Cargando…

Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique

INTRODUCTION: Wrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily energy expenditure, including any change induced by long-term participation i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kinnunen, Hannu, Häkkinen, Keijo, Schumann, Moritz, Karavirta, Laura, Westerterp, Klaas R., Kyröläinen, Heikki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619827/
https://www.ncbi.nlm.nih.gov/pubmed/31291373
http://dx.doi.org/10.1371/journal.pone.0219563
_version_ 1783433968609132544
author Kinnunen, Hannu
Häkkinen, Keijo
Schumann, Moritz
Karavirta, Laura
Westerterp, Klaas R.
Kyröläinen, Heikki
author_facet Kinnunen, Hannu
Häkkinen, Keijo
Schumann, Moritz
Karavirta, Laura
Westerterp, Klaas R.
Kyröläinen, Heikki
author_sort Kinnunen, Hannu
collection PubMed
description INTRODUCTION: Wrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily energy expenditure, including any change induced by long-term participation in endurance and strength training. Supplemental heart rate monitoring during weekly exercise was also investigated. METHODS: A 13-day doubly labeled water (DLW) measurement of total energy expenditure (TEE) was performed twice in healthy male subjects: during two last weeks of a 12-week Control period (n = 15) and during two last weeks of a 12-week combined strength and aerobic Training period (n = 13). Resting energy expenditure was estimated using two equations: one with body weight and age, and another one with fat-free mass. TEE and activity induced energy expenditure (AEE) were determined from motion sensor alone, and from motions sensor combined with heart rate monitor, the latter being worn during exercise only. RESULTS: When body weight and age were used in the calculation of resting energy expenditure, the motion sensor data alone explained 78% and 62% of the variation in TEE assessed by DLW at the end of Control and Training periods, respectively, with a bias of +1.75 (p <.001) and +1.19 MJ/day (p = .002). When exercise heart rate data was added to the model, the combined wearable device approach explained 85% and 70% of the variation in TEE assessed by DLW with a bias of +1.89 and +1.75 MJ/day (p <.001 for both). While significant increases in TEE and AEE were detected by all methods as a result of participation in regular training, motion sensor approach underestimated the change measured by DLW: +1.13±0.66 by DLW, +0.59±0.69 (p = .004) by motion sensor, and +0.98±0.70 MJ/day by combination of motion sensor and heart rate. Use of fat-free mass in the estimation of resting energy expenditure removed the biases between the wearable device estimations and the golden standard reference method of TEE and demonstrated a training-induced increase in resting energy expenditure by +0.18±0.13 MJ/day (p <.001). CONCLUSIONS: Wrist motion sensor combined with a heart rate monitor during exercise sessions, showed high agreement with the golden standard measurement of daily TEE and its change induced by participation in a long-term training protocol. The positive findings concerning the validity, especially the ability to follow-up the change associated with a lifestyle modification, can be considered significant because they partially determine the feasibility of wearable devices as quantifiers of health-related behavior.
format Online
Article
Text
id pubmed-6619827
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-66198272019-07-25 Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique Kinnunen, Hannu Häkkinen, Keijo Schumann, Moritz Karavirta, Laura Westerterp, Klaas R. Kyröläinen, Heikki PLoS One Research Article INTRODUCTION: Wrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily energy expenditure, including any change induced by long-term participation in endurance and strength training. Supplemental heart rate monitoring during weekly exercise was also investigated. METHODS: A 13-day doubly labeled water (DLW) measurement of total energy expenditure (TEE) was performed twice in healthy male subjects: during two last weeks of a 12-week Control period (n = 15) and during two last weeks of a 12-week combined strength and aerobic Training period (n = 13). Resting energy expenditure was estimated using two equations: one with body weight and age, and another one with fat-free mass. TEE and activity induced energy expenditure (AEE) were determined from motion sensor alone, and from motions sensor combined with heart rate monitor, the latter being worn during exercise only. RESULTS: When body weight and age were used in the calculation of resting energy expenditure, the motion sensor data alone explained 78% and 62% of the variation in TEE assessed by DLW at the end of Control and Training periods, respectively, with a bias of +1.75 (p <.001) and +1.19 MJ/day (p = .002). When exercise heart rate data was added to the model, the combined wearable device approach explained 85% and 70% of the variation in TEE assessed by DLW with a bias of +1.89 and +1.75 MJ/day (p <.001 for both). While significant increases in TEE and AEE were detected by all methods as a result of participation in regular training, motion sensor approach underestimated the change measured by DLW: +1.13±0.66 by DLW, +0.59±0.69 (p = .004) by motion sensor, and +0.98±0.70 MJ/day by combination of motion sensor and heart rate. Use of fat-free mass in the estimation of resting energy expenditure removed the biases between the wearable device estimations and the golden standard reference method of TEE and demonstrated a training-induced increase in resting energy expenditure by +0.18±0.13 MJ/day (p <.001). CONCLUSIONS: Wrist motion sensor combined with a heart rate monitor during exercise sessions, showed high agreement with the golden standard measurement of daily TEE and its change induced by participation in a long-term training protocol. The positive findings concerning the validity, especially the ability to follow-up the change associated with a lifestyle modification, can be considered significant because they partially determine the feasibility of wearable devices as quantifiers of health-related behavior. Public Library of Science 2019-07-10 /pmc/articles/PMC6619827/ /pubmed/31291373 http://dx.doi.org/10.1371/journal.pone.0219563 Text en © 2019 Kinnunen et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kinnunen, Hannu
Häkkinen, Keijo
Schumann, Moritz
Karavirta, Laura
Westerterp, Klaas R.
Kyröläinen, Heikki
Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
title Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
title_full Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
title_fullStr Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
title_full_unstemmed Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
title_short Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
title_sort training-induced changes in daily energy expenditure: methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6619827/
https://www.ncbi.nlm.nih.gov/pubmed/31291373
http://dx.doi.org/10.1371/journal.pone.0219563
work_keys_str_mv AT kinnunenhannu traininginducedchangesindailyenergyexpendituremethodologicalevaluationusingwristwornaccelerometerheartratemonitoranddoublylabeledwatertechnique
AT hakkinenkeijo traininginducedchangesindailyenergyexpendituremethodologicalevaluationusingwristwornaccelerometerheartratemonitoranddoublylabeledwatertechnique
AT schumannmoritz traininginducedchangesindailyenergyexpendituremethodologicalevaluationusingwristwornaccelerometerheartratemonitoranddoublylabeledwatertechnique
AT karavirtalaura traininginducedchangesindailyenergyexpendituremethodologicalevaluationusingwristwornaccelerometerheartratemonitoranddoublylabeledwatertechnique
AT westerterpklaasr traininginducedchangesindailyenergyexpendituremethodologicalevaluationusingwristwornaccelerometerheartratemonitoranddoublylabeledwatertechnique
AT kyrolainenheikki traininginducedchangesindailyenergyexpendituremethodologicalevaluationusingwristwornaccelerometerheartratemonitoranddoublylabeledwatertechnique