Cargando…

Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value

Background: The clinical practice shows that many low-dose ACTH-stimulation tests have a false positive result. The aim of the study was to determine the diagnostic accuracy of a low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency and to define its optimal cut-off. Methods: We a...

Descripción completa

Detalles Bibliográficos
Autores principales: Mongioì, Laura Maria, Condorelli, Rosita Angela, Barbagallo, Federica, Cannarella, Rossella, La Vignera, Sandro, Calogero, Aldo Eugenio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6616948/
https://www.ncbi.nlm.nih.gov/pubmed/31195750
http://dx.doi.org/10.3390/jcm8060806
_version_ 1783433579229872128
author Mongioì, Laura Maria
Condorelli, Rosita Angela
Barbagallo, Federica
Cannarella, Rossella
La Vignera, Sandro
Calogero, Aldo Eugenio
author_facet Mongioì, Laura Maria
Condorelli, Rosita Angela
Barbagallo, Federica
Cannarella, Rossella
La Vignera, Sandro
Calogero, Aldo Eugenio
author_sort Mongioì, Laura Maria
collection PubMed
description Background: The clinical practice shows that many low-dose ACTH-stimulation tests have a false positive result. The aim of the study was to determine the diagnostic accuracy of a low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency and to define its optimal cut-off. Methods: We analyzed data from 103 patients undergoing 1 µg ACTH-stimulation test. Four patients had adrenal insufficiency (AI) upon follow up: Two primary, and two secondary AI. Cortisol serum levels were evaluated at time 0, 20’, and 30’ after the injection of 1 µg i.v. of ACTH. The sensitivity, specificity, accuracy, and positive and negative predictive values of the test were calculated for both 20’ and 30’ sampling. The receiver operating characteristic (ROC) curve was obtained to assess the sensitivity and specificity of low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency at different cut-off values. Results: Considering 500 nmol/L as the standard cut-off value, low-dose ACTH stimulation test showed a 100% sensitivity and a 67.3% specificity, with a high rate of false positive results. ROC curve analysis showed that the cut-off of 401.5 nmol/L is the best compromise between sensitivity (100%) and specificity (93.9%). Conclusions: By using a cut-off value of 401.5 nmol/L for the low-dose ACTH stimulation test, the number of false positive patients decreased significantly, but the sensitivity remained high.
format Online
Article
Text
id pubmed-6616948
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66169482019-07-18 Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value Mongioì, Laura Maria Condorelli, Rosita Angela Barbagallo, Federica Cannarella, Rossella La Vignera, Sandro Calogero, Aldo Eugenio J Clin Med Article Background: The clinical practice shows that many low-dose ACTH-stimulation tests have a false positive result. The aim of the study was to determine the diagnostic accuracy of a low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency and to define its optimal cut-off. Methods: We analyzed data from 103 patients undergoing 1 µg ACTH-stimulation test. Four patients had adrenal insufficiency (AI) upon follow up: Two primary, and two secondary AI. Cortisol serum levels were evaluated at time 0, 20’, and 30’ after the injection of 1 µg i.v. of ACTH. The sensitivity, specificity, accuracy, and positive and negative predictive values of the test were calculated for both 20’ and 30’ sampling. The receiver operating characteristic (ROC) curve was obtained to assess the sensitivity and specificity of low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency at different cut-off values. Results: Considering 500 nmol/L as the standard cut-off value, low-dose ACTH stimulation test showed a 100% sensitivity and a 67.3% specificity, with a high rate of false positive results. ROC curve analysis showed that the cut-off of 401.5 nmol/L is the best compromise between sensitivity (100%) and specificity (93.9%). Conclusions: By using a cut-off value of 401.5 nmol/L for the low-dose ACTH stimulation test, the number of false positive patients decreased significantly, but the sensitivity remained high. MDPI 2019-06-05 /pmc/articles/PMC6616948/ /pubmed/31195750 http://dx.doi.org/10.3390/jcm8060806 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mongioì, Laura Maria
Condorelli, Rosita Angela
Barbagallo, Federica
Cannarella, Rossella
La Vignera, Sandro
Calogero, Aldo Eugenio
Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value
title Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value
title_full Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value
title_fullStr Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value
title_full_unstemmed Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value
title_short Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value
title_sort accuracy of the low-dose acth stimulation test for adrenal insufficiency diagnosis: a re-assessment of the cut-off value
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6616948/
https://www.ncbi.nlm.nih.gov/pubmed/31195750
http://dx.doi.org/10.3390/jcm8060806
work_keys_str_mv AT mongioilauramaria accuracyofthelowdoseacthstimulationtestforadrenalinsufficiencydiagnosisareassessmentofthecutoffvalue
AT condorellirositaangela accuracyofthelowdoseacthstimulationtestforadrenalinsufficiencydiagnosisareassessmentofthecutoffvalue
AT barbagallofederica accuracyofthelowdoseacthstimulationtestforadrenalinsufficiencydiagnosisareassessmentofthecutoffvalue
AT cannarellarossella accuracyofthelowdoseacthstimulationtestforadrenalinsufficiencydiagnosisareassessmentofthecutoffvalue
AT lavignerasandro accuracyofthelowdoseacthstimulationtestforadrenalinsufficiencydiagnosisareassessmentofthecutoffvalue
AT calogeroaldoeugenio accuracyofthelowdoseacthstimulationtestforadrenalinsufficiencydiagnosisareassessmentofthecutoffvalue