Cargando…

A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography

OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Kai, Ferguson, Christopher M., Abumoawad, Abdelrhman, Saad, Ahmed, Textor, Stephen C., Lerman, Lilach O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619810/
https://www.ncbi.nlm.nih.gov/pubmed/31291361
http://dx.doi.org/10.1371/journal.pone.0219605
_version_ 1783433964525977600
author Jiang, Kai
Ferguson, Christopher M.
Abumoawad, Abdelrhman
Saad, Ahmed
Textor, Stephen C.
Lerman, Lilach O.
author_facet Jiang, Kai
Ferguson, Christopher M.
Abumoawad, Abdelrhman
Saad, Ahmed
Textor, Stephen C.
Lerman, Lilach O.
author_sort Jiang, Kai
collection PubMed
description OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Thirty-eight patients with essential hypertension (EH, n = 13) or atherosclerotic renal artery stenosis (ARAS, n = 25) underwent renal DCE-CT for GFR and perfusion measurement using a modified two-compartment model. Iothalamate clearance was used to measure reference total GFR, which was apportioned into single-kidney GFR by renal blood flow. Renal perfusion was also calculated using a conventional deconvolution algorithm. Validation of GFR and perfusion and inter-observer reproducibility, were conducted by using the Pearson correlation and Bland-Altman analysis. RESULTS: Both the two-compartment model and iothalamate clearance detected in ARAS patients lower GFR in the stenotic compared to the contralateral and EH kidneys. GFRs measured by DCE-CT and iothalamate clearance showed a close match (r = 0.94, P<0.001, and mean difference 2.5±12.2mL/min). Inter-observer bias and variation in model-derived GFR (r = 0.97, P<0.001; mean difference, 0.3±7.7mL/min) were minimal. Renal perfusion by deconvolution agreed well with that by the compartment model when the blood transit delay from abdominal aorta to kidney was negligible. CONCLUSION: The proposed two-compartment model faithfully depicts contrast dynamics using DCE-CT and may provide a reliable tool for measuring human single-kidney GFR and perfusion.
format Online
Article
Text
id pubmed-6619810
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-66198102019-07-25 A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography Jiang, Kai Ferguson, Christopher M. Abumoawad, Abdelrhman Saad, Ahmed Textor, Stephen C. Lerman, Lilach O. PLoS One Research Article OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Thirty-eight patients with essential hypertension (EH, n = 13) or atherosclerotic renal artery stenosis (ARAS, n = 25) underwent renal DCE-CT for GFR and perfusion measurement using a modified two-compartment model. Iothalamate clearance was used to measure reference total GFR, which was apportioned into single-kidney GFR by renal blood flow. Renal perfusion was also calculated using a conventional deconvolution algorithm. Validation of GFR and perfusion and inter-observer reproducibility, were conducted by using the Pearson correlation and Bland-Altman analysis. RESULTS: Both the two-compartment model and iothalamate clearance detected in ARAS patients lower GFR in the stenotic compared to the contralateral and EH kidneys. GFRs measured by DCE-CT and iothalamate clearance showed a close match (r = 0.94, P<0.001, and mean difference 2.5±12.2mL/min). Inter-observer bias and variation in model-derived GFR (r = 0.97, P<0.001; mean difference, 0.3±7.7mL/min) were minimal. Renal perfusion by deconvolution agreed well with that by the compartment model when the blood transit delay from abdominal aorta to kidney was negligible. CONCLUSION: The proposed two-compartment model faithfully depicts contrast dynamics using DCE-CT and may provide a reliable tool for measuring human single-kidney GFR and perfusion. Public Library of Science 2019-07-10 /pmc/articles/PMC6619810/ /pubmed/31291361 http://dx.doi.org/10.1371/journal.pone.0219605 Text en © 2019 Jiang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Jiang, Kai
Ferguson, Christopher M.
Abumoawad, Abdelrhman
Saad, Ahmed
Textor, Stephen C.
Lerman, Lilach O.
A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
title A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
title_full A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
title_fullStr A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
title_full_unstemmed A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
title_short A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
title_sort modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619810/
https://www.ncbi.nlm.nih.gov/pubmed/31291361
http://dx.doi.org/10.1371/journal.pone.0219605
work_keys_str_mv AT jiangkai amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT fergusonchristopherm amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT abumoawadabdelrhman amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT saadahmed amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT textorstephenc amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT lermanlilacho amodifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT jiangkai modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT fergusonchristopherm modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT abumoawadabdelrhman modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT saadahmed modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT textorstephenc modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography
AT lermanlilacho modifiedtwocompartmentmodelformeasurementofrenalfunctionusingdynamiccontrastenhancedcomputedtomography