Cargando…

Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series

BACKGROUND: Endoscopic mucosal resection (EMR) in piecemeal technique is the treatment standard for larger flat or sessile colorectal lesions. The method is burdened by a high recurrence rate mostly presenting as difficult to resect lesions. In these situations, endoscopic full thickness resection (...

Descripción completa

Detalles Bibliográficos
Autores principales: von Helden, Annabell, Hildenbrand, Ralf, Sido, Bernd, Dumoulin, Franz Ludwig
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6617569/
https://www.ncbi.nlm.nih.gov/pubmed/31291893
http://dx.doi.org/10.1186/s12876-019-1043-8
_version_ 1783433720170020864
author von Helden, Annabell
Hildenbrand, Ralf
Sido, Bernd
Dumoulin, Franz Ludwig
author_facet von Helden, Annabell
Hildenbrand, Ralf
Sido, Bernd
Dumoulin, Franz Ludwig
author_sort von Helden, Annabell
collection PubMed
description BACKGROUND: Endoscopic mucosal resection (EMR) in piecemeal technique is the treatment standard for larger flat or sessile colorectal lesions. The method is burdened by a high recurrence rate mostly presenting as difficult to resect lesions. In these situations, endoscopic full thickness resection (EFTR) with an over-the-scope device offers the option of complete resection despite scar formation. METHODS: We conducted a retrospective case review of 30 consecutive EFTR interventions on small (< 20 mm), difficult to resect recurrent / residual colorectal neoplastic lesions treated by EFTR. RESULTS: EFTR was technically feasible in 28/30 (93,3%) of the cases with an R0 resection in 24/30 (80%) and a median procedure time (marking to full thickness resection) of 34,5 min (11–120). After the first 15 procedures, the per-protocol rate increased from 13/15 to 15/15 and the R0 resection rate increased from 9/15 (69,2%) to 15/15 (100,0%; p < 0.01). One patient suffered from a delayed perforation the day after the procedure and needed emergency surgery (3,6%). Minor bleeding occurred in 3/28 patients (10,7%) and post-interventional fever in one patient (3,6%). The 30-day mortality rate was 0%. CONCLUSIONS: EFTR with an over-the-scope device is a useful method for endoscopic resection of difficult to treat recurrent or residual colorectal neoplasia after previous endoscopic therapy. High R0 resection rates were observed after a relatively short learning curve. The complication rate in this series seems acceptable given the complexity of the resected lesions.
format Online
Article
Text
id pubmed-6617569
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66175692019-07-18 Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series von Helden, Annabell Hildenbrand, Ralf Sido, Bernd Dumoulin, Franz Ludwig BMC Gastroenterol Research Article BACKGROUND: Endoscopic mucosal resection (EMR) in piecemeal technique is the treatment standard for larger flat or sessile colorectal lesions. The method is burdened by a high recurrence rate mostly presenting as difficult to resect lesions. In these situations, endoscopic full thickness resection (EFTR) with an over-the-scope device offers the option of complete resection despite scar formation. METHODS: We conducted a retrospective case review of 30 consecutive EFTR interventions on small (< 20 mm), difficult to resect recurrent / residual colorectal neoplastic lesions treated by EFTR. RESULTS: EFTR was technically feasible in 28/30 (93,3%) of the cases with an R0 resection in 24/30 (80%) and a median procedure time (marking to full thickness resection) of 34,5 min (11–120). After the first 15 procedures, the per-protocol rate increased from 13/15 to 15/15 and the R0 resection rate increased from 9/15 (69,2%) to 15/15 (100,0%; p < 0.01). One patient suffered from a delayed perforation the day after the procedure and needed emergency surgery (3,6%). Minor bleeding occurred in 3/28 patients (10,7%) and post-interventional fever in one patient (3,6%). The 30-day mortality rate was 0%. CONCLUSIONS: EFTR with an over-the-scope device is a useful method for endoscopic resection of difficult to treat recurrent or residual colorectal neoplasia after previous endoscopic therapy. High R0 resection rates were observed after a relatively short learning curve. The complication rate in this series seems acceptable given the complexity of the resected lesions. BioMed Central 2019-07-10 /pmc/articles/PMC6617569/ /pubmed/31291893 http://dx.doi.org/10.1186/s12876-019-1043-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
von Helden, Annabell
Hildenbrand, Ralf
Sido, Bernd
Dumoulin, Franz Ludwig
Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
title Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
title_full Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
title_fullStr Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
title_full_unstemmed Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
title_short Endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
title_sort endoscopic full-thickness resection using an over-the-scope device for treatment of recurrent / residual colorectal neoplasia: a single-center case series
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6617569/
https://www.ncbi.nlm.nih.gov/pubmed/31291893
http://dx.doi.org/10.1186/s12876-019-1043-8
work_keys_str_mv AT vonheldenannabell endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries
AT hildenbrandralf endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries
AT sidobernd endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries
AT dumoulinfranzludwig endoscopicfullthicknessresectionusinganoverthescopedevicefortreatmentofrecurrentresidualcolorectalneoplasiaasinglecentercaseseries