Cargando…

The frequency of non-pathologically thin corneas in young healthy adults

Purpose: Measurement of normal corneal thickness and corneal epithelial thickness is important in keratorefractive surgery, glaucoma, following extended contact lens wear, and in patients with corneal disease. Clinically, a central corneal thickness less than 500 µm is considered to be moderately-to...

Descripción completa

Detalles Bibliográficos
Autores principales: Rashdan, Hannah, Shah, Manali, Robertson, Danielle M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6628863/
https://www.ncbi.nlm.nih.gov/pubmed/31371912
http://dx.doi.org/10.2147/OPTH.S188935
_version_ 1783435024278749184
author Rashdan, Hannah
Shah, Manali
Robertson, Danielle M
author_facet Rashdan, Hannah
Shah, Manali
Robertson, Danielle M
author_sort Rashdan, Hannah
collection PubMed
description Purpose: Measurement of normal corneal thickness and corneal epithelial thickness is important in keratorefractive surgery, glaucoma, following extended contact lens wear, and in patients with corneal disease. Clinically, a central corneal thickness less than 500 µm is considered to be moderately-to-extremely thin. The purpose of this study was to compare biological differences in patients with clinically thin compared to normal corneal thickness values in healthy young adults using Fourier domain optical coherence tomography. Patients and methods: In total, 168 eyes from 84 patients aged 19–38 years were scanned using an Avanti optical coherence tomographer. To eliminate circadian effects on corneal thickness, all patients were scanned within a 4-hour window. Corneal thickness was measured across the central 6 mm of the cornea. Total central corneal thickness, corneal epithelial thickness, and corneal stromal thickness were compared between males and females and tested for correlations with age, use of systemic hormones, degree of myopia, and corneal curvature. Results: The average central corneal thickness for males and females was 540.5±32.0 μm and 525.2±33.0 μm, respectively (P=0.020). Thirty-eight eyes had corneal thickness measurements below 500 µm; 12% (6 eyes) from males and 28% (16 eyes) from females (P=0.008). All women with corneas below 500 μm were bilaterally thin. This finding differed for men. Corneal thinning was not associated with age, use of systemic hormones, or degree of myopia. Females had steeper keratometry (K) readings (P=0.01 for flat K, P=0.002 for steep K) than males. No differences in layer offset values between normal thickness corneas and thin corneas were evident, suggesting that the reduced thickness was not pathological. Conclusion: The results of this study indicate that a subpopulation of healthy young adults have non-pathologically thin corneas, well below 500 μm; and that these thinner corneas are more frequent in females. This underscores the importance of accurate corneal thickness measurements prior to keratorefractive surgery and when evaluating intraocular pressure in glaucoma.
format Online
Article
Text
id pubmed-6628863
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-66288632019-08-01 The frequency of non-pathologically thin corneas in young healthy adults Rashdan, Hannah Shah, Manali Robertson, Danielle M Clin Ophthalmol Original Research Purpose: Measurement of normal corneal thickness and corneal epithelial thickness is important in keratorefractive surgery, glaucoma, following extended contact lens wear, and in patients with corneal disease. Clinically, a central corneal thickness less than 500 µm is considered to be moderately-to-extremely thin. The purpose of this study was to compare biological differences in patients with clinically thin compared to normal corneal thickness values in healthy young adults using Fourier domain optical coherence tomography. Patients and methods: In total, 168 eyes from 84 patients aged 19–38 years were scanned using an Avanti optical coherence tomographer. To eliminate circadian effects on corneal thickness, all patients were scanned within a 4-hour window. Corneal thickness was measured across the central 6 mm of the cornea. Total central corneal thickness, corneal epithelial thickness, and corneal stromal thickness were compared between males and females and tested for correlations with age, use of systemic hormones, degree of myopia, and corneal curvature. Results: The average central corneal thickness for males and females was 540.5±32.0 μm and 525.2±33.0 μm, respectively (P=0.020). Thirty-eight eyes had corneal thickness measurements below 500 µm; 12% (6 eyes) from males and 28% (16 eyes) from females (P=0.008). All women with corneas below 500 μm were bilaterally thin. This finding differed for men. Corneal thinning was not associated with age, use of systemic hormones, or degree of myopia. Females had steeper keratometry (K) readings (P=0.01 for flat K, P=0.002 for steep K) than males. No differences in layer offset values between normal thickness corneas and thin corneas were evident, suggesting that the reduced thickness was not pathological. Conclusion: The results of this study indicate that a subpopulation of healthy young adults have non-pathologically thin corneas, well below 500 μm; and that these thinner corneas are more frequent in females. This underscores the importance of accurate corneal thickness measurements prior to keratorefractive surgery and when evaluating intraocular pressure in glaucoma. Dove 2019-07-09 /pmc/articles/PMC6628863/ /pubmed/31371912 http://dx.doi.org/10.2147/OPTH.S188935 Text en © 2019 Rashdan et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Rashdan, Hannah
Shah, Manali
Robertson, Danielle M
The frequency of non-pathologically thin corneas in young healthy adults
title The frequency of non-pathologically thin corneas in young healthy adults
title_full The frequency of non-pathologically thin corneas in young healthy adults
title_fullStr The frequency of non-pathologically thin corneas in young healthy adults
title_full_unstemmed The frequency of non-pathologically thin corneas in young healthy adults
title_short The frequency of non-pathologically thin corneas in young healthy adults
title_sort frequency of non-pathologically thin corneas in young healthy adults
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6628863/
https://www.ncbi.nlm.nih.gov/pubmed/31371912
http://dx.doi.org/10.2147/OPTH.S188935
work_keys_str_mv AT rashdanhannah thefrequencyofnonpathologicallythincorneasinyounghealthyadults
AT shahmanali thefrequencyofnonpathologicallythincorneasinyounghealthyadults
AT robertsondaniellem thefrequencyofnonpathologicallythincorneasinyounghealthyadults
AT rashdanhannah frequencyofnonpathologicallythincorneasinyounghealthyadults
AT shahmanali frequencyofnonpathologicallythincorneasinyounghealthyadults
AT robertsondaniellem frequencyofnonpathologicallythincorneasinyounghealthyadults