Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices
OBJECTIVE: How to increase the long-term retention rate of autologous fat grafting has been widely discussed. This study aimed to evaluate long-term fat graft retention rates for the most widely used fat processing methods in the area of facial esthetic surgery, including centrifugation, filtration,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629306/ https://www.ncbi.nlm.nih.gov/pubmed/30628961 http://dx.doi.org/10.1097/CM9.0000000000000016 |
_version_ | 1783435082582720512 |
---|---|
author | Wang, Guan-Hui-Er Zhao, Jian-Fang Xue, Hong-Yu Li, Dong |
author_facet | Wang, Guan-Hui-Er Zhao, Jian-Fang Xue, Hong-Yu Li, Dong |
author_sort | Wang, Guan-Hui-Er |
collection | PubMed |
description | OBJECTIVE: How to increase the long-term retention rate of autologous fat grafting has been widely discussed. This study aimed to evaluate long-term fat graft retention rates for the most widely used fat processing methods in the area of facial esthetic surgery, including centrifugation, filtration, and sedimentation, using three-dimensional (3D) imaging. DATA SOURCES: PubMed, Embase, Wiley/Cochrane Library, and Web of Science databases were comprehensively searched from inception to July 2018 according to the guidelines of the American Society of Plastic Surgeons Fat Graft Task Force Assessment Methodology. STUDY SELECTION: Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, follow-up devices, fat grafting techniques, and clinical outcomes. Patient cohorts were pooled, and fat graft retention rates were calculated. Complications were summarized according to different clinical characteristics. RESULTS: Of 77 articles, 10 clinical studies met the inclusion criteria and reported quantified measurement outcomes with 3D imaging which provide precise volumetric data with approximately 2% standard deviation compared to real volumes. Data of 515 patients were included. Fat grafting retention varied from 21% to 82%. We found filtration and centrifugation techniques could result in better retention outcomes. However, retention varied within each processing technique, with no significant difference among the 3 techniques. Twenty-two complications were reported among 515 patients, including donor-site hematoma (1 case), mild post-operative erythema (2 cases), mild volumetric asymmetries (2 cases), chronic edema (2 cases), overcorrection (2 cases), skin irregularity (6 cases), and headache or dysesthesia (7 cases). CONCLUSIONS: Filtration and centrifugation techniques may result in better fat grafting retention outcomes than gravity sedimentation; however, more accurate statistical evidence is needed. Controversies continue to exist with respect to the performance of the different fat-processing techniques in fat graft retention. |
format | Online Article Text |
id | pubmed-6629306 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-66293062019-07-22 Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices Wang, Guan-Hui-Er Zhao, Jian-Fang Xue, Hong-Yu Li, Dong Chin Med J (Engl) Review Article OBJECTIVE: How to increase the long-term retention rate of autologous fat grafting has been widely discussed. This study aimed to evaluate long-term fat graft retention rates for the most widely used fat processing methods in the area of facial esthetic surgery, including centrifugation, filtration, and sedimentation, using three-dimensional (3D) imaging. DATA SOURCES: PubMed, Embase, Wiley/Cochrane Library, and Web of Science databases were comprehensively searched from inception to July 2018 according to the guidelines of the American Society of Plastic Surgeons Fat Graft Task Force Assessment Methodology. STUDY SELECTION: Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, follow-up devices, fat grafting techniques, and clinical outcomes. Patient cohorts were pooled, and fat graft retention rates were calculated. Complications were summarized according to different clinical characteristics. RESULTS: Of 77 articles, 10 clinical studies met the inclusion criteria and reported quantified measurement outcomes with 3D imaging which provide precise volumetric data with approximately 2% standard deviation compared to real volumes. Data of 515 patients were included. Fat grafting retention varied from 21% to 82%. We found filtration and centrifugation techniques could result in better retention outcomes. However, retention varied within each processing technique, with no significant difference among the 3 techniques. Twenty-two complications were reported among 515 patients, including donor-site hematoma (1 case), mild post-operative erythema (2 cases), mild volumetric asymmetries (2 cases), chronic edema (2 cases), overcorrection (2 cases), skin irregularity (6 cases), and headache or dysesthesia (7 cases). CONCLUSIONS: Filtration and centrifugation techniques may result in better fat grafting retention outcomes than gravity sedimentation; however, more accurate statistical evidence is needed. Controversies continue to exist with respect to the performance of the different fat-processing techniques in fat graft retention. Wolters Kluwer Health 2019-01-05 2019-01-05 /pmc/articles/PMC6629306/ /pubmed/30628961 http://dx.doi.org/10.1097/CM9.0000000000000016 Text en Copyright © 2018 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | Review Article Wang, Guan-Hui-Er Zhao, Jian-Fang Xue, Hong-Yu Li, Dong Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
title | Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
title_full | Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
title_fullStr | Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
title_full_unstemmed | Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
title_short | Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
title_sort | facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629306/ https://www.ncbi.nlm.nih.gov/pubmed/30628961 http://dx.doi.org/10.1097/CM9.0000000000000016 |
work_keys_str_mv | AT wangguanhuier facialaestheticfatgraftretentionratesafterfiltrationcentrifugationorsedimentationprocessingtechniquesmeasuredusingthreedimensionalsurfaceimagingdevices AT zhaojianfang facialaestheticfatgraftretentionratesafterfiltrationcentrifugationorsedimentationprocessingtechniquesmeasuredusingthreedimensionalsurfaceimagingdevices AT xuehongyu facialaestheticfatgraftretentionratesafterfiltrationcentrifugationorsedimentationprocessingtechniquesmeasuredusingthreedimensionalsurfaceimagingdevices AT lidong facialaestheticfatgraftretentionratesafterfiltrationcentrifugationorsedimentationprocessingtechniquesmeasuredusingthreedimensionalsurfaceimagingdevices |