Cargando…
A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619810/ https://www.ncbi.nlm.nih.gov/pubmed/31291361 http://dx.doi.org/10.1371/journal.pone.0219605 |
_version_ | 1783433964525977600 |
---|---|
author | Jiang, Kai Ferguson, Christopher M. Abumoawad, Abdelrhman Saad, Ahmed Textor, Stephen C. Lerman, Lilach O. |
author_facet | Jiang, Kai Ferguson, Christopher M. Abumoawad, Abdelrhman Saad, Ahmed Textor, Stephen C. Lerman, Lilach O. |
author_sort | Jiang, Kai |
collection | PubMed |
description | OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Thirty-eight patients with essential hypertension (EH, n = 13) or atherosclerotic renal artery stenosis (ARAS, n = 25) underwent renal DCE-CT for GFR and perfusion measurement using a modified two-compartment model. Iothalamate clearance was used to measure reference total GFR, which was apportioned into single-kidney GFR by renal blood flow. Renal perfusion was also calculated using a conventional deconvolution algorithm. Validation of GFR and perfusion and inter-observer reproducibility, were conducted by using the Pearson correlation and Bland-Altman analysis. RESULTS: Both the two-compartment model and iothalamate clearance detected in ARAS patients lower GFR in the stenotic compared to the contralateral and EH kidneys. GFRs measured by DCE-CT and iothalamate clearance showed a close match (r = 0.94, P<0.001, and mean difference 2.5±12.2mL/min). Inter-observer bias and variation in model-derived GFR (r = 0.97, P<0.001; mean difference, 0.3±7.7mL/min) were minimal. Renal perfusion by deconvolution agreed well with that by the compartment model when the blood transit delay from abdominal aorta to kidney was negligible. CONCLUSION: The proposed two-compartment model faithfully depicts contrast dynamics using DCE-CT and may provide a reliable tool for measuring human single-kidney GFR and perfusion. |
format | Online Article Text |
id | pubmed-6619810 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-66198102019-07-25 A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography Jiang, Kai Ferguson, Christopher M. Abumoawad, Abdelrhman Saad, Ahmed Textor, Stephen C. Lerman, Lilach O. PLoS One Research Article OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Thirty-eight patients with essential hypertension (EH, n = 13) or atherosclerotic renal artery stenosis (ARAS, n = 25) underwent renal DCE-CT for GFR and perfusion measurement using a modified two-compartment model. Iothalamate clearance was used to measure reference total GFR, which was apportioned into single-kidney GFR by renal blood flow. Renal perfusion was also calculated using a conventional deconvolution algorithm. Validation of GFR and perfusion and inter-observer reproducibility, were conducted by using the Pearson correlation and Bland-Altman analysis. RESULTS: Both the two-compartment model and iothalamate clearance detected in ARAS patients lower GFR in the stenotic compared to the contralateral and EH kidneys. GFRs measured by DCE-CT and iothalamate clearance showed a close match (r = 0.94, P<0.001, and mean difference 2.5±12.2mL/min). Inter-observer bias and variation in model-derived GFR (r = 0.97, P<0.001; mean difference, 0.3±7.7mL/min) were minimal. Renal perfusion by deconvolution agreed well with that by the compartment model when the blood transit delay from abdominal aorta to kidney was negligible. CONCLUSION: The proposed two-compartment model faithfully depicts contrast dynamics using DCE-CT and may provide a reliable tool for measuring human single-kidney GFR and perfusion. Public Library of Science 2019-07-10 /pmc/articles/PMC6619810/ /pubmed/31291361 http://dx.doi.org/10.1371/journal.pone.0219605 Text en © 2019 Jiang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Jiang, Kai Ferguson, Christopher M. Abumoawad, Abdelrhman Saad, Ahmed Textor, Stephen C. Lerman, Lilach O. A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
title | A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
title_full | A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
title_fullStr | A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
title_full_unstemmed | A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
title_short | A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
title_sort | modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619810/ https://www.ncbi.nlm.nih.gov/pubmed/31291361 http://dx.doi.org/10.1371/journal.pone.0219605 |
work_keys_str_mv | AT jiangkai amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT fergusonchristopherm amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT abumoawadabdelrhman amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT saadahmed amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT textorstephenc amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT lermanlilacho amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT jiangkai modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT fergusonchristopherm modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT abumoawadabdelrhman modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT saadahmed modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT textorstephenc modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography AT lermanlilacho modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography |