Cargando…

A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography

OBJECTIVES: To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). METHODS: This prospective study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Kai, Ferguson, Christopher M., Abumoawad, Abdelrhman, Saad, Ahmed, Textor, Stephen C., Lerman, Lilach O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619810/
https://www.ncbi.nlm.nih.gov/pubmed/31291361
http://dx.doi.org/10.1371/journal.pone.0219605

Ejemplares similares