Cargando…
Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
BACKGROUND: Endoscopic mucosal resection (EMR) in piecemeal technique is the treatment standard for larger flat or sessile colorectal lesions. The method is burdened by a high recurrence rate mostly presenting as difficult to resect lesions. In these situations, endoscopic full thickness resection (...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6617569/ https://www.ncbi.nlm.nih.gov/pubmed/31291893 http://dx.doi.org/10.1186/s12876-019-1043-8 |
_version_ | 1783433720170020864 |
---|---|
author | von Helden, Annabell Hildenbrand, Ralf Sido, Bernd Dumoulin, Franz Ludwig |
author_facet | von Helden, Annabell Hildenbrand, Ralf Sido, Bernd Dumoulin, Franz Ludwig |
author_sort | von Helden, Annabell |
collection | PubMed |
description | BACKGROUND: Endoscopic mucosal resection (EMR) in piecemeal technique is the treatment standard for larger flat or sessile colorectal lesions. The method is burdened by a high recurrence rate mostly presenting as difficult to resect lesions. In these situations, endoscopic full thickness resection (EFTR) with an over-the-scope device offers the option of complete resection despite scar formation. METHODS: We conducted a retrospective case review of 30 consecutive EFTR interventions on small (< 20 mm), difficult to resect recurrent / residual colorectal neoplastic lesions treated by EFTR. RESULTS: EFTR was technically feasible in 28/30 (93,3%) of the cases with an R0 resection in 24/30 (80%) and a median procedure time (marking to full thickness resection) of 34,5 min (11–120). After the first 15 procedures, the per-protocol rate increased from 13/15 to 15/15 and the R0 resection rate increased from 9/15 (69,2%) to 15/15 (100,0%; p < 0.01). One patient suffered from a delayed perforation the day after the procedure and needed emergency surgery (3,6%). Minor bleeding occurred in 3/28 patients (10,7%) and post-interventional fever in one patient (3,6%). The 30-day mortality rate was 0%. CONCLUSIONS: EFTR with an over-the-scope device is a useful method for endoscopic resection of difficult to treat recurrent or residual colorectal neoplasia after previous endoscopic therapy. High R0 resection rates were observed after a relatively short learning curve. The complication rate in this series seems acceptable given the complexity of the resected lesions. |
format | Online Article Text |
id | pubmed-6617569 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-66175692019-07-18 Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series von Helden, Annabell Hildenbrand, Ralf Sido, Bernd Dumoulin, Franz Ludwig BMC Gastroenterol Research Article BACKGROUND: Endoscopic mucosal resection (EMR) in piecemeal technique is the treatment standard for larger flat or sessile colorectal lesions. The method is burdened by a high recurrence rate mostly presenting as difficult to resect lesions. In these situations, endoscopic full thickness resection (EFTR) with an over-the-scope device offers the option of complete resection despite scar formation. METHODS: We conducted a retrospective case review of 30 consecutive EFTR interventions on small (< 20 mm), difficult to resect recurrent / residual colorectal neoplastic lesions treated by EFTR. RESULTS: EFTR was technically feasible in 28/30 (93,3%) of the cases with an R0 resection in 24/30 (80%) and a median procedure time (marking to full thickness resection) of 34,5 min (11–120). After the first 15 procedures, the per-protocol rate increased from 13/15 to 15/15 and the R0 resection rate increased from 9/15 (69,2%) to 15/15 (100,0%; p < 0.01). One patient suffered from a delayed perforation the day after the procedure and needed emergency surgery (3,6%). Minor bleeding occurred in 3/28 patients (10,7%) and post-interventional fever in one patient (3,6%). The 30-day mortality rate was 0%. CONCLUSIONS: EFTR with an over-the-scope device is a useful method for endoscopic resection of difficult to treat recurrent or residual colorectal neoplasia after previous endoscopic therapy. High R0 resection rates were observed after a relatively short learning curve. The complication rate in this series seems acceptable given the complexity of the resected lesions. BioMed Central 2019-07-10 /pmc/articles/PMC6617569/ /pubmed/31291893 http://dx.doi.org/10.1186/s12876-019-1043-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article von Helden, Annabell Hildenbrand, Ralf Sido, Bernd Dumoulin, Franz Ludwig Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
title | Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
title_full | Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
title_fullStr | Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
title_full_unstemmed | Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
title_short | Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
title_sort | endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6617569/ https://www.ncbi.nlm.nih.gov/pubmed/31291893 http://dx.doi.org/10.1186/s12876-019-1043-8 |
work_keys_str_mv | AT vonheldenannabell endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries AT hildenbrandralf endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries AT sidobernd endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries AT dumoulinfranzludwig endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries |