase after the simulation training (P = .1). Using the optical skill-assist device, the rate improved to 100%. There was a significant difference in success rate between the pre-test and additional test using the optical skill-assist device (P = .003). Needle tip visualization significantly improved with the use of the optical skill-assist device compared to the pre-test (P < .001) and post-test (P = .001). Simulation training improved participants’ skill for ultrasound-guided vascular access, but the improvement depended on each participant. However, further, improvement was achieved with the use of the optical skill-assist device. The optical skill-assist device is useful for supplementing the operator's skill for ultrasound-guided central venous catheterization. Wolters Kluwer Health 2019-06-28 /pmc/articles/PMC6616625/ /pubmed/31261532 http://dx.doi.org/10.1097/MD.0000000000016126 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle Research Article
Asao, Takayuki
Kikuchi, Mami
Tokumine, Joho
Matsushima, Hisao
Andoh, Hideaki
Tanaka, Kazumi
Kanamoto, Masafumi
Ideno, Yuki
Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
title Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
title_full Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
title_fullStr Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
title_full_unstemmed Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
title_short Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
title_sort optical skill-assist device for ultrasound-guided vascular access: a preliminary simulation study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6616625/
https://www.ncbi.nlm.nih.gov/pubmed/31261532
http://dx.doi.org/10.1097/MD.0000000000016126
work_keys_str_mv AT asaotakayuki opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT kikuchimami opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT tokuminejoho opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT matsushimahisao opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT andohhideaki opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT tanakakazumi opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT kanamotomasafumi opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy
AT idenoyuki opticalskillassistdeviceforultrasoundguidedvascularaccessapreliminarysimulationstudy