Cargando…

SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY

The aim of the study was to assess biometric factor aberrations and differences among groups of eyes with cataract and pseudoexfoliative syndrome, cataract and pseudoexfoliative glaucoma, and cataract and primary open-angle glaucoma (POAG), and to determine biometric factors of the eye specific for...

Descripción completa

Detalles Bibliográficos
Autores principales: Janjetović, Željka, Bušić, Mladen, Bosnar, Damir, Barać, Josip, Genda, Ivanka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sestre Milosrdnice University Hospital and Institute of Clinical Medical Research, Vinogradska cesta c. 29 Zagreb 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629193/
https://www.ncbi.nlm.nih.gov/pubmed/31363329
http://dx.doi.org/10.20471/acc.2019.58.01.11
_version_ 1783435065731055616
author Janjetović, Željka
Bušić, Mladen
Bosnar, Damir
Barać, Josip
Genda, Ivanka
author_facet Janjetović, Željka
Bušić, Mladen
Bosnar, Damir
Barać, Josip
Genda, Ivanka
author_sort Janjetović, Željka
collection PubMed
description The aim of the study was to assess biometric factor aberrations and differences among groups of eyes with cataract and pseudoexfoliative syndrome, cataract and pseudoexfoliative glaucoma, and cataract and primary open-angle glaucoma (POAG), and to determine biometric factors of the eye specific for the group of glaucomatous patients with pseudoexfoliative syndrome by use of optical low-coherence reflectometry. This retrospective study included 72 patients, and the study sample of 102 eyes was divided into the following three groups according to diagnosis: 29 eyes with pseudoexfoliative syndrome and cataract; 36 eyes with POAG and cataract; and 37 eyes with pseudoexfoliative glaucoma and cataract. Data on biometric measurements (central corneal thickness, pupillary diameter, anterior chamber depth, lens thickness, axial length, retinal thickness, astigmatism and white-to-white) obtained by use of optical low-coherence reflectometry on a Lenstar LS 900® (Haag-Streit International) were collected and analyzed by thorough survey of medical documentation of patients scheduled for cataract surgery at Department of Ophthalmology, Sveti Duh University Hospital in Zagreb, Croatia. Comparative analysis of the groups yielded statistically significant differences in central corneal thickness (F2/99=7.066; p=0.001) and lens thickness (F2/96=5.133; p=0.008). The group of eyes diagnosed with pseudoexfoliative glaucoma and cataract had a significantly thinner cornea as compared with the other two groups and a significantly thicker lens as compared with the group of eyes with POAG and cataract. In conclusion, optical low-coherence reflectometry revealed differences in biometric factors among the three groups of eyes, with a statistically significantly thinner cornea and thicker lens in the group of glaucomatous patients with pseudoexfoliative syndrome.
format Online
Article
Text
id pubmed-6629193
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Sestre Milosrdnice University Hospital and Institute of Clinical Medical Research, Vinogradska cesta c. 29 Zagreb
record_format MEDLINE/PubMed
spelling pubmed-66291932019-07-30 SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY Janjetović, Željka Bušić, Mladen Bosnar, Damir Barać, Josip Genda, Ivanka Acta Clin Croat Original Scientific Papers The aim of the study was to assess biometric factor aberrations and differences among groups of eyes with cataract and pseudoexfoliative syndrome, cataract and pseudoexfoliative glaucoma, and cataract and primary open-angle glaucoma (POAG), and to determine biometric factors of the eye specific for the group of glaucomatous patients with pseudoexfoliative syndrome by use of optical low-coherence reflectometry. This retrospective study included 72 patients, and the study sample of 102 eyes was divided into the following three groups according to diagnosis: 29 eyes with pseudoexfoliative syndrome and cataract; 36 eyes with POAG and cataract; and 37 eyes with pseudoexfoliative glaucoma and cataract. Data on biometric measurements (central corneal thickness, pupillary diameter, anterior chamber depth, lens thickness, axial length, retinal thickness, astigmatism and white-to-white) obtained by use of optical low-coherence reflectometry on a Lenstar LS 900® (Haag-Streit International) were collected and analyzed by thorough survey of medical documentation of patients scheduled for cataract surgery at Department of Ophthalmology, Sveti Duh University Hospital in Zagreb, Croatia. Comparative analysis of the groups yielded statistically significant differences in central corneal thickness (F2/99=7.066; p=0.001) and lens thickness (F2/96=5.133; p=0.008). The group of eyes diagnosed with pseudoexfoliative glaucoma and cataract had a significantly thinner cornea as compared with the other two groups and a significantly thicker lens as compared with the group of eyes with POAG and cataract. In conclusion, optical low-coherence reflectometry revealed differences in biometric factors among the three groups of eyes, with a statistically significantly thinner cornea and thicker lens in the group of glaucomatous patients with pseudoexfoliative syndrome. Sestre Milosrdnice University Hospital and Institute of Clinical Medical Research, Vinogradska cesta c. 29 Zagreb 2019-03 /pmc/articles/PMC6629193/ /pubmed/31363329 http://dx.doi.org/10.20471/acc.2019.58.01.11 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND) 4.0 License.
spellingShingle Original Scientific Papers
Janjetović, Željka
Bušić, Mladen
Bosnar, Damir
Barać, Josip
Genda, Ivanka
SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY
title SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY
title_full SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY
title_fullStr SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY
title_full_unstemmed SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY
title_short SPECIFIC CHARACTERISTICS OF OCULAR BIOMETRIC FACTORS IN GLAUCOMATOUS PATIENTS WITH PSEUDOEXFOLIATIVE SYNDROME AS MEASURED BY OPTICAL LOW-COHERENCE REFLECTOMETRY
title_sort specific characteristics of ocular biometric factors in glaucomatous patients with pseudoexfoliative syndrome as measured by optical low-coherence reflectometry
topic Original Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629193/
https://www.ncbi.nlm.nih.gov/pubmed/31363329
http://dx.doi.org/10.20471/acc.2019.58.01.11
work_keys_str_mv AT janjetoviczeljka specificcharacteristicsofocularbiometricfactorsinglaucomatouspatientswithpseudoexfoliativesyndromeasmeasuredbyopticallowcoherencereflectometry
AT busicmladen specificcharacteristicsofocularbiometricfactorsinglaucomatouspatientswithpseudoexfoliativesyndromeasmeasuredbyopticallowcoherencereflectometry
AT bosnardamir specificcharacteristicsofocularbiometricfactorsinglaucomatouspatientswithpseudoexfoliativesyndromeasmeasuredbyopticallowcoherencereflectometry
AT baracjosip specificcharacteristicsofocularbiometricfactorsinglaucomatouspatientswithpseudoexfoliativesyndromeasmeasuredbyopticallowcoherencereflectometry
AT gendaivanka specificcharacteristicsofocularbiometricfactorsinglaucomatouspatientswithpseudoexfoliativesyndromeasmeasuredbyopticallowcoherencereflectometry